Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system

Abstract This work presents the first tests performed with radiochromic films and a new Micro‒Opto‒Electro-Mechanical system (MOEMS) for in situ dosimetry evaluation in radiotherapy in real time. We present a new device and methodology that overcomes the traditional limitation of time-delay in radio...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: C. Guardiola, A. Márquez, M. C. Jiménez-Ramos, J. García López, A. Baratto-Roldán, X. Muñoz-Berbel
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/36c6904a35d24ba08f20d42db067cabf
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:36c6904a35d24ba08f20d42db067cabf
record_format dspace
spelling oai:doaj.org-article:36c6904a35d24ba08f20d42db067cabf2021-12-02T15:53:10ZDosimetry with gafchromic films based on a new micro-opto-electro-mechanical system10.1038/s41598-021-89602-92045-2322https://doaj.org/article/36c6904a35d24ba08f20d42db067cabf2021-05-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-89602-9https://doaj.org/toc/2045-2322Abstract This work presents the first tests performed with radiochromic films and a new Micro‒Opto‒Electro-Mechanical system (MOEMS) for in situ dosimetry evaluation in radiotherapy in real time. We present a new device and methodology that overcomes the traditional limitation of time-delay in radiochromic film analysis by turning a passive detector into an active sensor. The proposed system consists mainly of an optical sensor based on light emitting diodes and photodetectors controlled by both customized electronic circuit and graphical user interface, which enables optical measurements directly. We show the first trials performed in a low‒energy proton cyclotron with this MOEMS by using gafchromic EBT3 films. Results show the feasibility of using this system for in situ dose evaluations. Further adaptation is ongoing to develop a full real‒time active detector by integrating MOEM multi‒arrays and films in flexible printed circuits. Hence, we point to improve the clinical application of radiochromic films with the aim to optimize radiotherapy treatment verifications.C. GuardiolaA. MárquezM. C. Jiménez-RamosJ. García LópezA. Baratto-RoldánX. Muñoz-BerbelNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-11 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
C. Guardiola
A. Márquez
M. C. Jiménez-Ramos
J. García López
A. Baratto-Roldán
X. Muñoz-Berbel
Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system
description Abstract This work presents the first tests performed with radiochromic films and a new Micro‒Opto‒Electro-Mechanical system (MOEMS) for in situ dosimetry evaluation in radiotherapy in real time. We present a new device and methodology that overcomes the traditional limitation of time-delay in radiochromic film analysis by turning a passive detector into an active sensor. The proposed system consists mainly of an optical sensor based on light emitting diodes and photodetectors controlled by both customized electronic circuit and graphical user interface, which enables optical measurements directly. We show the first trials performed in a low‒energy proton cyclotron with this MOEMS by using gafchromic EBT3 films. Results show the feasibility of using this system for in situ dose evaluations. Further adaptation is ongoing to develop a full real‒time active detector by integrating MOEM multi‒arrays and films in flexible printed circuits. Hence, we point to improve the clinical application of radiochromic films with the aim to optimize radiotherapy treatment verifications.
format article
author C. Guardiola
A. Márquez
M. C. Jiménez-Ramos
J. García López
A. Baratto-Roldán
X. Muñoz-Berbel
author_facet C. Guardiola
A. Márquez
M. C. Jiménez-Ramos
J. García López
A. Baratto-Roldán
X. Muñoz-Berbel
author_sort C. Guardiola
title Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system
title_short Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system
title_full Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system
title_fullStr Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system
title_full_unstemmed Dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system
title_sort dosimetry with gafchromic films based on a new micro-opto-electro-mechanical system
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/36c6904a35d24ba08f20d42db067cabf
work_keys_str_mv AT cguardiola dosimetrywithgafchromicfilmsbasedonanewmicrooptoelectromechanicalsystem
AT amarquez dosimetrywithgafchromicfilmsbasedonanewmicrooptoelectromechanicalsystem
AT mcjimenezramos dosimetrywithgafchromicfilmsbasedonanewmicrooptoelectromechanicalsystem
AT jgarcialopez dosimetrywithgafchromicfilmsbasedonanewmicrooptoelectromechanicalsystem
AT abarattoroldan dosimetrywithgafchromicfilmsbasedonanewmicrooptoelectromechanicalsystem
AT xmunozberbel dosimetrywithgafchromicfilmsbasedonanewmicrooptoelectromechanicalsystem
_version_ 1718385503230754816