Load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy

Abstract Pedicle subtraction osteotomy (PSO) is an invasive surgical technique allowing the restoration of a well-balanced sagittal profile, however, the risks of pseudarthrosis and instrumentation breakage are still high. Literature studied primary stability and posterior instrumentation loads, neg...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Luigi La Barbera, Hans-Joachim Wilke, Maria Luisa Ruspi, Marco Palanca, Christian Liebsch, Andrea Luca, Marco Brayda-Bruno, Fabio Galbusera, Luca Cristofolini
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/431f7dffc161498dbf7468ca444e50f0
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:431f7dffc161498dbf7468ca444e50f0
record_format dspace
spelling oai:doaj.org-article:431f7dffc161498dbf7468ca444e50f02021-12-02T14:11:28ZLoad-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy10.1038/s41598-021-83251-82045-2322https://doaj.org/article/431f7dffc161498dbf7468ca444e50f02021-02-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-83251-8https://doaj.org/toc/2045-2322Abstract Pedicle subtraction osteotomy (PSO) is an invasive surgical technique allowing the restoration of a well-balanced sagittal profile, however, the risks of pseudarthrosis and instrumentation breakage are still high. Literature studied primary stability and posterior instrumentation loads, neglecting the load shared by the anterior column, which is fundamental to promote fusion early after surgery. The study aimed at quantifying the load-sharing occurring after PSO procedure across the ventral spinal structures and the posterior instrumentation, as affected by simple bilateral fixation alone, with interbody cages adjacent to PSO level and supplementary accessory rods. Lumbar spine segments were loaded in vitro under flexion–extension, lateral bending, and torsion using an established spine tester. Digital image correlation (DIC) and strain-gauge (SG) analyses measured, respectively, the full-field strain distribution on the ventral surface of the spine and the local strain on posterior primary rods. Ventral strains considerably decreased following PSO and instrumentation, confirming the effectiveness of posterior load-sharing. Supplemental accessory rods considerably reduced the posterior rod strains only with interbody cages, but the ventral strains were unaffected: this indicates that the load transfer across the osteotomy could be promoted, thus explaining the higher fusion rate with decreased rod fracture risk reported in clinical literature.Luigi La BarberaHans-Joachim WilkeMaria Luisa RuspiMarco PalancaChristian LiebschAndrea LucaMarco Brayda-BrunoFabio GalbuseraLuca CristofoliniNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-13 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Luigi La Barbera
Hans-Joachim Wilke
Maria Luisa Ruspi
Marco Palanca
Christian Liebsch
Andrea Luca
Marco Brayda-Bruno
Fabio Galbusera
Luca Cristofolini
Load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy
description Abstract Pedicle subtraction osteotomy (PSO) is an invasive surgical technique allowing the restoration of a well-balanced sagittal profile, however, the risks of pseudarthrosis and instrumentation breakage are still high. Literature studied primary stability and posterior instrumentation loads, neglecting the load shared by the anterior column, which is fundamental to promote fusion early after surgery. The study aimed at quantifying the load-sharing occurring after PSO procedure across the ventral spinal structures and the posterior instrumentation, as affected by simple bilateral fixation alone, with interbody cages adjacent to PSO level and supplementary accessory rods. Lumbar spine segments were loaded in vitro under flexion–extension, lateral bending, and torsion using an established spine tester. Digital image correlation (DIC) and strain-gauge (SG) analyses measured, respectively, the full-field strain distribution on the ventral surface of the spine and the local strain on posterior primary rods. Ventral strains considerably decreased following PSO and instrumentation, confirming the effectiveness of posterior load-sharing. Supplemental accessory rods considerably reduced the posterior rod strains only with interbody cages, but the ventral strains were unaffected: this indicates that the load transfer across the osteotomy could be promoted, thus explaining the higher fusion rate with decreased rod fracture risk reported in clinical literature.
format article
author Luigi La Barbera
Hans-Joachim Wilke
Maria Luisa Ruspi
Marco Palanca
Christian Liebsch
Andrea Luca
Marco Brayda-Bruno
Fabio Galbusera
Luca Cristofolini
author_facet Luigi La Barbera
Hans-Joachim Wilke
Maria Luisa Ruspi
Marco Palanca
Christian Liebsch
Andrea Luca
Marco Brayda-Bruno
Fabio Galbusera
Luca Cristofolini
author_sort Luigi La Barbera
title Load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy
title_short Load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy
title_full Load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy
title_fullStr Load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy
title_full_unstemmed Load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy
title_sort load-sharing biomechanics of lumbar fixation and fusion with pedicle subtraction osteotomy
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/431f7dffc161498dbf7468ca444e50f0
work_keys_str_mv AT luigilabarbera loadsharingbiomechanicsoflumbarfixationandfusionwithpediclesubtractionosteotomy
AT hansjoachimwilke loadsharingbiomechanicsoflumbarfixationandfusionwithpediclesubtractionosteotomy
AT marialuisaruspi loadsharingbiomechanicsoflumbarfixationandfusionwithpediclesubtractionosteotomy
AT marcopalanca loadsharingbiomechanicsoflumbarfixationandfusionwithpediclesubtractionosteotomy
AT christianliebsch loadsharingbiomechanicsoflumbarfixationandfusionwithpediclesubtractionosteotomy
AT andrealuca loadsharingbiomechanicsoflumbarfixationandfusionwithpediclesubtractionosteotomy
AT marcobraydabruno loadsharingbiomechanicsoflumbarfixationandfusionwithpediclesubtractionosteotomy
AT fabiogalbusera loadsharingbiomechanicsoflumbarfixationandfusionwithpediclesubtractionosteotomy
AT lucacristofolini loadsharingbiomechanicsoflumbarfixationandfusionwithpediclesubtractionosteotomy
_version_ 1718391837939466240