A Novel Approach for the Design of Fast-Settling Amplifiers for Biosignal Detection

The most common method used to pick up biomedical signals is through metallic electrodes coupled to the input of high-gain, low-noise amplifiers. Unfortunately, electrodes, amongst other effects, introduce an undesired contact resistance and a contact potential. The contact potential needs to be rej...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Eduardo Alonso Rivas, Graziella Scandurra, Carmine Ciofi, Carlos Rodríguez-Morcillo García , Romano Giannetti
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/43d0de15d2c445b69bc6907aa792d0bd
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:43d0de15d2c445b69bc6907aa792d0bd
record_format dspace
spelling oai:doaj.org-article:43d0de15d2c445b69bc6907aa792d0bd2021-11-11T15:38:45ZA Novel Approach for the Design of Fast-Settling Amplifiers for Biosignal Detection10.3390/electronics102126312079-9292https://doaj.org/article/43d0de15d2c445b69bc6907aa792d0bd2021-10-01T00:00:00Zhttps://www.mdpi.com/2079-9292/10/21/2631https://doaj.org/toc/2079-9292The most common method used to pick up biomedical signals is through metallic electrodes coupled to the input of high-gain, low-noise amplifiers. Unfortunately, electrodes, amongst other effects, introduce an undesired contact resistance and a contact potential. The contact potential needs to be rejected since it would otherwise cause the saturation of the input stage of the amplifiers, and this is almost always obtained by inserting a simple RC high-pass filter in the input signal path. The contact resistance needs to be estimated to ensure that it does not impair correct measurements. Methods exist for estimating the contact resistance by dynamically modifying the input network configuration, but because of the presence of the input RC filter, long transients are induced any time a switch occurs between different input configurations, so that the measurement time may become unacceptably long. In this paper, we propose a new topology for a DC removal network at the input of the differential signal amplifier that results in an AC filter whose time constant can be continuously changed by means of a control voltage. As such, we can speed up the recovery from transients by setting very short time constants (during the input resistance estimation process) while maintaining the ability to obtain very low cut-in frequencies by setting a much larger time constant during actual measurements. A prototype of the system was built and tested in order to demonstrate the advantage of the approach we propose in terms of reduced measurement time.Eduardo Alonso RivasGraziella ScandurraCarmine CiofiCarlos Rodríguez-Morcillo García Romano GiannettiMDPI AGarticledifferential amplifierDC removalbiological signalselectrode potentialElectronicsTK7800-8360ENElectronics, Vol 10, Iss 2631, p 2631 (2021)
institution DOAJ
collection DOAJ
language EN
topic differential amplifier
DC removal
biological signals
electrode potential
Electronics
TK7800-8360
spellingShingle differential amplifier
DC removal
biological signals
electrode potential
Electronics
TK7800-8360
Eduardo Alonso Rivas
Graziella Scandurra
Carmine Ciofi
Carlos Rodríguez-Morcillo García 
Romano Giannetti
A Novel Approach for the Design of Fast-Settling Amplifiers for Biosignal Detection
description The most common method used to pick up biomedical signals is through metallic electrodes coupled to the input of high-gain, low-noise amplifiers. Unfortunately, electrodes, amongst other effects, introduce an undesired contact resistance and a contact potential. The contact potential needs to be rejected since it would otherwise cause the saturation of the input stage of the amplifiers, and this is almost always obtained by inserting a simple RC high-pass filter in the input signal path. The contact resistance needs to be estimated to ensure that it does not impair correct measurements. Methods exist for estimating the contact resistance by dynamically modifying the input network configuration, but because of the presence of the input RC filter, long transients are induced any time a switch occurs between different input configurations, so that the measurement time may become unacceptably long. In this paper, we propose a new topology for a DC removal network at the input of the differential signal amplifier that results in an AC filter whose time constant can be continuously changed by means of a control voltage. As such, we can speed up the recovery from transients by setting very short time constants (during the input resistance estimation process) while maintaining the ability to obtain very low cut-in frequencies by setting a much larger time constant during actual measurements. A prototype of the system was built and tested in order to demonstrate the advantage of the approach we propose in terms of reduced measurement time.
format article
author Eduardo Alonso Rivas
Graziella Scandurra
Carmine Ciofi
Carlos Rodríguez-Morcillo García 
Romano Giannetti
author_facet Eduardo Alonso Rivas
Graziella Scandurra
Carmine Ciofi
Carlos Rodríguez-Morcillo García 
Romano Giannetti
author_sort Eduardo Alonso Rivas
title A Novel Approach for the Design of Fast-Settling Amplifiers for Biosignal Detection
title_short A Novel Approach for the Design of Fast-Settling Amplifiers for Biosignal Detection
title_full A Novel Approach for the Design of Fast-Settling Amplifiers for Biosignal Detection
title_fullStr A Novel Approach for the Design of Fast-Settling Amplifiers for Biosignal Detection
title_full_unstemmed A Novel Approach for the Design of Fast-Settling Amplifiers for Biosignal Detection
title_sort novel approach for the design of fast-settling amplifiers for biosignal detection
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/43d0de15d2c445b69bc6907aa792d0bd
work_keys_str_mv AT eduardoalonsorivas anovelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
AT graziellascandurra anovelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
AT carmineciofi anovelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
AT carlosrodriguezmorcillogarcia anovelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
AT romanogiannetti anovelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
AT eduardoalonsorivas novelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
AT graziellascandurra novelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
AT carmineciofi novelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
AT carlosrodriguezmorcillogarcia novelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
AT romanogiannetti novelapproachforthedesignoffastsettlingamplifiersforbiosignaldetection
_version_ 1718434726823329792