EXPERIMENTAL STUDY OF FERROMAGNETIC CORE PARAMETERS INFLUENCE ON ELECTROMECHANICAL CHARACTERISTICS OF A LINEAR INDUCTION-DYNAMIC CONVERTER

Experimental studies of ferromagnetic core parameters action on electromechanical characteristics of a linear induction-dynamic converter are conducted. An experimental installation is designed and built to determine the converter electromechanical parameters during its operation. A ferromagnetic co...

Full description

Saved in:
Bibliographic Details
Main Authors: V.F. Bolyukh, S.V. Oleksenko, I.S. Schukin
Format: article
Language:EN
RU
UK
Published: National Technical University "Kharkiv Polytechnic Institute" 2014
Subjects:
Online Access:https://doaj.org/article/43dd5bd967b54d719355da75a04f32d3
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Experimental studies of ferromagnetic core parameters action on electromechanical characteristics of a linear induction-dynamic converter are conducted. An experimental installation is designed and built to determine the converter electromechanical parameters during its operation. A ferromagnetic core with four radial slots made allows regulating the height of the base and the outer shell. The core geometric parameters providing the highest speed of the armature are specified. Under certain parameters, the ferromagnetic core increases the converter efficiency up to 50%. The experimental results confirm the analytical studies within 6 % error.