Design and Functionalization of a µPAD for the Enzymatic Determination of Nitrate in Urine

In this work, the design of a microfluidic paper-based analytical device (μPAD) for the quantification of nitrate in urine samples was described. Nitrate monitoring is highly relevant due to its association to some diseases and health conditions. The nitrate determination was achieved by combining t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Francisca T. S. M. Ferreira, Raquel B. R. Mesquita, António O. S. S. Rangel
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/38246f7c79d24838b9bb279ef3126114
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:38246f7c79d24838b9bb279ef3126114
record_format dspace
spelling oai:doaj.org-article:38246f7c79d24838b9bb279ef31261142021-11-11T18:23:06ZDesign and Functionalization of a µPAD for the Enzymatic Determination of Nitrate in Urine10.3390/molecules262163551420-3049https://doaj.org/article/38246f7c79d24838b9bb279ef31261142021-10-01T00:00:00Zhttps://www.mdpi.com/1420-3049/26/21/6355https://doaj.org/toc/1420-3049In this work, the design of a microfluidic paper-based analytical device (μPAD) for the quantification of nitrate in urine samples was described. Nitrate monitoring is highly relevant due to its association to some diseases and health conditions. The nitrate determination was achieved by combining the selectivity of the nitrate reductase enzymatic reaction with the colorimetric detection of nitrite by the well-known Griess reagent. For the optimization of the nitrate determination μPAD, several variables associated with the design and construction of the device were studied. Furthermore, the interference of the urine matrix was evaluated, and stability studies were performed, under different conditions. The developed μPAD enabled us to obtain a limit of detection of 0.04 mM, a limit of quantification of 0.14 mM and a dynamic concentration range of 0.14–1.0 mM. The designed μPAD proved to be stable for 24 h when stored at room temperature in air or vacuum atmosphere, and 60 days when stored in vacuum at −20 °C. The accuracy of the nitrate μPAD measurements was confirmed by analyzing four certified samples (prepared in synthetic urine) and performing recovery studies using urine samples.Francisca T. S. M. FerreiraRaquel B. R. MesquitaAntónio O. S. S. RangelMDPI AGarticlemicrofluidic paper-based devicenitrate reductasehydrophilic membraneGriess reactionurine samplesOrganic chemistryQD241-441ENMolecules, Vol 26, Iss 6355, p 6355 (2021)
institution DOAJ
collection DOAJ
language EN
topic microfluidic paper-based device
nitrate reductase
hydrophilic membrane
Griess reaction
urine samples
Organic chemistry
QD241-441
spellingShingle microfluidic paper-based device
nitrate reductase
hydrophilic membrane
Griess reaction
urine samples
Organic chemistry
QD241-441
Francisca T. S. M. Ferreira
Raquel B. R. Mesquita
António O. S. S. Rangel
Design and Functionalization of a µPAD for the Enzymatic Determination of Nitrate in Urine
description In this work, the design of a microfluidic paper-based analytical device (μPAD) for the quantification of nitrate in urine samples was described. Nitrate monitoring is highly relevant due to its association to some diseases and health conditions. The nitrate determination was achieved by combining the selectivity of the nitrate reductase enzymatic reaction with the colorimetric detection of nitrite by the well-known Griess reagent. For the optimization of the nitrate determination μPAD, several variables associated with the design and construction of the device were studied. Furthermore, the interference of the urine matrix was evaluated, and stability studies were performed, under different conditions. The developed μPAD enabled us to obtain a limit of detection of 0.04 mM, a limit of quantification of 0.14 mM and a dynamic concentration range of 0.14–1.0 mM. The designed μPAD proved to be stable for 24 h when stored at room temperature in air or vacuum atmosphere, and 60 days when stored in vacuum at −20 °C. The accuracy of the nitrate μPAD measurements was confirmed by analyzing four certified samples (prepared in synthetic urine) and performing recovery studies using urine samples.
format article
author Francisca T. S. M. Ferreira
Raquel B. R. Mesquita
António O. S. S. Rangel
author_facet Francisca T. S. M. Ferreira
Raquel B. R. Mesquita
António O. S. S. Rangel
author_sort Francisca T. S. M. Ferreira
title Design and Functionalization of a µPAD for the Enzymatic Determination of Nitrate in Urine
title_short Design and Functionalization of a µPAD for the Enzymatic Determination of Nitrate in Urine
title_full Design and Functionalization of a µPAD for the Enzymatic Determination of Nitrate in Urine
title_fullStr Design and Functionalization of a µPAD for the Enzymatic Determination of Nitrate in Urine
title_full_unstemmed Design and Functionalization of a µPAD for the Enzymatic Determination of Nitrate in Urine
title_sort design and functionalization of a µpad for the enzymatic determination of nitrate in urine
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/38246f7c79d24838b9bb279ef3126114
work_keys_str_mv AT franciscatsmferreira designandfunctionalizationofaμpadfortheenzymaticdeterminationofnitrateinurine
AT raquelbrmesquita designandfunctionalizationofaμpadfortheenzymaticdeterminationofnitrateinurine
AT antonioossrangel designandfunctionalizationofaμpadfortheenzymaticdeterminationofnitrateinurine
_version_ 1718431816885469184