PLGA Coatings and PLGA Drug-Loading Coatings for Cardiac Stent Samples: Degradation Characteristics and Blood Compatibility
PLGA (Poly lactic-co-glycolic acid) and PLGA drug-loading coatings were prepared on 316 L stainless steel by electrostatic spray deposition (ESD). The surface morphology, three-dimensional morphology, and crystal structures of the coatings were observed by scanning electron microscopy (SEM), atomic...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/328ce5e68ef24f3ea03f5f9592e037d3 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:328ce5e68ef24f3ea03f5f9592e037d3 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:328ce5e68ef24f3ea03f5f9592e037d32021-11-25T17:17:07ZPLGA Coatings and PLGA Drug-Loading Coatings for Cardiac Stent Samples: Degradation Characteristics and Blood Compatibility10.3390/coatings111114272079-6412https://doaj.org/article/328ce5e68ef24f3ea03f5f9592e037d32021-11-01T00:00:00Zhttps://www.mdpi.com/2079-6412/11/11/1427https://doaj.org/toc/2079-6412PLGA (Poly lactic-co-glycolic acid) and PLGA drug-loading coatings were prepared on 316 L stainless steel by electrostatic spray deposition (ESD). The surface morphology, three-dimensional morphology, and crystal structures of the coatings were observed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray diffraction (XRD). Thermal properties, molecular weight, and coating composition were studied by differential scanning calorimetry (DSC), gel permeation chromatography (GPC), and NMR. The degradation behaviors of the coatings were studied by mass changes, relative molecular mass and distributions, polymer compositions, thermal properties, and surface morphologies. The blood compatibilities of the coatings were investigated by platelet adhesion testing and dynamic coagulation times. SEM results indicated the drug-loading coating with 33% RAPA had the smoothest and most compact morphology. Addition of RAPA decreased the Tg of the PLGA coating, accompanied by partial crystallization that slowed the degradation rate of the drug-loaded coating. Microscopically, the morphology of the PLGA drug-loaded coating was coarser than the PLGA coating. The average surface roughness values of line and surface scannings were 16.232 nm and 39.538 nm, respectively. The surface of the drug-loading coating was micro uneven, and the macro smooth and micro multiphase separation structure helped improve its blood compatibility.Ziyang JiaChunyang MaHongbin ZhangMDPI AGarticledrug-loading coatingspreparationcharacterizationblood compatibilityEngineering (General). Civil engineering (General)TA1-2040ENCoatings, Vol 11, Iss 1427, p 1427 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
drug-loading coatings preparation characterization blood compatibility Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
drug-loading coatings preparation characterization blood compatibility Engineering (General). Civil engineering (General) TA1-2040 Ziyang Jia Chunyang Ma Hongbin Zhang PLGA Coatings and PLGA Drug-Loading Coatings for Cardiac Stent Samples: Degradation Characteristics and Blood Compatibility |
description |
PLGA (Poly lactic-co-glycolic acid) and PLGA drug-loading coatings were prepared on 316 L stainless steel by electrostatic spray deposition (ESD). The surface morphology, three-dimensional morphology, and crystal structures of the coatings were observed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray diffraction (XRD). Thermal properties, molecular weight, and coating composition were studied by differential scanning calorimetry (DSC), gel permeation chromatography (GPC), and NMR. The degradation behaviors of the coatings were studied by mass changes, relative molecular mass and distributions, polymer compositions, thermal properties, and surface morphologies. The blood compatibilities of the coatings were investigated by platelet adhesion testing and dynamic coagulation times. SEM results indicated the drug-loading coating with 33% RAPA had the smoothest and most compact morphology. Addition of RAPA decreased the Tg of the PLGA coating, accompanied by partial crystallization that slowed the degradation rate of the drug-loaded coating. Microscopically, the morphology of the PLGA drug-loaded coating was coarser than the PLGA coating. The average surface roughness values of line and surface scannings were 16.232 nm and 39.538 nm, respectively. The surface of the drug-loading coating was micro uneven, and the macro smooth and micro multiphase separation structure helped improve its blood compatibility. |
format |
article |
author |
Ziyang Jia Chunyang Ma Hongbin Zhang |
author_facet |
Ziyang Jia Chunyang Ma Hongbin Zhang |
author_sort |
Ziyang Jia |
title |
PLGA Coatings and PLGA Drug-Loading Coatings for Cardiac Stent Samples: Degradation Characteristics and Blood Compatibility |
title_short |
PLGA Coatings and PLGA Drug-Loading Coatings for Cardiac Stent Samples: Degradation Characteristics and Blood Compatibility |
title_full |
PLGA Coatings and PLGA Drug-Loading Coatings for Cardiac Stent Samples: Degradation Characteristics and Blood Compatibility |
title_fullStr |
PLGA Coatings and PLGA Drug-Loading Coatings for Cardiac Stent Samples: Degradation Characteristics and Blood Compatibility |
title_full_unstemmed |
PLGA Coatings and PLGA Drug-Loading Coatings for Cardiac Stent Samples: Degradation Characteristics and Blood Compatibility |
title_sort |
plga coatings and plga drug-loading coatings for cardiac stent samples: degradation characteristics and blood compatibility |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/328ce5e68ef24f3ea03f5f9592e037d3 |
work_keys_str_mv |
AT ziyangjia plgacoatingsandplgadrugloadingcoatingsforcardiacstentsamplesdegradationcharacteristicsandbloodcompatibility AT chunyangma plgacoatingsandplgadrugloadingcoatingsforcardiacstentsamplesdegradationcharacteristicsandbloodcompatibility AT hongbinzhang plgacoatingsandplgadrugloadingcoatingsforcardiacstentsamplesdegradationcharacteristicsandbloodcompatibility |
_version_ |
1718412522221993984 |