Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings

It’s for more than three decades that Steel Shear Walls are being used as lateral load resisting system. Definitely,the actual behavior of steel shear walls can be assessed using experimental results. However, solve many of phenomenon like this one should be done using mathematical and theoretical m...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mojtaba Ghasemzadeh, Mansour Ghalehnovi, Abdolhamid Bahrpeyma
Formato: article
Lenguaje:FA
Publicado: Iranian Society of Structrual Engineering (ISSE) 2015
Materias:
Acceso en línea:https://doaj.org/article/33872d22bbd442ccb78f6b4f7f5fef1f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:33872d22bbd442ccb78f6b4f7f5fef1f
record_format dspace
spelling oai:doaj.org-article:33872d22bbd442ccb78f6b4f7f5fef1f2021-11-08T15:44:59ZEffect of FRP on the Energy Absorbed by Steel Shear Walls with Openings2476-39772538-2616https://doaj.org/article/33872d22bbd442ccb78f6b4f7f5fef1f2015-06-01T00:00:00Zhttps://www.jsce.ir/article_38615_0847a8cb34dde42b60e0b91b05e282b8.pdfhttps://doaj.org/toc/2476-3977https://doaj.org/toc/2538-2616It’s for more than three decades that Steel Shear Walls are being used as lateral load resisting system. Definitely,the actual behavior of steel shear walls can be assessed using experimental results. However, solve many of phenomenon like this one should be done using mathematical and theoretical methods due to their special characteristics such as high expenses, lack of laboratory facilities and time limitations. In this study, the behavior of steel plate shear walls with openings in a one-story frame were evaluated and compared in various conditions. For this purpose, different values ​​for the opening in shear wall was considered and exposed to lateral displacement in ABAQUS as a comprehensive finite element software. Then, the impact of FRP arrangement on shear wall was evaluated to represent the structural behavior under various conditions. Result shows that, use of FRP sheets as parallel layers on both sides of shear wall has the best response on energy absorption, so that performance of the model was better than shear wall fully covered with FRP.Mojtaba GhasemzadehMansour GhalehnoviAbdolhamid BahrpeymaIranian Society of Structrual Engineering (ISSE)articlesteel plate shear wallfrp reinforceopening in shear wallenergy absorptionBridge engineeringTG1-470Building constructionTH1-9745FAJournal of Structural and Construction Engineering, Vol 2, Iss 1, Pp 34-45 (2015)
institution DOAJ
collection DOAJ
language FA
topic steel plate shear wall
frp reinforce
opening in shear wall
energy absorption
Bridge engineering
TG1-470
Building construction
TH1-9745
spellingShingle steel plate shear wall
frp reinforce
opening in shear wall
energy absorption
Bridge engineering
TG1-470
Building construction
TH1-9745
Mojtaba Ghasemzadeh
Mansour Ghalehnovi
Abdolhamid Bahrpeyma
Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings
description It’s for more than three decades that Steel Shear Walls are being used as lateral load resisting system. Definitely,the actual behavior of steel shear walls can be assessed using experimental results. However, solve many of phenomenon like this one should be done using mathematical and theoretical methods due to their special characteristics such as high expenses, lack of laboratory facilities and time limitations. In this study, the behavior of steel plate shear walls with openings in a one-story frame were evaluated and compared in various conditions. For this purpose, different values ​​for the opening in shear wall was considered and exposed to lateral displacement in ABAQUS as a comprehensive finite element software. Then, the impact of FRP arrangement on shear wall was evaluated to represent the structural behavior under various conditions. Result shows that, use of FRP sheets as parallel layers on both sides of shear wall has the best response on energy absorption, so that performance of the model was better than shear wall fully covered with FRP.
format article
author Mojtaba Ghasemzadeh
Mansour Ghalehnovi
Abdolhamid Bahrpeyma
author_facet Mojtaba Ghasemzadeh
Mansour Ghalehnovi
Abdolhamid Bahrpeyma
author_sort Mojtaba Ghasemzadeh
title Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings
title_short Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings
title_full Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings
title_fullStr Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings
title_full_unstemmed Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings
title_sort effect of frp on the energy absorbed by steel shear walls with openings
publisher Iranian Society of Structrual Engineering (ISSE)
publishDate 2015
url https://doaj.org/article/33872d22bbd442ccb78f6b4f7f5fef1f
work_keys_str_mv AT mojtabaghasemzadeh effectoffrpontheenergyabsorbedbysteelshearwallswithopenings
AT mansourghalehnovi effectoffrpontheenergyabsorbedbysteelshearwallswithopenings
AT abdolhamidbahrpeyma effectoffrpontheenergyabsorbedbysteelshearwallswithopenings
_version_ 1718441736983805952