Coefficient of variation as an image-intensity metric for cytoskeleton bundling

Abstract The evaluation of cytoskeletal bundling is a fundamental experimental method in the field of cell biology. Although the skewness of the pixel intensity distribution derived from fluorescently-labeled cytoskeletons has been widely used as a metric to evaluate the degree of bundling in digita...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Takumi Higaki, Kae Akita, Kaoru Katoh
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2020
Materias:
R
Q
Acceso en línea:https://doaj.org/article/439993b9ae7945f691d1794bfb1124c7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:439993b9ae7945f691d1794bfb1124c7
record_format dspace
spelling oai:doaj.org-article:439993b9ae7945f691d1794bfb1124c72021-12-02T13:57:01ZCoefficient of variation as an image-intensity metric for cytoskeleton bundling10.1038/s41598-020-79136-x2045-2322https://doaj.org/article/439993b9ae7945f691d1794bfb1124c72020-12-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-79136-xhttps://doaj.org/toc/2045-2322Abstract The evaluation of cytoskeletal bundling is a fundamental experimental method in the field of cell biology. Although the skewness of the pixel intensity distribution derived from fluorescently-labeled cytoskeletons has been widely used as a metric to evaluate the degree of bundling in digital microscopy images, its versatility has not been fully validated. Here, we applied the coefficient of variation (CV) of intensity values as an alternative metric, and compared its performance with skewness. In synthetic images representing extremely bundled conditions, the CV successfully detected degrees of bundling that could not be distinguished by skewness. On actual microscopy images, CV was better than skewness, especially on variable-angle epifluorescence microscopic images or stimulated emission depletion and confocal microscopy images of very small areas of around 1 μm2. When blur or noise was added to synthetic images, CV was found to be robust to blur but deleteriously affected by noise, whereas skewness was robust to noise but deleteriously affected by blur. For confocal images, CV and skewness showed similar sensitivity to noise, possibly because optical blurring is often present in microscopy images. Therefore, in practical use with actual microscopy images, CV may be more appropriate than skewness, unless the image is extremely noisy.Takumi HigakiKae AkitaKaoru KatohNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 10, Iss 1, Pp 1-13 (2020)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Takumi Higaki
Kae Akita
Kaoru Katoh
Coefficient of variation as an image-intensity metric for cytoskeleton bundling
description Abstract The evaluation of cytoskeletal bundling is a fundamental experimental method in the field of cell biology. Although the skewness of the pixel intensity distribution derived from fluorescently-labeled cytoskeletons has been widely used as a metric to evaluate the degree of bundling in digital microscopy images, its versatility has not been fully validated. Here, we applied the coefficient of variation (CV) of intensity values as an alternative metric, and compared its performance with skewness. In synthetic images representing extremely bundled conditions, the CV successfully detected degrees of bundling that could not be distinguished by skewness. On actual microscopy images, CV was better than skewness, especially on variable-angle epifluorescence microscopic images or stimulated emission depletion and confocal microscopy images of very small areas of around 1 μm2. When blur or noise was added to synthetic images, CV was found to be robust to blur but deleteriously affected by noise, whereas skewness was robust to noise but deleteriously affected by blur. For confocal images, CV and skewness showed similar sensitivity to noise, possibly because optical blurring is often present in microscopy images. Therefore, in practical use with actual microscopy images, CV may be more appropriate than skewness, unless the image is extremely noisy.
format article
author Takumi Higaki
Kae Akita
Kaoru Katoh
author_facet Takumi Higaki
Kae Akita
Kaoru Katoh
author_sort Takumi Higaki
title Coefficient of variation as an image-intensity metric for cytoskeleton bundling
title_short Coefficient of variation as an image-intensity metric for cytoskeleton bundling
title_full Coefficient of variation as an image-intensity metric for cytoskeleton bundling
title_fullStr Coefficient of variation as an image-intensity metric for cytoskeleton bundling
title_full_unstemmed Coefficient of variation as an image-intensity metric for cytoskeleton bundling
title_sort coefficient of variation as an image-intensity metric for cytoskeleton bundling
publisher Nature Portfolio
publishDate 2020
url https://doaj.org/article/439993b9ae7945f691d1794bfb1124c7
work_keys_str_mv AT takumihigaki coefficientofvariationasanimageintensitymetricforcytoskeletonbundling
AT kaeakita coefficientofvariationasanimageintensitymetricforcytoskeletonbundling
AT kaorukatoh coefficientofvariationasanimageintensitymetricforcytoskeletonbundling
_version_ 1718392317509894144