Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable
Stay cables are one of the vital components of a cable-stayed bridge. Due to their flexible nature, stay cables are vulnerable to external excitation and often vibrate with large amplitude under wind action which leads to the fatigue failure of the cables. To suppress such kind of large amplitude vi...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/408f7a09889c4cef80e86a87316d2564 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:408f7a09889c4cef80e86a87316d2564 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:408f7a09889c4cef80e86a87316d25642021-11-25T16:42:31ZTheoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable10.3390/app1122109852076-3417https://doaj.org/article/408f7a09889c4cef80e86a87316d25642021-11-01T00:00:00Zhttps://www.mdpi.com/2076-3417/11/22/10985https://doaj.org/toc/2076-3417Stay cables are one of the vital components of a cable-stayed bridge. Due to their flexible nature, stay cables are vulnerable to external excitation and often vibrate with large amplitude under wind action which leads to the fatigue failure of the cables. To suppress such kind of large amplitude vibration by improving the damping ratio of the cable various dampers such as magnetorheological damper, friction damper; oil damper; or high damping rubber (HDR) damper are utilized and gained popularity over time. This paper focuses on improving the damping ratio of stay cables using a combination of two HDR dampers. First, the theoretical model is formulated considering cable bending stiffness to evaluate the damping effect of cable-HDR dampers system. Then, the impact of various design parameters of HDR dampers on cable damping considering the cable stiffness is performed. The comparative analysis of results shows that the considered parameters such as loss factor, spring factor, and installation location of dampers have much effect on the stay cables damping ratio. Finally, the optimal parameters of the two HDR dampers are proposed for damper design.Duy Thao NguyenDuy Hung VoMd. Naimul HaqueMDPI AGarticletwo HDR dampersstay cabledamping ratiospring factorloss factorcable bending stiffnessTechnologyTEngineering (General). Civil engineering (General)TA1-2040Biology (General)QH301-705.5PhysicsQC1-999ChemistryQD1-999ENApplied Sciences, Vol 11, Iss 10985, p 10985 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
two HDR dampers stay cable damping ratio spring factor loss factor cable bending stiffness Technology T Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 |
spellingShingle |
two HDR dampers stay cable damping ratio spring factor loss factor cable bending stiffness Technology T Engineering (General). Civil engineering (General) TA1-2040 Biology (General) QH301-705.5 Physics QC1-999 Chemistry QD1-999 Duy Thao Nguyen Duy Hung Vo Md. Naimul Haque Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable |
description |
Stay cables are one of the vital components of a cable-stayed bridge. Due to their flexible nature, stay cables are vulnerable to external excitation and often vibrate with large amplitude under wind action which leads to the fatigue failure of the cables. To suppress such kind of large amplitude vibration by improving the damping ratio of the cable various dampers such as magnetorheological damper, friction damper; oil damper; or high damping rubber (HDR) damper are utilized and gained popularity over time. This paper focuses on improving the damping ratio of stay cables using a combination of two HDR dampers. First, the theoretical model is formulated considering cable bending stiffness to evaluate the damping effect of cable-HDR dampers system. Then, the impact of various design parameters of HDR dampers on cable damping considering the cable stiffness is performed. The comparative analysis of results shows that the considered parameters such as loss factor, spring factor, and installation location of dampers have much effect on the stay cables damping ratio. Finally, the optimal parameters of the two HDR dampers are proposed for damper design. |
format |
article |
author |
Duy Thao Nguyen Duy Hung Vo Md. Naimul Haque |
author_facet |
Duy Thao Nguyen Duy Hung Vo Md. Naimul Haque |
author_sort |
Duy Thao Nguyen |
title |
Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable |
title_short |
Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable |
title_full |
Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable |
title_fullStr |
Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable |
title_full_unstemmed |
Theoretical Investigation on the Impact of Two HDR Dampers on First Modal Damping Ratio of Stay Cable |
title_sort |
theoretical investigation on the impact of two hdr dampers on first modal damping ratio of stay cable |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/408f7a09889c4cef80e86a87316d2564 |
work_keys_str_mv |
AT duythaonguyen theoreticalinvestigationontheimpactoftwohdrdampersonfirstmodaldampingratioofstaycable AT duyhungvo theoreticalinvestigationontheimpactoftwohdrdampersonfirstmodaldampingratioofstaycable AT mdnaimulhaque theoreticalinvestigationontheimpactoftwohdrdampersonfirstmodaldampingratioofstaycable |
_version_ |
1718413013780791296 |