An automated mammogram classification system using modified support vector machine

Aderonke Anthonia Kayode,1 Noah Oluwatobi Akande,1 Adekanmi Adeyinka Adegun,1 Marion Olubunmi Adebiyi21Computer Science Department, Landmark University, Omu-Aran, Kwara State, Nigeria; 2Department of Computer and Information Sciences, Covenant University, Ota, Ogun State, NigeriaPurpose: Breast canc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kayode AA, Akande NO, Adegun AA, Adebiyi MO
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://doaj.org/article/38c16044dfdf48f28c0f693ffaeeade9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:38c16044dfdf48f28c0f693ffaeeade9
record_format dspace
spelling oai:doaj.org-article:38c16044dfdf48f28c0f693ffaeeade92021-12-02T09:15:34ZAn automated mammogram classification system using modified support vector machine1179-1470https://doaj.org/article/38c16044dfdf48f28c0f693ffaeeade92019-08-01T00:00:00Zhttps://www.dovepress.com/an-automated-mammogram-classification-system-using-modified-support-ve-peer-reviewed-article-MDERhttps://doaj.org/toc/1179-1470Aderonke Anthonia Kayode,1 Noah Oluwatobi Akande,1 Adekanmi Adeyinka Adegun,1 Marion Olubunmi Adebiyi21Computer Science Department, Landmark University, Omu-Aran, Kwara State, Nigeria; 2Department of Computer and Information Sciences, Covenant University, Ota, Ogun State, NigeriaPurpose: Breast cancer remains a serious public health problem that results in the loss of lives among women. However, early detection of its signs increases treatment options and the likelihood of cure. Although mammography has been established to be a proven technique of examining symptoms of cancer in mammograms, the manual observation by radiologists is demanding and often prone to diagnostic errors. Therefore, computer aided diagnosis (CADx) systems could be a viable alternative that could facilitate and ease cancer diagnosis process; hence this study.Methodology: The inputs to the proposed model are raw mammograms downloaded from the Mammographic Image Analysis Society database. Prior to the classification, the raw mammograms were preprocessed. Then, gray level co-occurrence matrix was used to extract fifteen textural features from the mammograms at four different angular directions: θ={0°, 45°, 90°, 135°}, and two distances: D={1,2}. Afterwards, a two-stage support vector machine was used to classify the mammograms as normal, benign and malignant.Results: All of the 37 normal images used as test data were classified as normal (no false positive) and all 41 abnormal images were correctly classified to be abnormal (no false negative), meaning that the sensitivity and specificity of the model in detecting abnormality is 100%. After the detection of abnormality, the system further classified the abnormality on the mammograms to be either “benign” or “malignant”. Out of 23 benign images, 21 were truly classified as benign. Also, out of 18 malignant images, 17 were truly classified to be malignant. From these findings, the sensitivity, specificity, positive predictive value, and negative predictive value of the system are 94.4%, 91.3%, 89.5%, and 95.5%, respectively.Conclusion: This article has further affirmed the prowess of automated CADx systems as a viable tool that could facilitate breast cancer diagnosis by radiologists.Keywords: cancer diagnosis, CADx systems, radiologists, diagnostic errors, GLCMKayode AAAkande NOAdegun AAAdebiyi MODove Medical PressarticleCancer diagnosisCAD systemsRadiologistsDiagnostic errorsGray level co-occurrence matrixMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol Volume 12, Pp 275-284 (2019)
institution DOAJ
collection DOAJ
language EN
topic Cancer diagnosis
CAD systems
Radiologists
Diagnostic errors
Gray level co-occurrence matrix
Medical technology
R855-855.5
spellingShingle Cancer diagnosis
CAD systems
Radiologists
Diagnostic errors
Gray level co-occurrence matrix
Medical technology
R855-855.5
Kayode AA
Akande NO
Adegun AA
Adebiyi MO
An automated mammogram classification system using modified support vector machine
description Aderonke Anthonia Kayode,1 Noah Oluwatobi Akande,1 Adekanmi Adeyinka Adegun,1 Marion Olubunmi Adebiyi21Computer Science Department, Landmark University, Omu-Aran, Kwara State, Nigeria; 2Department of Computer and Information Sciences, Covenant University, Ota, Ogun State, NigeriaPurpose: Breast cancer remains a serious public health problem that results in the loss of lives among women. However, early detection of its signs increases treatment options and the likelihood of cure. Although mammography has been established to be a proven technique of examining symptoms of cancer in mammograms, the manual observation by radiologists is demanding and often prone to diagnostic errors. Therefore, computer aided diagnosis (CADx) systems could be a viable alternative that could facilitate and ease cancer diagnosis process; hence this study.Methodology: The inputs to the proposed model are raw mammograms downloaded from the Mammographic Image Analysis Society database. Prior to the classification, the raw mammograms were preprocessed. Then, gray level co-occurrence matrix was used to extract fifteen textural features from the mammograms at four different angular directions: θ={0°, 45°, 90°, 135°}, and two distances: D={1,2}. Afterwards, a two-stage support vector machine was used to classify the mammograms as normal, benign and malignant.Results: All of the 37 normal images used as test data were classified as normal (no false positive) and all 41 abnormal images were correctly classified to be abnormal (no false negative), meaning that the sensitivity and specificity of the model in detecting abnormality is 100%. After the detection of abnormality, the system further classified the abnormality on the mammograms to be either “benign” or “malignant”. Out of 23 benign images, 21 were truly classified as benign. Also, out of 18 malignant images, 17 were truly classified to be malignant. From these findings, the sensitivity, specificity, positive predictive value, and negative predictive value of the system are 94.4%, 91.3%, 89.5%, and 95.5%, respectively.Conclusion: This article has further affirmed the prowess of automated CADx systems as a viable tool that could facilitate breast cancer diagnosis by radiologists.Keywords: cancer diagnosis, CADx systems, radiologists, diagnostic errors, GLCM
format article
author Kayode AA
Akande NO
Adegun AA
Adebiyi MO
author_facet Kayode AA
Akande NO
Adegun AA
Adebiyi MO
author_sort Kayode AA
title An automated mammogram classification system using modified support vector machine
title_short An automated mammogram classification system using modified support vector machine
title_full An automated mammogram classification system using modified support vector machine
title_fullStr An automated mammogram classification system using modified support vector machine
title_full_unstemmed An automated mammogram classification system using modified support vector machine
title_sort automated mammogram classification system using modified support vector machine
publisher Dove Medical Press
publishDate 2019
url https://doaj.org/article/38c16044dfdf48f28c0f693ffaeeade9
work_keys_str_mv AT kayodeaa anautomatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT akandeno anautomatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT adegunaa anautomatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT adebiyimo anautomatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT kayodeaa automatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT akandeno automatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT adegunaa automatedmammogramclassificationsystemusingmodifiedsupportvectormachine
AT adebiyimo automatedmammogramclassificationsystemusingmodifiedsupportvectormachine
_version_ 1718398178439462912