Psychometric test system for measuring cognitive reaction time

For the assessment of human reaction time, a test environment was developed. This system consists of an embedded device with organic light-emitting diode (OLED) displays with push buttons for the combined presentation of visual stimulation and registration of the haptic human reaction. The test lead...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Koch Klaus Peter, Laigle Hoffmann Julien, Jung Lukas, Auer Eric, Schächinger Hartmut
Formato: article
Lenguaje:EN
Publicado: De Gruyter 2020
Materias:
R
Acceso en línea:https://doaj.org/article/3774994777424b01860c7cf5182aedc7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:3774994777424b01860c7cf5182aedc7
record_format dspace
spelling oai:doaj.org-article:3774994777424b01860c7cf5182aedc72021-12-05T14:10:43ZPsychometric test system for measuring cognitive reaction time2364-550410.1515/cdbme-2020-3147https://doaj.org/article/3774994777424b01860c7cf5182aedc72020-09-01T00:00:00Zhttps://doi.org/10.1515/cdbme-2020-3147https://doaj.org/toc/2364-5504For the assessment of human reaction time, a test environment was developed. This system consists of an embedded device with organic light-emitting diode (OLED) displays with push buttons for the combined presentation of visual stimulation and registration of the haptic human reaction. The test leader can define the test sequence with the aid of a graphical user interface (GUI) on a personal computer (PC). The validation of the system was proved by measuring the latency times of the whole system, which are conditioned by the specific hard- and software constellation. Through the investigation of the display’s light radiation by a photodiode and the recorded current consumption, latency times and their variance were specified. In the fastest mode the system can reach an error limit of 60 μs.Koch Klaus PeterLaigle Hoffmann JulienJung LukasAuer EricSchächinger HartmutDe Gruyterarticlereaction time measurementcognitive performance assessmentoled latencyMedicineRENCurrent Directions in Biomedical Engineering, Vol 6, Iss 3, Pp 575-578 (2020)
institution DOAJ
collection DOAJ
language EN
topic reaction time measurement
cognitive performance assessment
oled latency
Medicine
R
spellingShingle reaction time measurement
cognitive performance assessment
oled latency
Medicine
R
Koch Klaus Peter
Laigle Hoffmann Julien
Jung Lukas
Auer Eric
Schächinger Hartmut
Psychometric test system for measuring cognitive reaction time
description For the assessment of human reaction time, a test environment was developed. This system consists of an embedded device with organic light-emitting diode (OLED) displays with push buttons for the combined presentation of visual stimulation and registration of the haptic human reaction. The test leader can define the test sequence with the aid of a graphical user interface (GUI) on a personal computer (PC). The validation of the system was proved by measuring the latency times of the whole system, which are conditioned by the specific hard- and software constellation. Through the investigation of the display’s light radiation by a photodiode and the recorded current consumption, latency times and their variance were specified. In the fastest mode the system can reach an error limit of 60 μs.
format article
author Koch Klaus Peter
Laigle Hoffmann Julien
Jung Lukas
Auer Eric
Schächinger Hartmut
author_facet Koch Klaus Peter
Laigle Hoffmann Julien
Jung Lukas
Auer Eric
Schächinger Hartmut
author_sort Koch Klaus Peter
title Psychometric test system for measuring cognitive reaction time
title_short Psychometric test system for measuring cognitive reaction time
title_full Psychometric test system for measuring cognitive reaction time
title_fullStr Psychometric test system for measuring cognitive reaction time
title_full_unstemmed Psychometric test system for measuring cognitive reaction time
title_sort psychometric test system for measuring cognitive reaction time
publisher De Gruyter
publishDate 2020
url https://doaj.org/article/3774994777424b01860c7cf5182aedc7
work_keys_str_mv AT kochklauspeter psychometrictestsystemformeasuringcognitivereactiontime
AT laiglehoffmannjulien psychometrictestsystemformeasuringcognitivereactiontime
AT junglukas psychometrictestsystemformeasuringcognitivereactiontime
AT auereric psychometrictestsystemformeasuringcognitivereactiontime
AT schachingerhartmut psychometrictestsystemformeasuringcognitivereactiontime
_version_ 1718371782910541824