AN ADAPTIVE HARMONIC COMPENSATION STRATEGY FOR THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON DOUBLE SECOND-ORDER GENERALIZED INTEGRATOR WITH PREFILTER

Abstract. This study presents a straightforward adaptive prefiltering algorithm based on a double second-order generalized integrator with prefilter to solve one of the power quality issues, this algorithm is in charge of the determination of the reference harmonic currents in the control of three-p...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: S. Kalkoul, H. Benalla, K. Nabti, R. Abdellatif
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2020
Materias:
Acceso en línea:https://doaj.org/article/43be526457764b0eb80acb448e1162de
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:43be526457764b0eb80acb448e1162de
record_format dspace
spelling oai:doaj.org-article:43be526457764b0eb80acb448e1162de2021-12-02T16:30:17ZAN ADAPTIVE HARMONIC COMPENSATION STRATEGY FOR THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON DOUBLE SECOND-ORDER GENERALIZED INTEGRATOR WITH PREFILTER10.20998/2074-272X.2020.3.092074-272X2309-3404https://doaj.org/article/43be526457764b0eb80acb448e1162de2020-06-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2020.3.09/206290https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Abstract. This study presents a straightforward adaptive prefiltering algorithm based on a double second-order generalized integrator with prefilter to solve one of the power quality issues, this algorithm is in charge of the determination of the reference harmonic currents in the control of three-phase shunt active power filter which presents an effective way to enhance the grid current quality. The proposed algorithm is used twice, to extract the harmonic currents produced by the non-linear loads and be an interesting part in the estimation of the frequency and amplitude of the fundamental voltage in various anomalies which can be noticed on the grid voltage. The performance, precision, and robustness of the proposed method are evidenced under balanced, unbalanced, and distorted grid voltage in the simulation and experimental results obtained by the implementation of the shunt active power filter on MATLAB-Simulink environment and the dSPACE 1104 platform respectively. S. KalkoulH. BenallaK. NabtiR. AbdellatifNational Technical University "Kharkiv Polytechnic Institute"articlesogi-wpfsapfharmonic currentspower qualitydsogi-pll-wpfElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 3, Pp 58-64 (2020)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic sogi-wpf
sapf
harmonic currents
power quality
dsogi-pll-wpf
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle sogi-wpf
sapf
harmonic currents
power quality
dsogi-pll-wpf
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
S. Kalkoul
H. Benalla
K. Nabti
R. Abdellatif
AN ADAPTIVE HARMONIC COMPENSATION STRATEGY FOR THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON DOUBLE SECOND-ORDER GENERALIZED INTEGRATOR WITH PREFILTER
description Abstract. This study presents a straightforward adaptive prefiltering algorithm based on a double second-order generalized integrator with prefilter to solve one of the power quality issues, this algorithm is in charge of the determination of the reference harmonic currents in the control of three-phase shunt active power filter which presents an effective way to enhance the grid current quality. The proposed algorithm is used twice, to extract the harmonic currents produced by the non-linear loads and be an interesting part in the estimation of the frequency and amplitude of the fundamental voltage in various anomalies which can be noticed on the grid voltage. The performance, precision, and robustness of the proposed method are evidenced under balanced, unbalanced, and distorted grid voltage in the simulation and experimental results obtained by the implementation of the shunt active power filter on MATLAB-Simulink environment and the dSPACE 1104 platform respectively.
format article
author S. Kalkoul
H. Benalla
K. Nabti
R. Abdellatif
author_facet S. Kalkoul
H. Benalla
K. Nabti
R. Abdellatif
author_sort S. Kalkoul
title AN ADAPTIVE HARMONIC COMPENSATION STRATEGY FOR THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON DOUBLE SECOND-ORDER GENERALIZED INTEGRATOR WITH PREFILTER
title_short AN ADAPTIVE HARMONIC COMPENSATION STRATEGY FOR THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON DOUBLE SECOND-ORDER GENERALIZED INTEGRATOR WITH PREFILTER
title_full AN ADAPTIVE HARMONIC COMPENSATION STRATEGY FOR THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON DOUBLE SECOND-ORDER GENERALIZED INTEGRATOR WITH PREFILTER
title_fullStr AN ADAPTIVE HARMONIC COMPENSATION STRATEGY FOR THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON DOUBLE SECOND-ORDER GENERALIZED INTEGRATOR WITH PREFILTER
title_full_unstemmed AN ADAPTIVE HARMONIC COMPENSATION STRATEGY FOR THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON DOUBLE SECOND-ORDER GENERALIZED INTEGRATOR WITH PREFILTER
title_sort adaptive harmonic compensation strategy for three-phase shunt active power filter based on double second-order generalized integrator with prefilter
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2020
url https://doaj.org/article/43be526457764b0eb80acb448e1162de
work_keys_str_mv AT skalkoul anadaptiveharmoniccompensationstrategyforthreephaseshuntactivepowerfilterbasedondoublesecondordergeneralizedintegratorwithprefilter
AT hbenalla anadaptiveharmoniccompensationstrategyforthreephaseshuntactivepowerfilterbasedondoublesecondordergeneralizedintegratorwithprefilter
AT knabti anadaptiveharmoniccompensationstrategyforthreephaseshuntactivepowerfilterbasedondoublesecondordergeneralizedintegratorwithprefilter
AT rabdellatif anadaptiveharmoniccompensationstrategyforthreephaseshuntactivepowerfilterbasedondoublesecondordergeneralizedintegratorwithprefilter
AT skalkoul adaptiveharmoniccompensationstrategyforthreephaseshuntactivepowerfilterbasedondoublesecondordergeneralizedintegratorwithprefilter
AT hbenalla adaptiveharmoniccompensationstrategyforthreephaseshuntactivepowerfilterbasedondoublesecondordergeneralizedintegratorwithprefilter
AT knabti adaptiveharmoniccompensationstrategyforthreephaseshuntactivepowerfilterbasedondoublesecondordergeneralizedintegratorwithprefilter
AT rabdellatif adaptiveharmoniccompensationstrategyforthreephaseshuntactivepowerfilterbasedondoublesecondordergeneralizedintegratorwithprefilter
_version_ 1718383926379020288