THE EXPERIMENTAL VALIDATION OF THE GROUNDING DEVICE RESISTANCE MEASUREMENT METHOD
Purpose. The paper considers experimental research of three-electrode units for measuring the resistance of grounding devices for different purposes. Methodology. The experimental study of the method of resistance measurement of grounding devices for any design in any soil structure using the method...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN RU UK |
Publicado: |
National Technical University "Kharkiv Polytechnic Institute"
2016
|
Materias: | |
Acceso en línea: | https://doaj.org/article/384e729789a940b789339bc7004da1c8 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:384e729789a940b789339bc7004da1c8 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:384e729789a940b789339bc7004da1c82021-12-02T14:57:02ZTHE EXPERIMENTAL VALIDATION OF THE GROUNDING DEVICE RESISTANCE MEASUREMENT METHOD10.20998/2074-272X.2016.6.102074-272X2309-3404https://doaj.org/article/384e729789a940b789339bc7004da1c82016-12-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2016.6.10/82191https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. The paper considers experimental research of three-electrode units for measuring the resistance of grounding devices for different purposes. Methodology. The experimental study of the method of resistance measurement of grounding devices for any design in any soil structure using the method of physical modeling is presented. Results. By results of model operation the set of equations of the sixth order is solved. It allowed to determine the own and mutual impedance in the three-electrode unit with high accuracy without searching the point of zero potential. Features of measuring and defining the own and relative resistances of various combinations of electrodes for three-electrode measuring unit are considered. Originality. The necessity of finding a zero potential point is excluded. Practical value. The proposed method provides the smallest possible spacing of potential electrodes outside the grounding devices. This reduces the wiring length measurement circuit in several times, increases the ratio «signal – noise», removes the restrictions on building of the territory outside the test grounding device. I. V. NizhevskyiV. I. NizhevskyiV. E. Bondarenko National Technical University "Kharkiv Polytechnic Institute"articleexperimental researchgrounding devicethe resistance measurement methodthree-electrode unitthe method of physical modelingexperimental validationElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 6, Pp 60-64 (2016) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN RU UK |
topic |
experimental research grounding device the resistance measurement method three-electrode unit the method of physical modeling experimental validation Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
experimental research grounding device the resistance measurement method three-electrode unit the method of physical modeling experimental validation Electrical engineering. Electronics. Nuclear engineering TK1-9971 I. V. Nizhevskyi V. I. Nizhevskyi V. E. Bondarenko THE EXPERIMENTAL VALIDATION OF THE GROUNDING DEVICE RESISTANCE MEASUREMENT METHOD |
description |
Purpose. The paper considers experimental research of three-electrode units for measuring the resistance of grounding devices for different purposes. Methodology. The experimental study of the method of resistance measurement of grounding devices for any design in any soil structure using the method of physical modeling is presented. Results. By results of model operation the set of equations of the sixth order is solved. It allowed to determine the own and mutual impedance in the three-electrode unit with high accuracy without searching the point of zero potential. Features of measuring and defining the own and relative resistances of various combinations of electrodes for three-electrode measuring unit are considered. Originality. The necessity of finding a zero potential point is excluded. Practical value. The proposed method provides the smallest possible spacing of potential electrodes outside the grounding devices. This reduces the wiring length measurement circuit in several times, increases the ratio «signal – noise», removes the restrictions on building of the territory outside the test grounding device. |
format |
article |
author |
I. V. Nizhevskyi V. I. Nizhevskyi V. E. Bondarenko |
author_facet |
I. V. Nizhevskyi V. I. Nizhevskyi V. E. Bondarenko |
author_sort |
I. V. Nizhevskyi |
title |
THE EXPERIMENTAL VALIDATION OF THE GROUNDING DEVICE RESISTANCE MEASUREMENT METHOD |
title_short |
THE EXPERIMENTAL VALIDATION OF THE GROUNDING DEVICE RESISTANCE MEASUREMENT METHOD |
title_full |
THE EXPERIMENTAL VALIDATION OF THE GROUNDING DEVICE RESISTANCE MEASUREMENT METHOD |
title_fullStr |
THE EXPERIMENTAL VALIDATION OF THE GROUNDING DEVICE RESISTANCE MEASUREMENT METHOD |
title_full_unstemmed |
THE EXPERIMENTAL VALIDATION OF THE GROUNDING DEVICE RESISTANCE MEASUREMENT METHOD |
title_sort |
experimental validation of the grounding device resistance measurement method |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
publishDate |
2016 |
url |
https://doaj.org/article/384e729789a940b789339bc7004da1c8 |
work_keys_str_mv |
AT ivnizhevskyi theexperimentalvalidationofthegroundingdeviceresistancemeasurementmethod AT vinizhevskyi theexperimentalvalidationofthegroundingdeviceresistancemeasurementmethod AT vebondarenko theexperimentalvalidationofthegroundingdeviceresistancemeasurementmethod AT ivnizhevskyi experimentalvalidationofthegroundingdeviceresistancemeasurementmethod AT vinizhevskyi experimentalvalidationofthegroundingdeviceresistancemeasurementmethod AT vebondarenko experimentalvalidationofthegroundingdeviceresistancemeasurementmethod |
_version_ |
1718389317486772224 |