Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings
It’s for more than three decades that Steel Shear Walls are being used as lateral load resisting system. Definitely,the actual behavior of steel shear walls can be assessed using experimental results. However, solve many of phenomenon like this one should be done using mathematical and theoretical m...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | FA |
Publicado: |
Iranian Society of Structrual Engineering (ISSE)
2015
|
Materias: | |
Acceso en línea: | https://doaj.org/article/33872d22bbd442ccb78f6b4f7f5fef1f |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:33872d22bbd442ccb78f6b4f7f5fef1f |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:33872d22bbd442ccb78f6b4f7f5fef1f2021-11-08T15:44:59ZEffect of FRP on the Energy Absorbed by Steel Shear Walls with Openings2476-39772538-2616https://doaj.org/article/33872d22bbd442ccb78f6b4f7f5fef1f2015-06-01T00:00:00Zhttps://www.jsce.ir/article_38615_0847a8cb34dde42b60e0b91b05e282b8.pdfhttps://doaj.org/toc/2476-3977https://doaj.org/toc/2538-2616It’s for more than three decades that Steel Shear Walls are being used as lateral load resisting system. Definitely,the actual behavior of steel shear walls can be assessed using experimental results. However, solve many of phenomenon like this one should be done using mathematical and theoretical methods due to their special characteristics such as high expenses, lack of laboratory facilities and time limitations. In this study, the behavior of steel plate shear walls with openings in a one-story frame were evaluated and compared in various conditions. For this purpose, different values for the opening in shear wall was considered and exposed to lateral displacement in ABAQUS as a comprehensive finite element software. Then, the impact of FRP arrangement on shear wall was evaluated to represent the structural behavior under various conditions. Result shows that, use of FRP sheets as parallel layers on both sides of shear wall has the best response on energy absorption, so that performance of the model was better than shear wall fully covered with FRP.Mojtaba GhasemzadehMansour GhalehnoviAbdolhamid BahrpeymaIranian Society of Structrual Engineering (ISSE)articlesteel plate shear wallfrp reinforceopening in shear wallenergy absorptionBridge engineeringTG1-470Building constructionTH1-9745FAJournal of Structural and Construction Engineering, Vol 2, Iss 1, Pp 34-45 (2015) |
institution |
DOAJ |
collection |
DOAJ |
language |
FA |
topic |
steel plate shear wall frp reinforce opening in shear wall energy absorption Bridge engineering TG1-470 Building construction TH1-9745 |
spellingShingle |
steel plate shear wall frp reinforce opening in shear wall energy absorption Bridge engineering TG1-470 Building construction TH1-9745 Mojtaba Ghasemzadeh Mansour Ghalehnovi Abdolhamid Bahrpeyma Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
description |
It’s for more than three decades that Steel Shear Walls are being used as lateral load resisting system. Definitely,the actual behavior of steel shear walls can be assessed using experimental results. However, solve many of phenomenon like this one should be done using mathematical and theoretical methods due to their special characteristics such as high expenses, lack of laboratory facilities and time limitations. In this study, the behavior of steel plate shear walls with openings in a one-story frame were evaluated and compared in various conditions. For this purpose, different values for the opening in shear wall was considered and exposed to lateral displacement in ABAQUS as a comprehensive finite element software. Then, the impact of FRP arrangement on shear wall was evaluated to represent the structural behavior under various conditions. Result shows that, use of FRP sheets as parallel layers on both sides of shear wall has the best response on energy absorption, so that performance of the model was better than shear wall fully covered with FRP. |
format |
article |
author |
Mojtaba Ghasemzadeh Mansour Ghalehnovi Abdolhamid Bahrpeyma |
author_facet |
Mojtaba Ghasemzadeh Mansour Ghalehnovi Abdolhamid Bahrpeyma |
author_sort |
Mojtaba Ghasemzadeh |
title |
Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_short |
Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_full |
Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_fullStr |
Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_full_unstemmed |
Effect of FRP on the Energy Absorbed by Steel Shear Walls with Openings |
title_sort |
effect of frp on the energy absorbed by steel shear walls with openings |
publisher |
Iranian Society of Structrual Engineering (ISSE) |
publishDate |
2015 |
url |
https://doaj.org/article/33872d22bbd442ccb78f6b4f7f5fef1f |
work_keys_str_mv |
AT mojtabaghasemzadeh effectoffrpontheenergyabsorbedbysteelshearwallswithopenings AT mansourghalehnovi effectoffrpontheenergyabsorbedbysteelshearwallswithopenings AT abdolhamidbahrpeyma effectoffrpontheenergyabsorbedbysteelshearwallswithopenings |
_version_ |
1718441736983805952 |