Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable

Stay cables are one of the vital components of a cable-stayed bridge. Due to their flexible nature, stay cables are vulnerable to external excitation and often vibrate with large amplitude under wind action which leads to the fatigue failure of the cables. To suppress such kind of large amplitude vi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Duy Thao Nguyen, Duy Hung Vo, Md. Naimul Haque
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
T
Acceso en línea:https://doaj.org/article/408f7a09889c4cef80e86a87316d2564
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:408f7a09889c4cef80e86a87316d2564
record_format dspace
spelling oai:doaj.org-article:408f7a09889c4cef80e86a87316d25642021-11-25T16:42:31ZTheoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable10.3390/app1122109852076-3417https://doaj.org/article/408f7a09889c4cef80e86a87316d25642021-11-01T00:00:00Zhttps://www.mdpi.com/2076-3417/11/22/10985https://doaj.org/toc/2076-3417Stay cables are one of the vital components of a cable-stayed bridge. Due to their flexible nature, stay cables are vulnerable to external excitation and often vibrate with large amplitude under wind action which leads to the fatigue failure of the cables. To suppress such kind of large amplitude vibration by improving the damping ratio of the cable various dampers such as magnetorheological damper, friction damper; oil damper; or high damping rubber (HDR) damper are utilized and gained popularity over time. This paper focuses on improving the damping ratio of stay cables using a combination of two HDR dampers. First, the theoretical model is formulated considering cable bending stiffness to evaluate the damping effect of cable-HDR dampers system. Then, the impact of various design parameters of HDR dampers on cable damping considering the cable stiffness is performed. The comparative analysis of results shows that the considered parameters such as loss factor, spring factor, and installation location of dampers have much effect on the stay cables damping ratio. Finally, the optimal parameters of the two HDR dampers are proposed for damper design.Duy Thao NguyenDuy Hung VoMd. Naimul HaqueMDPI AGarticletwo HDR dampersstay cabledamping ratiospring factorloss factorcable bending stiffnessTechnologyTEngineering (General). Civil engineering (General)TA1-2040Biology (General)QH301-705.5PhysicsQC1-999ChemistryQD1-999ENApplied Sciences, Vol 11, Iss 10985, p 10985 (2021)
institution DOAJ
collection DOAJ
language EN
topic two HDR dampers
stay cable
damping ratio
spring factor
loss factor
cable bending stiffness
Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
Biology (General)
QH301-705.5
Physics
QC1-999
Chemistry
QD1-999
spellingShingle two HDR dampers
stay cable
damping ratio
spring factor
loss factor
cable bending stiffness
Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
Biology (General)
QH301-705.5
Physics
QC1-999
Chemistry
QD1-999
Duy Thao Nguyen
Duy Hung Vo
Md. Naimul Haque
Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable
description Stay cables are one of the vital components of a cable-stayed bridge. Due to their flexible nature, stay cables are vulnerable to external excitation and often vibrate with large amplitude under wind action which leads to the fatigue failure of the cables. To suppress such kind of large amplitude vibration by improving the damping ratio of the cable various dampers such as magnetorheological damper, friction damper; oil damper; or high damping rubber (HDR) damper are utilized and gained popularity over time. This paper focuses on improving the damping ratio of stay cables using a combination of two HDR dampers. First, the theoretical model is formulated considering cable bending stiffness to evaluate the damping effect of cable-HDR dampers system. Then, the impact of various design parameters of HDR dampers on cable damping considering the cable stiffness is performed. The comparative analysis of results shows that the considered parameters such as loss factor, spring factor, and installation location of dampers have much effect on the stay cables damping ratio. Finally, the optimal parameters of the two HDR dampers are proposed for damper design.
format article
author Duy Thao Nguyen
Duy Hung Vo
Md. Naimul Haque
author_facet Duy Thao Nguyen
Duy Hung Vo
Md. Naimul Haque
author_sort Duy Thao Nguyen
title Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable
title_short Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable
title_full Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable
title_fullStr Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable
title_full_unstemmed Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable
title_sort theoretical investigation on the impact of two hdr dampers on first modal damping ratio of stay cable
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/408f7a09889c4cef80e86a87316d2564
work_keys_str_mv AT duythaonguyen theoreticalinvestigationontheimpactoftwohdrdampersonfirstmodaldampingratioofstaycable
AT duyhungvo theoreticalinvestigationontheimpactoftwohdrdampersonfirstmodaldampingratioofstaycable
AT mdnaimulhaque theoreticalinvestigationontheimpactoftwohdrdampersonfirstmodaldampingratioofstaycable
_version_ 1718413013780791296