Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates

Children inhale indoor air at 400 mL/min∙kg per body weight, 2.76 times more than adults. They have weaker immunity than adults and are more exposed to asthma, allergies, and atopic diseases. The objective of this paper is to suggest effective management and improvement measures for indoor air quali...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mohammad Arar, Chuloh Jung
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
R
Acceso en línea:https://doaj.org/article/35c46f71e03747deb4be842186c7e82c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:35c46f71e03747deb4be842186c7e82c
record_format dspace
spelling oai:doaj.org-article:35c46f71e03747deb4be842186c7e82c2021-11-25T17:51:02ZImproving the Indoor Air Quality in Nursery Buildings in United Arab Emirates10.3390/ijerph1822120911660-46011661-7827https://doaj.org/article/35c46f71e03747deb4be842186c7e82c2021-11-01T00:00:00Zhttps://www.mdpi.com/1660-4601/18/22/12091https://doaj.org/toc/1661-7827https://doaj.org/toc/1660-4601Children inhale indoor air at 400 mL/min∙kg per body weight, 2.76 times more than adults. They have weaker immunity than adults and are more exposed to asthma, allergies, and atopic diseases. The objective of this paper is to suggest effective management and improvement measures for indoor air quality for nurseries. As a methodology, 16 nurseries (total of 35 classrooms) were selected to measure the indoor air quality compared with WHO IAQ Standard, and identify the daily concentration change of the pollutants. Based on the measurements, IAQ improvements for selected facilities are carried out to compare the results before and after improvement. The result has shown that the concentration of Carbon Dioxide (CO<sub>2</sub>), Total Volatile Organic Compounds (TVOC), Total Suspended Particles (TSP) and formaldehyde (CH<sub>2</sub>O) exceeds WHO IAQ standards. The concentration of CO<sub>2</sub> and TSP is changed mainly by physical activity of children and that of CH<sub>2</sub>O and TVOC is changed mainly by ventilation after school start. TVOC decreased by 46.4% and the TSP decreased by 21.7% after air purifier, but CH<sub>2</sub>O and TVOC increased 1.8–3.8 times after interior renovation with low-emission finishing materials. After new ventilation installation, the CH<sub>2</sub>O and TVOC reduced half and the TSP reduced one third. It is proven that the most effective way to reduce the concentration of air pollutants in nurseries is the installation of a new ventilation system, followed by an air purifier. The renovation with low-emission finishing materials cannot improve IAQ in a short period of time.Mohammad ArarChuloh JungMDPI AGarticleIndoor Air Quality (IAQ)nurseryair purifierfinishing material changeUnited Arab EmiratesMedicineRENInternational Journal of Environmental Research and Public Health, Vol 18, Iss 12091, p 12091 (2021)
institution DOAJ
collection DOAJ
language EN
topic Indoor Air Quality (IAQ)
nursery
air purifier
finishing material change
United Arab Emirates
Medicine
R
spellingShingle Indoor Air Quality (IAQ)
nursery
air purifier
finishing material change
United Arab Emirates
Medicine
R
Mohammad Arar
Chuloh Jung
Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates
description Children inhale indoor air at 400 mL/min∙kg per body weight, 2.76 times more than adults. They have weaker immunity than adults and are more exposed to asthma, allergies, and atopic diseases. The objective of this paper is to suggest effective management and improvement measures for indoor air quality for nurseries. As a methodology, 16 nurseries (total of 35 classrooms) were selected to measure the indoor air quality compared with WHO IAQ Standard, and identify the daily concentration change of the pollutants. Based on the measurements, IAQ improvements for selected facilities are carried out to compare the results before and after improvement. The result has shown that the concentration of Carbon Dioxide (CO<sub>2</sub>), Total Volatile Organic Compounds (TVOC), Total Suspended Particles (TSP) and formaldehyde (CH<sub>2</sub>O) exceeds WHO IAQ standards. The concentration of CO<sub>2</sub> and TSP is changed mainly by physical activity of children and that of CH<sub>2</sub>O and TVOC is changed mainly by ventilation after school start. TVOC decreased by 46.4% and the TSP decreased by 21.7% after air purifier, but CH<sub>2</sub>O and TVOC increased 1.8–3.8 times after interior renovation with low-emission finishing materials. After new ventilation installation, the CH<sub>2</sub>O and TVOC reduced half and the TSP reduced one third. It is proven that the most effective way to reduce the concentration of air pollutants in nurseries is the installation of a new ventilation system, followed by an air purifier. The renovation with low-emission finishing materials cannot improve IAQ in a short period of time.
format article
author Mohammad Arar
Chuloh Jung
author_facet Mohammad Arar
Chuloh Jung
author_sort Mohammad Arar
title Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates
title_short Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates
title_full Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates
title_fullStr Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates
title_full_unstemmed Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates
title_sort improving the indoor air quality in nursery buildings in united arab emirates
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/35c46f71e03747deb4be842186c7e82c
work_keys_str_mv AT mohammadarar improvingtheindoorairqualityinnurserybuildingsinunitedarabemirates
AT chulohjung improvingtheindoorairqualityinnurserybuildingsinunitedarabemirates
_version_ 1718411914444275712