Observations on the Changing Shape of the Ice Mass and the Determination of the Sublimation End Point in Freeze-Drying: An Application for Through-Vial Impedance Spectroscopy (TVIS)

Models for ice sublimation from a freeze-drying vial rely on the assumption of a planar ice interface up to ~25% loss of ice mass (which is difficult to qualify) whereas single-vial determinations of the sublimation endpoint (by temperature sensors) are based on the point when the observed temperatu...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bhaskar Pandya, Geoff Smith, Irina Ermolina, Evgeny Polygalov
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/334a9891507a4d87abd29836de8879d7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:334a9891507a4d87abd29836de8879d7
record_format dspace
spelling oai:doaj.org-article:334a9891507a4d87abd29836de8879d72021-11-25T18:41:05ZObservations on the Changing Shape of the Ice Mass and the Determination of the Sublimation End Point in Freeze-Drying: An Application for Through-Vial Impedance Spectroscopy (TVIS)10.3390/pharmaceutics131118351999-4923https://doaj.org/article/334a9891507a4d87abd29836de8879d72021-11-01T00:00:00Zhttps://www.mdpi.com/1999-4923/13/11/1835https://doaj.org/toc/1999-4923Models for ice sublimation from a freeze-drying vial rely on the assumption of a planar ice interface up to ~25% loss of ice mass (which is difficult to qualify) whereas single-vial determinations of the sublimation endpoint (by temperature sensors) are based on the point when the observed temperature reaches a plateau, which cannot differentiate between sublimation and desorption-drying. In this work, the real part capacitance of TVIS vial(s) containing frozen water (during sublimation drying) was measured at 100 kHz. This parameter <inline-formula><math display="inline"><semantics><mrow><msup><mi>C</mi><mo>′</mo></msup><mrow><mo>(</mo><mrow><mn>100</mn><mrow><mtext> </mtext><mi>kHz</mi></mrow></mrow><mo>)</mo></mrow></mrow></semantics></math></inline-formula> was shown to be highly sensitive to the shape and volume of the ice mass and is therefore a useful parameter for monitoring ice sublimation. By placing a digital camera in front of an isolated TVIS vial containing ice, it was possible to relate the changes in the shape of the ice mass with the changes in the trajectory of the time profile of <inline-formula><math display="inline"><semantics><mrow><msup><mi>C</mi><mo>′</mo></msup><mrow><mo>(</mo><mrow><mn>100</mn><mrow><mtext> </mtext><mi>kHz</mi></mrow></mrow><mo>)</mo></mrow></mrow></semantics></math></inline-formula> and determine the point of deviation from a planar ice interface and ultimately determine the point when the last vestiges of ice disappear. Thereafter, the same characteristics of the <inline-formula><math display="inline"><semantics><mrow><msup><mi>C</mi><mo>′</mo></msup><mrow><mo>(</mo><mrow><mn>100</mn><mrow><mtext> </mtext><mi>kHz</mi></mrow></mrow><mo>)</mo></mrow></mrow></semantics></math></inline-formula> time-profile were identified for those TVIS vials located out of sight of the camera in a separate full-shelf lyo study, thereby obviating the need for photographic examination.Bhaskar PandyaGeoff SmithIrina ErmolinaEvgeny PolygalovMDPI AGarticlefreeze-dryingprimary drying endpointthermocouplesingle-vialprocess analytical technologyPharmacy and materia medicaRS1-441ENPharmaceutics, Vol 13, Iss 1835, p 1835 (2021)
institution DOAJ
collection DOAJ
language EN
topic freeze-drying
primary drying endpoint
thermocouple
single-vial
process analytical technology
Pharmacy and materia medica
RS1-441
spellingShingle freeze-drying
primary drying endpoint
thermocouple
single-vial
process analytical technology
Pharmacy and materia medica
RS1-441
Bhaskar Pandya
Geoff Smith
Irina Ermolina
Evgeny Polygalov
Observations on the Changing Shape of the Ice Mass and the Determination of the Sublimation End Point in Freeze-Drying: An Application for Through-Vial Impedance Spectroscopy (TVIS)
description Models for ice sublimation from a freeze-drying vial rely on the assumption of a planar ice interface up to ~25% loss of ice mass (which is difficult to qualify) whereas single-vial determinations of the sublimation endpoint (by temperature sensors) are based on the point when the observed temperature reaches a plateau, which cannot differentiate between sublimation and desorption-drying. In this work, the real part capacitance of TVIS vial(s) containing frozen water (during sublimation drying) was measured at 100 kHz. This parameter <inline-formula><math display="inline"><semantics><mrow><msup><mi>C</mi><mo>′</mo></msup><mrow><mo>(</mo><mrow><mn>100</mn><mrow><mtext> </mtext><mi>kHz</mi></mrow></mrow><mo>)</mo></mrow></mrow></semantics></math></inline-formula> was shown to be highly sensitive to the shape and volume of the ice mass and is therefore a useful parameter for monitoring ice sublimation. By placing a digital camera in front of an isolated TVIS vial containing ice, it was possible to relate the changes in the shape of the ice mass with the changes in the trajectory of the time profile of <inline-formula><math display="inline"><semantics><mrow><msup><mi>C</mi><mo>′</mo></msup><mrow><mo>(</mo><mrow><mn>100</mn><mrow><mtext> </mtext><mi>kHz</mi></mrow></mrow><mo>)</mo></mrow></mrow></semantics></math></inline-formula> and determine the point of deviation from a planar ice interface and ultimately determine the point when the last vestiges of ice disappear. Thereafter, the same characteristics of the <inline-formula><math display="inline"><semantics><mrow><msup><mi>C</mi><mo>′</mo></msup><mrow><mo>(</mo><mrow><mn>100</mn><mrow><mtext> </mtext><mi>kHz</mi></mrow></mrow><mo>)</mo></mrow></mrow></semantics></math></inline-formula> time-profile were identified for those TVIS vials located out of sight of the camera in a separate full-shelf lyo study, thereby obviating the need for photographic examination.
format article
author Bhaskar Pandya
Geoff Smith
Irina Ermolina
Evgeny Polygalov
author_facet Bhaskar Pandya
Geoff Smith
Irina Ermolina
Evgeny Polygalov
author_sort Bhaskar Pandya
title Observations on the Changing Shape of the Ice Mass and the Determination of the Sublimation End Point in Freeze-Drying: An Application for Through-Vial Impedance Spectroscopy (TVIS)
title_short Observations on the Changing Shape of the Ice Mass and the Determination of the Sublimation End Point in Freeze-Drying: An Application for Through-Vial Impedance Spectroscopy (TVIS)
title_full Observations on the Changing Shape of the Ice Mass and the Determination of the Sublimation End Point in Freeze-Drying: An Application for Through-Vial Impedance Spectroscopy (TVIS)
title_fullStr Observations on the Changing Shape of the Ice Mass and the Determination of the Sublimation End Point in Freeze-Drying: An Application for Through-Vial Impedance Spectroscopy (TVIS)
title_full_unstemmed Observations on the Changing Shape of the Ice Mass and the Determination of the Sublimation End Point in Freeze-Drying: An Application for Through-Vial Impedance Spectroscopy (TVIS)
title_sort observations on the changing shape of the ice mass and the determination of the sublimation end point in freeze-drying: an application for through-vial impedance spectroscopy (tvis)
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/334a9891507a4d87abd29836de8879d7
work_keys_str_mv AT bhaskarpandya observationsonthechangingshapeoftheicemassandthedeterminationofthesublimationendpointinfreezedryinganapplicationforthroughvialimpedancespectroscopytvis
AT geoffsmith observationsonthechangingshapeoftheicemassandthedeterminationofthesublimationendpointinfreezedryinganapplicationforthroughvialimpedancespectroscopytvis
AT irinaermolina observationsonthechangingshapeoftheicemassandthedeterminationofthesublimationendpointinfreezedryinganapplicationforthroughvialimpedancespectroscopytvis
AT evgenypolygalov observationsonthechangingshapeoftheicemassandthedeterminationofthesublimationendpointinfreezedryinganapplicationforthroughvialimpedancespectroscopytvis
_version_ 1718410825723543552