Performance of transient elastography for the staging of liver fibrosis in patients with chronic hepatitis B: a meta-analysis.

<h4>Background</h4>Transient elastography (TE), a non-invasive tool that measures liver stiffness, has been evaluated in meta-analyses for effectiveness in assessing liver fibrosis in European populations with chronic hepatitis C (CHC). However, these data cannot be extrapolated to popul...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Young Eun Chon, Eun Hee Choi, Ki Jun Song, Jun Yong Park, Do Young Kim, Kwang-Hyub Han, Chae Yoon Chon, Sang Hoon Ahn, Seung Up Kim
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2012
Materias:
R
Q
Acceso en línea:https://doaj.org/article/42eddf83a650488c9ee117125e2aabcc
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:<h4>Background</h4>Transient elastography (TE), a non-invasive tool that measures liver stiffness, has been evaluated in meta-analyses for effectiveness in assessing liver fibrosis in European populations with chronic hepatitis C (CHC). However, these data cannot be extrapolated to populations in Asian countries, where chronic hepatitis B (CHB) is more prevalent. In this study, we performed a meta-analysis to assess the overall performance of TE for assessing liver fibrosis in patients with CHB.<h4>Methods</h4>Studies from the literature and international conference abstracts which enrolled only patients with CHB or performed a subgroup analysis of such patients were enrolled. Combined effects were calculated using area under the receiver operating characteristic curves (AUROC) and diagnostic accuracy values of each study.<h4>Result</h4>A total of 18 studies comprising 2,772 patients were analyzed. The mean AUROCs for the diagnosis of significant fibrosis (F2), severe fibrosis (F3), and cirrhosis (F4) were 0.859 (95% confidence interval [CI], 0.857-0.860), 0.887 (95% CI, 0.886-0.887), and 0.929 (95% CI, 0.928-0.929), respectively. The estimated cutoff for F2 was 7.9 (range, 6.1-11.8) kPa, with a sensitivity of 74.3% and specificity of 78.3%. For F3, the cutoff value was determined to be 8.8 (range, 8.1-9.7) kPa, with a sensitivity of 74.0% and specificity of 63.8%. The cutoff value for F4 was 11.7 (range, 7.3-17.5) kPa, with a sensitivity of 84.6% and specificity of 81.5%.<h4>Conclusion</h4>TE can be performed with good diagnostic accuracy for quantifying liver fibrosis in patients with CHB.