Novel flexible endoscope concept with swiveling camera tip

Endoscopy is an important modality in medical imaging. Thin flexible endoscopes are for example used to examine the upper airways, for gastroscopy procedures or lung inspection. With standard flexible endoscopes one can change the direction of view by bending the tip with the disadvantage of large s...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Boese Axel, Arens Christoph, Friebe Michael
Formato: article
Lenguaje:EN
Publicado: De Gruyter 2020
Materias:
R
Acceso en línea:https://doaj.org/article/3257ac904b404b6db51af41813cf98e6
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:3257ac904b404b6db51af41813cf98e6
record_format dspace
spelling oai:doaj.org-article:3257ac904b404b6db51af41813cf98e62021-12-05T14:10:42ZNovel flexible endoscope concept with swiveling camera tip2364-550410.1515/cdbme-2020-3073https://doaj.org/article/3257ac904b404b6db51af41813cf98e62020-09-01T00:00:00Zhttps://doi.org/10.1515/cdbme-2020-3073https://doaj.org/toc/2364-5504Endoscopy is an important modality in medical imaging. Thin flexible endoscopes are for example used to examine the upper airways, for gastroscopy procedures or lung inspection. With standard flexible endoscopes one can change the direction of view by bending the tip with the disadvantage of large space required due to the bending radius. With first experiences of a concept of a moveable camera head on the tip of rigid endoscopes, we now propose a novel design employing a swiveling camera for flexible endoscopes. This concept is based on the use of a shape memory wire used to control the movement of the camera, a flexible plastic flap joint for tight rotation and flexible printed circuits for the electronic connection. The prototype was realized in a first low cost setup using a 5,5 mm HD chip on the tip camera with LED light. The motion and imaging performance of the prototype allowed swiveling of the camera on the endoscope tip from straight view to 100° side view. The space needed in fully rotation was limited to 9mm with an overall diameter of the endoscope in straight view of only 5,6mm, but could even be further reduced in a more professional setup. The image quality is good, but close-up views appear blurry due to the fixed focus point of the low-cost camera. The presented steering concept of the camera is promising, as it could potentially improve imaging of narrow cavities using flexible endoscopes. Especially for “in office” examinations this principle could add value to diagnosis and patient comfort.Boese AxelArens ChristophFriebe MichaelDe Gruyterarticleflexible endoscopybending radiusshape memorychip on the tipsteeringMedicineRENCurrent Directions in Biomedical Engineering, Vol 6, Iss 3, Pp 288-291 (2020)
institution DOAJ
collection DOAJ
language EN
topic flexible endoscopy
bending radius
shape memory
chip on the tip
steering
Medicine
R
spellingShingle flexible endoscopy
bending radius
shape memory
chip on the tip
steering
Medicine
R
Boese Axel
Arens Christoph
Friebe Michael
Novel flexible endoscope concept with swiveling camera tip
description Endoscopy is an important modality in medical imaging. Thin flexible endoscopes are for example used to examine the upper airways, for gastroscopy procedures or lung inspection. With standard flexible endoscopes one can change the direction of view by bending the tip with the disadvantage of large space required due to the bending radius. With first experiences of a concept of a moveable camera head on the tip of rigid endoscopes, we now propose a novel design employing a swiveling camera for flexible endoscopes. This concept is based on the use of a shape memory wire used to control the movement of the camera, a flexible plastic flap joint for tight rotation and flexible printed circuits for the electronic connection. The prototype was realized in a first low cost setup using a 5,5 mm HD chip on the tip camera with LED light. The motion and imaging performance of the prototype allowed swiveling of the camera on the endoscope tip from straight view to 100° side view. The space needed in fully rotation was limited to 9mm with an overall diameter of the endoscope in straight view of only 5,6mm, but could even be further reduced in a more professional setup. The image quality is good, but close-up views appear blurry due to the fixed focus point of the low-cost camera. The presented steering concept of the camera is promising, as it could potentially improve imaging of narrow cavities using flexible endoscopes. Especially for “in office” examinations this principle could add value to diagnosis and patient comfort.
format article
author Boese Axel
Arens Christoph
Friebe Michael
author_facet Boese Axel
Arens Christoph
Friebe Michael
author_sort Boese Axel
title Novel flexible endoscope concept with swiveling camera tip
title_short Novel flexible endoscope concept with swiveling camera tip
title_full Novel flexible endoscope concept with swiveling camera tip
title_fullStr Novel flexible endoscope concept with swiveling camera tip
title_full_unstemmed Novel flexible endoscope concept with swiveling camera tip
title_sort novel flexible endoscope concept with swiveling camera tip
publisher De Gruyter
publishDate 2020
url https://doaj.org/article/3257ac904b404b6db51af41813cf98e6
work_keys_str_mv AT boeseaxel novelflexibleendoscopeconceptwithswivelingcameratip
AT arenschristoph novelflexibleendoscopeconceptwithswivelingcameratip
AT friebemichael novelflexibleendoscopeconceptwithswivelingcameratip
_version_ 1718371832507138048