Dynamics of Blood Values in Patients with Radial Shaft Injury after Using Transosseous Osteosynthesis by external Fixation Pin Device

Transosseous osteosynthesis continues to occupy a leading position among the methods of treatment of damage to the tubular bones of the extremities. This article presents a survey of 47 patients: 22 men and 25 women aged 25 to 60 years with fractures in the middle third of the radial shaft with disp...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: I. N. Kinash, M. E. Puseva, Ch. Z. Butaev, E. G. Ippolitova
Formato: article
Lenguaje:RU
Publicado: Scientific Сentre for Family Health and Human Reproduction Problems 2019
Materias:
Q
Acceso en línea:https://doaj.org/article/3ea197e6f1294a4d8e8eda4ef0c30ecf
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:3ea197e6f1294a4d8e8eda4ef0c30ecf
record_format dspace
spelling oai:doaj.org-article:3ea197e6f1294a4d8e8eda4ef0c30ecf2021-11-23T06:14:41ZDynamics of Blood Values in Patients with Radial Shaft Injury after Using Transosseous Osteosynthesis by external Fixation Pin Device2541-94202587-959610.29413/ABS.2018-3.6.13https://doaj.org/article/3ea197e6f1294a4d8e8eda4ef0c30ecf2019-01-01T00:00:00Zhttps://www.actabiomedica.ru/jour/article/view/1887https://doaj.org/toc/2541-9420https://doaj.org/toc/2587-9596Transosseous osteosynthesis continues to occupy a leading position among the methods of treatment of damage to the tubular bones of the extremities. This article presents a survey of 47 patients: 22 men and 25 women aged 25 to 60 years with fractures in the middle third of the radial shaft with displacement of bone fragments. The peculiarity of the external fixation device we used is that all transosseous elements are represented by 1.5 mm pins, inserted through both cortical layers of each bone, at levels from I and VIII. The pins are inserted simultaneously through both bones, thus excluding the rotational function of the forearm.The essence of the study is a comparative analysis of the blood system parameters in patients with diaphyseal injuries of the radial bone, operated by the transosseous osteosynthesis method using the external fixation device of pin configuration. Any damage to the body, (a fracture or related surgery), is accompanied with various changes in the system of hemodynamics and metabolism.The laboratory blood tests performed in the group of patients with damage to the radial shaft treated with transosseous osteosynthesis by external fixation device of pin configuration, revealed certain regularities in changing of blood parameters: increased number of platelets, increased level of fibrinogen and level of soluble fibrin complexes, which promotes the activation of the internal mechanism of blood clotting.I. N. KinashM. E. PusevaCh. Z. ButaevE. G. IppolitovaScientific Сentre for Family Health and Human Reproduction Problemsarticleplateletsfibrinogensoluble fibrin complexesScienceQRUActa Biomedica Scientifica, Vol 3, Iss 6, Pp 95-99 (2019)
institution DOAJ
collection DOAJ
language RU
topic platelets
fibrinogen
soluble fibrin complexes
Science
Q
spellingShingle platelets
fibrinogen
soluble fibrin complexes
Science
Q
I. N. Kinash
M. E. Puseva
Ch. Z. Butaev
E. G. Ippolitova
Dynamics of Blood Values in Patients with Radial Shaft Injury after Using Transosseous Osteosynthesis by external Fixation Pin Device
description Transosseous osteosynthesis continues to occupy a leading position among the methods of treatment of damage to the tubular bones of the extremities. This article presents a survey of 47 patients: 22 men and 25 women aged 25 to 60 years with fractures in the middle third of the radial shaft with displacement of bone fragments. The peculiarity of the external fixation device we used is that all transosseous elements are represented by 1.5 mm pins, inserted through both cortical layers of each bone, at levels from I and VIII. The pins are inserted simultaneously through both bones, thus excluding the rotational function of the forearm.The essence of the study is a comparative analysis of the blood system parameters in patients with diaphyseal injuries of the radial bone, operated by the transosseous osteosynthesis method using the external fixation device of pin configuration. Any damage to the body, (a fracture or related surgery), is accompanied with various changes in the system of hemodynamics and metabolism.The laboratory blood tests performed in the group of patients with damage to the radial shaft treated with transosseous osteosynthesis by external fixation device of pin configuration, revealed certain regularities in changing of blood parameters: increased number of platelets, increased level of fibrinogen and level of soluble fibrin complexes, which promotes the activation of the internal mechanism of blood clotting.
format article
author I. N. Kinash
M. E. Puseva
Ch. Z. Butaev
E. G. Ippolitova
author_facet I. N. Kinash
M. E. Puseva
Ch. Z. Butaev
E. G. Ippolitova
author_sort I. N. Kinash
title Dynamics of Blood Values in Patients with Radial Shaft Injury after Using Transosseous Osteosynthesis by external Fixation Pin Device
title_short Dynamics of Blood Values in Patients with Radial Shaft Injury after Using Transosseous Osteosynthesis by external Fixation Pin Device
title_full Dynamics of Blood Values in Patients with Radial Shaft Injury after Using Transosseous Osteosynthesis by external Fixation Pin Device
title_fullStr Dynamics of Blood Values in Patients with Radial Shaft Injury after Using Transosseous Osteosynthesis by external Fixation Pin Device
title_full_unstemmed Dynamics of Blood Values in Patients with Radial Shaft Injury after Using Transosseous Osteosynthesis by external Fixation Pin Device
title_sort dynamics of blood values in patients with radial shaft injury after using transosseous osteosynthesis by external fixation pin device
publisher Scientific Сentre for Family Health and Human Reproduction Problems
publishDate 2019
url https://doaj.org/article/3ea197e6f1294a4d8e8eda4ef0c30ecf
work_keys_str_mv AT inkinash dynamicsofbloodvaluesinpatientswithradialshaftinjuryafterusingtransosseousosteosynthesisbyexternalfixationpindevice
AT mepuseva dynamicsofbloodvaluesinpatientswithradialshaftinjuryafterusingtransosseousosteosynthesisbyexternalfixationpindevice
AT chzbutaev dynamicsofbloodvaluesinpatientswithradialshaftinjuryafterusingtransosseousosteosynthesisbyexternalfixationpindevice
AT egippolitova dynamicsofbloodvaluesinpatientswithradialshaftinjuryafterusingtransosseousosteosynthesisbyexternalfixationpindevice
_version_ 1718416936949252096