Psychometric test system for measuring cognitive reaction time
For the assessment of human reaction time, a test environment was developed. This system consists of an embedded device with organic light-emitting diode (OLED) displays with push buttons for the combined presentation of visual stimulation and registration of the haptic human reaction. The test lead...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
De Gruyter
2020
|
Materias: | |
Acceso en línea: | https://doaj.org/article/3774994777424b01860c7cf5182aedc7 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:3774994777424b01860c7cf5182aedc7 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:3774994777424b01860c7cf5182aedc72021-12-05T14:10:43ZPsychometric test system for measuring cognitive reaction time2364-550410.1515/cdbme-2020-3147https://doaj.org/article/3774994777424b01860c7cf5182aedc72020-09-01T00:00:00Zhttps://doi.org/10.1515/cdbme-2020-3147https://doaj.org/toc/2364-5504For the assessment of human reaction time, a test environment was developed. This system consists of an embedded device with organic light-emitting diode (OLED) displays with push buttons for the combined presentation of visual stimulation and registration of the haptic human reaction. The test leader can define the test sequence with the aid of a graphical user interface (GUI) on a personal computer (PC). The validation of the system was proved by measuring the latency times of the whole system, which are conditioned by the specific hard- and software constellation. Through the investigation of the display’s light radiation by a photodiode and the recorded current consumption, latency times and their variance were specified. In the fastest mode the system can reach an error limit of 60 μs.Koch Klaus PeterLaigle Hoffmann JulienJung LukasAuer EricSchächinger HartmutDe Gruyterarticlereaction time measurementcognitive performance assessmentoled latencyMedicineRENCurrent Directions in Biomedical Engineering, Vol 6, Iss 3, Pp 575-578 (2020) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
reaction time measurement cognitive performance assessment oled latency Medicine R |
spellingShingle |
reaction time measurement cognitive performance assessment oled latency Medicine R Koch Klaus Peter Laigle Hoffmann Julien Jung Lukas Auer Eric Schächinger Hartmut Psychometric test system for measuring cognitive reaction time |
description |
For the assessment of human reaction time, a test environment was developed. This system consists of an embedded device with organic light-emitting diode (OLED) displays with push buttons for the combined presentation of visual stimulation and registration of the haptic human reaction. The test leader can define the test sequence with the aid of a graphical user interface (GUI) on a personal computer (PC). The validation of the system was proved by measuring the latency times of the whole system, which are conditioned by the specific hard- and software constellation. Through the investigation of the display’s light radiation by a photodiode and the recorded current consumption, latency times and their variance were specified. In the fastest mode the system can reach an error limit of 60 μs. |
format |
article |
author |
Koch Klaus Peter Laigle Hoffmann Julien Jung Lukas Auer Eric Schächinger Hartmut |
author_facet |
Koch Klaus Peter Laigle Hoffmann Julien Jung Lukas Auer Eric Schächinger Hartmut |
author_sort |
Koch Klaus Peter |
title |
Psychometric test system for measuring cognitive reaction time |
title_short |
Psychometric test system for measuring cognitive reaction time |
title_full |
Psychometric test system for measuring cognitive reaction time |
title_fullStr |
Psychometric test system for measuring cognitive reaction time |
title_full_unstemmed |
Psychometric test system for measuring cognitive reaction time |
title_sort |
psychometric test system for measuring cognitive reaction time |
publisher |
De Gruyter |
publishDate |
2020 |
url |
https://doaj.org/article/3774994777424b01860c7cf5182aedc7 |
work_keys_str_mv |
AT kochklauspeter psychometrictestsystemformeasuringcognitivereactiontime AT laiglehoffmannjulien psychometrictestsystemformeasuringcognitivereactiontime AT junglukas psychometrictestsystemformeasuringcognitivereactiontime AT auereric psychometrictestsystemformeasuringcognitivereactiontime AT schachingerhartmut psychometrictestsystemformeasuringcognitivereactiontime |
_version_ |
1718371782910541824 |