A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function
<italic>Goal:</italic> Current instruments for bulbar assessment exhibit technical limitations that hinder the execution of clinical studies. The volume conduction properties (VCP) of the tongue reflect ionic content and myofiber integrity and they can serve as a new biomarker for evalua...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
IEEE
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/39fefe66a5e74c9eadce92f533ff654b |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:39fefe66a5e74c9eadce92f533ff654b |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:39fefe66a5e74c9eadce92f533ff654b2021-11-24T00:04:02ZA Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function2644-127610.1109/OJEMB.2021.3117871https://doaj.org/article/39fefe66a5e74c9eadce92f533ff654b2021-01-01T00:00:00Zhttps://ieeexplore.ieee.org/document/9560103/https://doaj.org/toc/2644-1276<italic>Goal:</italic> Current instruments for bulbar assessment exhibit technical limitations that hinder the execution of clinical studies. The volume conduction properties (VCP) of the tongue reflect ionic content and myofiber integrity and they can serve as a new biomarker for evaluating neurological disorders with bulbar dysfunction. <italic>Methods:</italic> We designed a standalone bioimpedance measurement system that enables accurate, multi-frequency measurement of tongue anisotropic VCP including conductivity and relative permittivity. The system includes a tongue depressor with 16 non-invasive surface sensors for electrical contact with the tongue at directions 0<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>, 45<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>, 90<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula> and 150<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>. The depressor is interfaced with the tongue electronic system with Bluetooth connectivity, and a smartphone application. De-identified patient data is sent by email. <italic>Results:</italic> We first determined the accuracy of the hardware performing phantom measurements mimicking a broad range of tongue values and determined the error to be <inline-formula><tex-math notation="LaTeX">$< $</tex-math></inline-formula>1%. We then validated our new technology measuring a cohort of 7 healthy human subjects under Institutional Review Board approval. <italic>Conclusions:</italic> None of the subjects who participated suffered discomfort or gag reflexes. The novel technique presented for intra-oral assessment of tongue VCP provides standard, objective and quantitative data potentially sensitive to alterations in tongue internal structure and composition.Xuesong LuoHilda Victoria Gutierrez PulidoSeward RutkoveBenjamin SanchezIEEEarticleTonguevolume conduction propertiesanisotropyelectrodesbiomarkerComputer applications to medicine. Medical informaticsR858-859.7Medical technologyR855-855.5ENIEEE Open Journal of Engineering in Medicine and Biology, Vol 2, Pp 278-285 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Tongue volume conduction properties anisotropy electrodes biomarker Computer applications to medicine. Medical informatics R858-859.7 Medical technology R855-855.5 |
spellingShingle |
Tongue volume conduction properties anisotropy electrodes biomarker Computer applications to medicine. Medical informatics R858-859.7 Medical technology R855-855.5 Xuesong Luo Hilda Victoria Gutierrez Pulido Seward Rutkove Benjamin Sanchez A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function |
description |
<italic>Goal:</italic> Current instruments for bulbar assessment exhibit technical limitations that hinder the execution of clinical studies. The volume conduction properties (VCP) of the tongue reflect ionic content and myofiber integrity and they can serve as a new biomarker for evaluating neurological disorders with bulbar dysfunction. <italic>Methods:</italic> We designed a standalone bioimpedance measurement system that enables accurate, multi-frequency measurement of tongue anisotropic VCP including conductivity and relative permittivity. The system includes a tongue depressor with 16 non-invasive surface sensors for electrical contact with the tongue at directions 0<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>, 45<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>, 90<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula> and 150<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>. The depressor is interfaced with the tongue electronic system with Bluetooth connectivity, and a smartphone application. De-identified patient data is sent by email. <italic>Results:</italic> We first determined the accuracy of the hardware performing phantom measurements mimicking a broad range of tongue values and determined the error to be <inline-formula><tex-math notation="LaTeX">$< $</tex-math></inline-formula>1%. We then validated our new technology measuring a cohort of 7 healthy human subjects under Institutional Review Board approval. <italic>Conclusions:</italic> None of the subjects who participated suffered discomfort or gag reflexes. The novel technique presented for intra-oral assessment of tongue VCP provides standard, objective and quantitative data potentially sensitive to alterations in tongue internal structure and composition. |
format |
article |
author |
Xuesong Luo Hilda Victoria Gutierrez Pulido Seward Rutkove Benjamin Sanchez |
author_facet |
Xuesong Luo Hilda Victoria Gutierrez Pulido Seward Rutkove Benjamin Sanchez |
author_sort |
Xuesong Luo |
title |
A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function |
title_short |
A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function |
title_full |
A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function |
title_fullStr |
A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function |
title_full_unstemmed |
A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function |
title_sort |
bioimpedance-based device to assess the volume conduction properties of the tongue in neurological disorders affecting bulbar function |
publisher |
IEEE |
publishDate |
2021 |
url |
https://doaj.org/article/39fefe66a5e74c9eadce92f533ff654b |
work_keys_str_mv |
AT xuesongluo abioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction AT hildavictoriagutierrezpulido abioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction AT sewardrutkove abioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction AT benjaminsanchez abioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction AT xuesongluo bioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction AT hildavictoriagutierrezpulido bioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction AT sewardrutkove bioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction AT benjaminsanchez bioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction |
_version_ |
1718416086987177984 |