EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability
Jessica E Chan, Peter A Netland Department of Ophthalmology, University of Virginia School of Medicine, Charlottesville, VA, USA Abstract: Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, co...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://doaj.org/article/43ded5426e1943e887f5022000fb42f2 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:43ded5426e1943e887f5022000fb42f2 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:43ded5426e1943e887f5022000fb42f22021-12-02T01:41:40ZEX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability1179-1470https://doaj.org/article/43ded5426e1943e887f5022000fb42f22015-09-01T00:00:00Zhttps://www.dovepress.com/ex-press-glaucoma-filtration-device-efficacy-safety-and-predictability-peer-reviewed-article-MDERhttps://doaj.org/toc/1179-1470Jessica E Chan, Peter A Netland Department of Ophthalmology, University of Virginia School of Medicine, Charlottesville, VA, USA Abstract: Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. Keywords: surgery, trabeculectomy, mitomycin C, glaucoma drainage implantChan JENetlPADove Medical PressarticleMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol 2015, Iss default, Pp 381-388 (2015) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medical technology R855-855.5 |
spellingShingle |
Medical technology R855-855.5 Chan JE Netl PA EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
description |
Jessica E Chan, Peter A Netland Department of Ophthalmology, University of Virginia School of Medicine, Charlottesville, VA, USA Abstract: Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. Keywords: surgery, trabeculectomy, mitomycin C, glaucoma drainage implant |
format |
article |
author |
Chan JE Netl PA |
author_facet |
Chan JE Netl PA |
author_sort |
Chan JE |
title |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_short |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_full |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_fullStr |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_full_unstemmed |
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_sort |
ex-press glaucoma filtration device: efficacy, safety, and predictability |
publisher |
Dove Medical Press |
publishDate |
2015 |
url |
https://doaj.org/article/43ded5426e1943e887f5022000fb42f2 |
work_keys_str_mv |
AT chanje expressglaucomafiltrationdeviceefficacysafetyandpredictability AT netl expressglaucomafiltrationdeviceefficacysafetyandpredictability AT pa expressglaucomafiltrationdeviceefficacysafetyandpredictability |
_version_ |
1718402890673946624 |