Removal characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant
The widespread implementation of municipal wastewater treatment and reuse must first ensure the safety of reused wastewater. The effluent of the municipal wastewater treatment plant contains a large amount of dissolved organic matter (DOM), which adversely affects the reuse of wastewater. In this st...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
IWA Publishing
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/3f7f7c8a30624ce7a941a15b0d0d0e5e |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:3f7f7c8a30624ce7a941a15b0d0d0e5e |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:3f7f7c8a30624ce7a941a15b0d0d0e5e2021-11-06T10:42:41ZRemoval characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant0273-12231996-973210.2166/wst.2020.589https://doaj.org/article/3f7f7c8a30624ce7a941a15b0d0d0e5e2021-02-01T00:00:00Zhttp://wst.iwaponline.com/content/83/3/689https://doaj.org/toc/0273-1223https://doaj.org/toc/1996-9732The widespread implementation of municipal wastewater treatment and reuse must first ensure the safety of reused wastewater. The effluent of the municipal wastewater treatment plant contains a large amount of dissolved organic matter (DOM), which adversely affects the reuse of wastewater. In this study, the ultrafiltration (UF) + reverse osmosis (RO) process was used to treat the secondary effluent from wastewater treatment plants. The relationship between the removal performance, membrane fouling of the UF + RO process, and DOM removal characteristics of influent were studied. The results show that DOM can be removed effectively by UF + RO process. The UF mainly removes DOM with a molecular weight greater than 10 kDa, while RO has a significant removal effect on low-molecular-weight DOM, which mainly causes UF and RO membrane fouling. The UF + RO process has a significant removal rate on fulvic acid, humic acid, tyrosine, and tryptophan, and the order is humic acid > fulvic acid > tyrosine > tryptophan. Fulvic acid contributed the most to the UF membrane fouling, while fulvic acid and protein-like proteins contributed mainly to the RO membrane fouling.Jianwei LiuMengfei ZhaoCui DuanPeng YueTinggang LiIWA Publishingarticlecombination processdommembrane foulinguf + rowastewater reclamationEnvironmental technology. Sanitary engineeringTD1-1066ENWater Science and Technology, Vol 83, Iss 3, Pp 689-700 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
combination process dom membrane fouling uf + ro wastewater reclamation Environmental technology. Sanitary engineering TD1-1066 |
spellingShingle |
combination process dom membrane fouling uf + ro wastewater reclamation Environmental technology. Sanitary engineering TD1-1066 Jianwei Liu Mengfei Zhao Cui Duan Peng Yue Tinggang Li Removal characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant |
description |
The widespread implementation of municipal wastewater treatment and reuse must first ensure the safety of reused wastewater. The effluent of the municipal wastewater treatment plant contains a large amount of dissolved organic matter (DOM), which adversely affects the reuse of wastewater. In this study, the ultrafiltration (UF) + reverse osmosis (RO) process was used to treat the secondary effluent from wastewater treatment plants. The relationship between the removal performance, membrane fouling of the UF + RO process, and DOM removal characteristics of influent were studied. The results show that DOM can be removed effectively by UF + RO process. The UF mainly removes DOM with a molecular weight greater than 10 kDa, while RO has a significant removal effect on low-molecular-weight DOM, which mainly causes UF and RO membrane fouling. The UF + RO process has a significant removal rate on fulvic acid, humic acid, tyrosine, and tryptophan, and the order is humic acid > fulvic acid > tyrosine > tryptophan. Fulvic acid contributed the most to the UF membrane fouling, while fulvic acid and protein-like proteins contributed mainly to the RO membrane fouling. |
format |
article |
author |
Jianwei Liu Mengfei Zhao Cui Duan Peng Yue Tinggang Li |
author_facet |
Jianwei Liu Mengfei Zhao Cui Duan Peng Yue Tinggang Li |
author_sort |
Jianwei Liu |
title |
Removal characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant |
title_short |
Removal characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant |
title_full |
Removal characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant |
title_fullStr |
Removal characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant |
title_full_unstemmed |
Removal characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant |
title_sort |
removal characteristics of dissolved organic matter and membrane fouling in ultrafiltration and reverse osmosis membrane combined processes treating the secondary effluent of wastewater treatment plant |
publisher |
IWA Publishing |
publishDate |
2021 |
url |
https://doaj.org/article/3f7f7c8a30624ce7a941a15b0d0d0e5e |
work_keys_str_mv |
AT jianweiliu removalcharacteristicsofdissolvedorganicmatterandmembranefoulinginultrafiltrationandreverseosmosismembranecombinedprocessestreatingthesecondaryeffluentofwastewatertreatmentplant AT mengfeizhao removalcharacteristicsofdissolvedorganicmatterandmembranefoulinginultrafiltrationandreverseosmosismembranecombinedprocessestreatingthesecondaryeffluentofwastewatertreatmentplant AT cuiduan removalcharacteristicsofdissolvedorganicmatterandmembranefoulinginultrafiltrationandreverseosmosismembranecombinedprocessestreatingthesecondaryeffluentofwastewatertreatmentplant AT pengyue removalcharacteristicsofdissolvedorganicmatterandmembranefoulinginultrafiltrationandreverseosmosismembranecombinedprocessestreatingthesecondaryeffluentofwastewatertreatmentplant AT tinggangli removalcharacteristicsofdissolvedorganicmatterandmembranefoulinginultrafiltrationandreverseosmosismembranecombinedprocessestreatingthesecondaryeffluentofwastewatertreatmentplant |
_version_ |
1718443789505265664 |