Improvement of a test-system for the botulinus toxin screening in dot-immunoanalysis

We constructed a test system for dot-immunoassay (DIA) to accelerate definition and identification of botulinus toxins and also to refuse from application of laboratory animals for routine screening of clinical samples, foodstuff and environments. This system permitted to detect botulinus toxin duri...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: T. Yu. Zagoskina, E. A. Chaporgina, E. Yu. Markov, Yu. O. Popova, S. Yu. Solovyev, N. M. Andreevskaya, S. V. Balakhonov
Formato: article
Lenguaje:RU
Publicado: Scientific Сentre for Family Health and Human Reproduction Problems 2015
Materias:
Q
Acceso en línea:https://doaj.org/article/3e01634eb5b047a79dfbcf28813a5c7e
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:3e01634eb5b047a79dfbcf28813a5c7e
record_format dspace
spelling oai:doaj.org-article:3e01634eb5b047a79dfbcf28813a5c7e2021-11-23T06:14:31ZImprovement of a test-system for the botulinus toxin screening in dot-immunoanalysis2541-94202587-9596https://doaj.org/article/3e01634eb5b047a79dfbcf28813a5c7e2015-02-01T00:00:00Zhttps://www.actabiomedica.ru/jour/article/view/12https://doaj.org/toc/2541-9420https://doaj.org/toc/2587-9596We constructed a test system for dot-immunoassay (DIA) to accelerate definition and identification of botulinus toxins and also to refuse from application of laboratory animals for routine screening of clinical samples, foodstuff and environments. This system permitted to detect botulinus toxin during approximately 2 h in the tested samples. Sensitivity of this DIA in some cases exceeded the mice biotest. This improved method has minimum reaction to nonspecific exposures from the investigated biological substrata. It is simple to conduct. It is high efficient and expressive, does not require to use expensive equipment and the reactants, special training for the personnel. Lyophilization conditions for the immune reagents used for the test system preparation for botulinus toxin dot-immunoassay were selected. High sensitivity, specificity of the analysis are remained, stability of the preparations (periods of storage) is increased. This method is convenient to use in field conditions at extreme situations, in particular, in mobile autolaboratories for epidemiological survey.T. Yu. ZagoskinaE. A. ChaporginaE. Yu. MarkovYu. O. PopovaS. Yu. SolovyevN. M. AndreevskayaS. V. BalakhonovScientific Сentre for Family Health and Human Reproduction Problemsarticlespecific immunoglobulinscolloid silverdot-immunoanalysisbotulinus toxinScienceQRUActa Biomedica Scientifica, Vol 0, Iss 1, Pp 60-62 (2015)
institution DOAJ
collection DOAJ
language RU
topic specific immunoglobulins
colloid silver
dot-immunoanalysis
botulinus toxin
Science
Q
spellingShingle specific immunoglobulins
colloid silver
dot-immunoanalysis
botulinus toxin
Science
Q
T. Yu. Zagoskina
E. A. Chaporgina
E. Yu. Markov
Yu. O. Popova
S. Yu. Solovyev
N. M. Andreevskaya
S. V. Balakhonov
Improvement of a test-system for the botulinus toxin screening in dot-immunoanalysis
description We constructed a test system for dot-immunoassay (DIA) to accelerate definition and identification of botulinus toxins and also to refuse from application of laboratory animals for routine screening of clinical samples, foodstuff and environments. This system permitted to detect botulinus toxin during approximately 2 h in the tested samples. Sensitivity of this DIA in some cases exceeded the mice biotest. This improved method has minimum reaction to nonspecific exposures from the investigated biological substrata. It is simple to conduct. It is high efficient and expressive, does not require to use expensive equipment and the reactants, special training for the personnel. Lyophilization conditions for the immune reagents used for the test system preparation for botulinus toxin dot-immunoassay were selected. High sensitivity, specificity of the analysis are remained, stability of the preparations (periods of storage) is increased. This method is convenient to use in field conditions at extreme situations, in particular, in mobile autolaboratories for epidemiological survey.
format article
author T. Yu. Zagoskina
E. A. Chaporgina
E. Yu. Markov
Yu. O. Popova
S. Yu. Solovyev
N. M. Andreevskaya
S. V. Balakhonov
author_facet T. Yu. Zagoskina
E. A. Chaporgina
E. Yu. Markov
Yu. O. Popova
S. Yu. Solovyev
N. M. Andreevskaya
S. V. Balakhonov
author_sort T. Yu. Zagoskina
title Improvement of a test-system for the botulinus toxin screening in dot-immunoanalysis
title_short Improvement of a test-system for the botulinus toxin screening in dot-immunoanalysis
title_full Improvement of a test-system for the botulinus toxin screening in dot-immunoanalysis
title_fullStr Improvement of a test-system for the botulinus toxin screening in dot-immunoanalysis
title_full_unstemmed Improvement of a test-system for the botulinus toxin screening in dot-immunoanalysis
title_sort improvement of a test-system for the botulinus toxin screening in dot-immunoanalysis
publisher Scientific Сentre for Family Health and Human Reproduction Problems
publishDate 2015
url https://doaj.org/article/3e01634eb5b047a79dfbcf28813a5c7e
work_keys_str_mv AT tyuzagoskina improvementofatestsystemforthebotulinustoxinscreeningindotimmunoanalysis
AT eachaporgina improvementofatestsystemforthebotulinustoxinscreeningindotimmunoanalysis
AT eyumarkov improvementofatestsystemforthebotulinustoxinscreeningindotimmunoanalysis
AT yuopopova improvementofatestsystemforthebotulinustoxinscreeningindotimmunoanalysis
AT syusolovyev improvementofatestsystemforthebotulinustoxinscreeningindotimmunoanalysis
AT nmandreevskaya improvementofatestsystemforthebotulinustoxinscreeningindotimmunoanalysis
AT svbalakhonov improvementofatestsystemforthebotulinustoxinscreeningindotimmunoanalysis
_version_ 1718417111266623488