A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function

<italic>Goal:</italic> Current instruments for bulbar assessment exhibit technical limitations that hinder the execution of clinical studies. The volume conduction properties (VCP) of the tongue reflect ionic content and myofiber integrity and they can serve as a new biomarker for evalua...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Xuesong Luo, Hilda Victoria Gutierrez Pulido, Seward Rutkove, Benjamin Sanchez
Formato: article
Lenguaje:EN
Publicado: IEEE 2021
Materias:
Acceso en línea:https://doaj.org/article/39fefe66a5e74c9eadce92f533ff654b
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:39fefe66a5e74c9eadce92f533ff654b
record_format dspace
spelling oai:doaj.org-article:39fefe66a5e74c9eadce92f533ff654b2021-11-24T00:04:02ZA Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function2644-127610.1109/OJEMB.2021.3117871https://doaj.org/article/39fefe66a5e74c9eadce92f533ff654b2021-01-01T00:00:00Zhttps://ieeexplore.ieee.org/document/9560103/https://doaj.org/toc/2644-1276<italic>Goal:</italic> Current instruments for bulbar assessment exhibit technical limitations that hinder the execution of clinical studies. The volume conduction properties (VCP) of the tongue reflect ionic content and myofiber integrity and they can serve as a new biomarker for evaluating neurological disorders with bulbar dysfunction. <italic>Methods:</italic> We designed a standalone bioimpedance measurement system that enables accurate, multi-frequency measurement of tongue anisotropic VCP including conductivity and relative permittivity. The system includes a tongue depressor with 16 non-invasive surface sensors for electrical contact with the tongue at directions 0<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>, 45<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>, 90<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula> and 150<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>. The depressor is interfaced with the tongue electronic system with Bluetooth connectivity, and a smartphone application. De-identified patient data is sent by email. <italic>Results:</italic> We first determined the accuracy of the hardware performing phantom measurements mimicking a broad range of tongue values and determined the error to be <inline-formula><tex-math notation="LaTeX">$&lt; $</tex-math></inline-formula>1%. We then validated our new technology measuring a cohort of 7 healthy human subjects under Institutional Review Board approval. <italic>Conclusions:</italic> None of the subjects who participated suffered discomfort or gag reflexes. The novel technique presented for intra-oral assessment of tongue VCP provides standard, objective and quantitative data potentially sensitive to alterations in tongue internal structure and composition.Xuesong LuoHilda Victoria Gutierrez PulidoSeward RutkoveBenjamin SanchezIEEEarticleTonguevolume conduction propertiesanisotropyelectrodesbiomarkerComputer applications to medicine. Medical informaticsR858-859.7Medical technologyR855-855.5ENIEEE Open Journal of Engineering in Medicine and Biology, Vol 2, Pp 278-285 (2021)
institution DOAJ
collection DOAJ
language EN
topic Tongue
volume conduction properties
anisotropy
electrodes
biomarker
Computer applications to medicine. Medical informatics
R858-859.7
Medical technology
R855-855.5
spellingShingle Tongue
volume conduction properties
anisotropy
electrodes
biomarker
Computer applications to medicine. Medical informatics
R858-859.7
Medical technology
R855-855.5
Xuesong Luo
Hilda Victoria Gutierrez Pulido
Seward Rutkove
Benjamin Sanchez
A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function
description <italic>Goal:</italic> Current instruments for bulbar assessment exhibit technical limitations that hinder the execution of clinical studies. The volume conduction properties (VCP) of the tongue reflect ionic content and myofiber integrity and they can serve as a new biomarker for evaluating neurological disorders with bulbar dysfunction. <italic>Methods:</italic> We designed a standalone bioimpedance measurement system that enables accurate, multi-frequency measurement of tongue anisotropic VCP including conductivity and relative permittivity. The system includes a tongue depressor with 16 non-invasive surface sensors for electrical contact with the tongue at directions 0<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>, 45<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>, 90<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula> and 150<inline-formula><tex-math notation="LaTeX">$^{\circ }$</tex-math></inline-formula>. The depressor is interfaced with the tongue electronic system with Bluetooth connectivity, and a smartphone application. De-identified patient data is sent by email. <italic>Results:</italic> We first determined the accuracy of the hardware performing phantom measurements mimicking a broad range of tongue values and determined the error to be <inline-formula><tex-math notation="LaTeX">$&lt; $</tex-math></inline-formula>1%. We then validated our new technology measuring a cohort of 7 healthy human subjects under Institutional Review Board approval. <italic>Conclusions:</italic> None of the subjects who participated suffered discomfort or gag reflexes. The novel technique presented for intra-oral assessment of tongue VCP provides standard, objective and quantitative data potentially sensitive to alterations in tongue internal structure and composition.
format article
author Xuesong Luo
Hilda Victoria Gutierrez Pulido
Seward Rutkove
Benjamin Sanchez
author_facet Xuesong Luo
Hilda Victoria Gutierrez Pulido
Seward Rutkove
Benjamin Sanchez
author_sort Xuesong Luo
title A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function
title_short A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function
title_full A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function
title_fullStr A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function
title_full_unstemmed A Bioimpedance-Based Device to Assess the Volume Conduction Properties of the Tongue in Neurological Disorders Affecting Bulbar function
title_sort bioimpedance-based device to assess the volume conduction properties of the tongue in neurological disorders affecting bulbar function
publisher IEEE
publishDate 2021
url https://doaj.org/article/39fefe66a5e74c9eadce92f533ff654b
work_keys_str_mv AT xuesongluo abioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction
AT hildavictoriagutierrezpulido abioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction
AT sewardrutkove abioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction
AT benjaminsanchez abioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction
AT xuesongluo bioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction
AT hildavictoriagutierrezpulido bioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction
AT sewardrutkove bioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction
AT benjaminsanchez bioimpedancebaseddevicetoassessthevolumeconductionpropertiesofthetongueinneurologicaldisordersaffectingbulbarfunction
_version_ 1718416086987177984