Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates
Children inhale indoor air at 400 mL/min∙kg per body weight, 2.76 times more than adults. They have weaker immunity than adults and are more exposed to asthma, allergies, and atopic diseases. The objective of this paper is to suggest effective management and improvement measures for indoor air quali...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/35c46f71e03747deb4be842186c7e82c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:35c46f71e03747deb4be842186c7e82c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:35c46f71e03747deb4be842186c7e82c2021-11-25T17:51:02ZImproving the Indoor Air Quality in Nursery Buildings in United Arab Emirates10.3390/ijerph1822120911660-46011661-7827https://doaj.org/article/35c46f71e03747deb4be842186c7e82c2021-11-01T00:00:00Zhttps://www.mdpi.com/1660-4601/18/22/12091https://doaj.org/toc/1661-7827https://doaj.org/toc/1660-4601Children inhale indoor air at 400 mL/min∙kg per body weight, 2.76 times more than adults. They have weaker immunity than adults and are more exposed to asthma, allergies, and atopic diseases. The objective of this paper is to suggest effective management and improvement measures for indoor air quality for nurseries. As a methodology, 16 nurseries (total of 35 classrooms) were selected to measure the indoor air quality compared with WHO IAQ Standard, and identify the daily concentration change of the pollutants. Based on the measurements, IAQ improvements for selected facilities are carried out to compare the results before and after improvement. The result has shown that the concentration of Carbon Dioxide (CO<sub>2</sub>), Total Volatile Organic Compounds (TVOC), Total Suspended Particles (TSP) and formaldehyde (CH<sub>2</sub>O) exceeds WHO IAQ standards. The concentration of CO<sub>2</sub> and TSP is changed mainly by physical activity of children and that of CH<sub>2</sub>O and TVOC is changed mainly by ventilation after school start. TVOC decreased by 46.4% and the TSP decreased by 21.7% after air purifier, but CH<sub>2</sub>O and TVOC increased 1.8–3.8 times after interior renovation with low-emission finishing materials. After new ventilation installation, the CH<sub>2</sub>O and TVOC reduced half and the TSP reduced one third. It is proven that the most effective way to reduce the concentration of air pollutants in nurseries is the installation of a new ventilation system, followed by an air purifier. The renovation with low-emission finishing materials cannot improve IAQ in a short period of time.Mohammad ArarChuloh JungMDPI AGarticleIndoor Air Quality (IAQ)nurseryair purifierfinishing material changeUnited Arab EmiratesMedicineRENInternational Journal of Environmental Research and Public Health, Vol 18, Iss 12091, p 12091 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Indoor Air Quality (IAQ) nursery air purifier finishing material change United Arab Emirates Medicine R |
spellingShingle |
Indoor Air Quality (IAQ) nursery air purifier finishing material change United Arab Emirates Medicine R Mohammad Arar Chuloh Jung Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates |
description |
Children inhale indoor air at 400 mL/min∙kg per body weight, 2.76 times more than adults. They have weaker immunity than adults and are more exposed to asthma, allergies, and atopic diseases. The objective of this paper is to suggest effective management and improvement measures for indoor air quality for nurseries. As a methodology, 16 nurseries (total of 35 classrooms) were selected to measure the indoor air quality compared with WHO IAQ Standard, and identify the daily concentration change of the pollutants. Based on the measurements, IAQ improvements for selected facilities are carried out to compare the results before and after improvement. The result has shown that the concentration of Carbon Dioxide (CO<sub>2</sub>), Total Volatile Organic Compounds (TVOC), Total Suspended Particles (TSP) and formaldehyde (CH<sub>2</sub>O) exceeds WHO IAQ standards. The concentration of CO<sub>2</sub> and TSP is changed mainly by physical activity of children and that of CH<sub>2</sub>O and TVOC is changed mainly by ventilation after school start. TVOC decreased by 46.4% and the TSP decreased by 21.7% after air purifier, but CH<sub>2</sub>O and TVOC increased 1.8–3.8 times after interior renovation with low-emission finishing materials. After new ventilation installation, the CH<sub>2</sub>O and TVOC reduced half and the TSP reduced one third. It is proven that the most effective way to reduce the concentration of air pollutants in nurseries is the installation of a new ventilation system, followed by an air purifier. The renovation with low-emission finishing materials cannot improve IAQ in a short period of time. |
format |
article |
author |
Mohammad Arar Chuloh Jung |
author_facet |
Mohammad Arar Chuloh Jung |
author_sort |
Mohammad Arar |
title |
Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates |
title_short |
Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates |
title_full |
Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates |
title_fullStr |
Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates |
title_full_unstemmed |
Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates |
title_sort |
improving the indoor air quality in nursery buildings in united arab emirates |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/35c46f71e03747deb4be842186c7e82c |
work_keys_str_mv |
AT mohammadarar improvingtheindoorairqualityinnurserybuildingsinunitedarabemirates AT chulohjung improvingtheindoorairqualityinnurserybuildingsinunitedarabemirates |
_version_ |
1718411914444275712 |