VALIDITY AND RELIABILITY OF INSTRUMENT TO MEASURE CLINICAL INDICATOR OF NURSING DIAGNOSIS: FATIGUE ON PATIENT UNDERTAKING HAEMODIALYSIS

Background: Fatigue as nursing diagnosis is a common phenomenon in patient undertaking hemodialysis. There is, however, no clear instrument to measure the clinical indicators of this nursing diagnosis. Objectives: To measure the validity and reliability an instrument to measure clinical indicator...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Atika Dwi Astuti, Intansari Nurjannah, Sri Mulyani
Formato: article
Lenguaje:EN
Publicado: Belitung Raya Foundation 2018
Materias:
Acceso en línea:https://doaj.org/article/357babd5a6044606800c2eb88a624be3
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:357babd5a6044606800c2eb88a624be3
record_format dspace
spelling oai:doaj.org-article:357babd5a6044606800c2eb88a624be32021-12-02T11:27:30ZVALIDITY AND RELIABILITY OF INSTRUMENT TO MEASURE CLINICAL INDICATOR OF NURSING DIAGNOSIS: FATIGUE ON PATIENT UNDERTAKING HAEMODIALYSIS2477-40732477-4073https://doaj.org/article/357babd5a6044606800c2eb88a624be32018-06-01T00:00:00Zhttp://belitungraya.org/BRP/index.php/bnj/article/view/424https://doaj.org/toc/2477-4073https://doaj.org/toc/2477-4073Background: Fatigue as nursing diagnosis is a common phenomenon in patient undertaking hemodialysis. There is, however, no clear instrument to measure the clinical indicators of this nursing diagnosis. Objectives: To measure the validity and reliability an instrument to measure clinical indicator in nursing diagnosis fatigue. Methods: Content Validity Index for Scale (S-CVI) and Point-Biserial Correlation were used to measure the validity of instrument. Cronbach Alpha Reliability was used for reliability of 72 patients undertaking haemodialysis. Results: S-CVI score was 1 on relevance, accuracy and clarity, 0.98 on simplicity and ambiguity. The Cronbach’s Alpha of the instrument was 0.675 which was considered reliable. Conclusion: The instrument to measure clinical indicators of nursing diagnoses fatigue has acceptable validity and reliability score in Indonesian, and it is recommended to be used in clinical setting. Atika Dwi AstutiIntansari NurjannahSri MulyaniBelitung Raya FoundationarticleValidityreliabilityfatiguehaemodialysisNursingRT1-120ENBelitung Nursing Journal, Vol 4, Iss 3, Pp 350-355 (2018)
institution DOAJ
collection DOAJ
language EN
topic Validity
reliability
fatigue
haemodialysis
Nursing
RT1-120
spellingShingle Validity
reliability
fatigue
haemodialysis
Nursing
RT1-120
Atika Dwi Astuti
Intansari Nurjannah
Sri Mulyani
VALIDITY AND RELIABILITY OF INSTRUMENT TO MEASURE CLINICAL INDICATOR OF NURSING DIAGNOSIS: FATIGUE ON PATIENT UNDERTAKING HAEMODIALYSIS
description Background: Fatigue as nursing diagnosis is a common phenomenon in patient undertaking hemodialysis. There is, however, no clear instrument to measure the clinical indicators of this nursing diagnosis. Objectives: To measure the validity and reliability an instrument to measure clinical indicator in nursing diagnosis fatigue. Methods: Content Validity Index for Scale (S-CVI) and Point-Biserial Correlation were used to measure the validity of instrument. Cronbach Alpha Reliability was used for reliability of 72 patients undertaking haemodialysis. Results: S-CVI score was 1 on relevance, accuracy and clarity, 0.98 on simplicity and ambiguity. The Cronbach’s Alpha of the instrument was 0.675 which was considered reliable. Conclusion: The instrument to measure clinical indicators of nursing diagnoses fatigue has acceptable validity and reliability score in Indonesian, and it is recommended to be used in clinical setting.
format article
author Atika Dwi Astuti
Intansari Nurjannah
Sri Mulyani
author_facet Atika Dwi Astuti
Intansari Nurjannah
Sri Mulyani
author_sort Atika Dwi Astuti
title VALIDITY AND RELIABILITY OF INSTRUMENT TO MEASURE CLINICAL INDICATOR OF NURSING DIAGNOSIS: FATIGUE ON PATIENT UNDERTAKING HAEMODIALYSIS
title_short VALIDITY AND RELIABILITY OF INSTRUMENT TO MEASURE CLINICAL INDICATOR OF NURSING DIAGNOSIS: FATIGUE ON PATIENT UNDERTAKING HAEMODIALYSIS
title_full VALIDITY AND RELIABILITY OF INSTRUMENT TO MEASURE CLINICAL INDICATOR OF NURSING DIAGNOSIS: FATIGUE ON PATIENT UNDERTAKING HAEMODIALYSIS
title_fullStr VALIDITY AND RELIABILITY OF INSTRUMENT TO MEASURE CLINICAL INDICATOR OF NURSING DIAGNOSIS: FATIGUE ON PATIENT UNDERTAKING HAEMODIALYSIS
title_full_unstemmed VALIDITY AND RELIABILITY OF INSTRUMENT TO MEASURE CLINICAL INDICATOR OF NURSING DIAGNOSIS: FATIGUE ON PATIENT UNDERTAKING HAEMODIALYSIS
title_sort validity and reliability of instrument to measure clinical indicator of nursing diagnosis: fatigue on patient undertaking haemodialysis
publisher Belitung Raya Foundation
publishDate 2018
url https://doaj.org/article/357babd5a6044606800c2eb88a624be3
work_keys_str_mv AT atikadwiastuti validityandreliabilityofinstrumenttomeasureclinicalindicatorofnursingdiagnosisfatigueonpatientundertakinghaemodialysis
AT intansarinurjannah validityandreliabilityofinstrumenttomeasureclinicalindicatorofnursingdiagnosisfatigueonpatientundertakinghaemodialysis
AT srimulyani validityandreliabilityofinstrumenttomeasureclinicalindicatorofnursingdiagnosisfatigueonpatientundertakinghaemodialysis
_version_ 1718395931514109952