The reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data

Abstract This study aimed to evaluate (1) the overall reasons for first revision in CoC THAs; (2) whether the reasons for revision differ between third-generation and fourth-generation CoC THAs; and (3) the specific factors associated with bearing-related problems as the reason for revision. We retr...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Sang-Min Kim, Kee Hyung Rhyu, Jeong Joon Yoo, Seung-Jae Lim, Je Hyun Yoo, Suc Hyun Kweon, Kyung-Jae Lee, Seung-Beom Han
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/43ea694be14d41c9a50dd9ca20e78e9a
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:43ea694be14d41c9a50dd9ca20e78e9a
record_format dspace
spelling oai:doaj.org-article:43ea694be14d41c9a50dd9ca20e78e9a2021-12-02T13:19:22ZThe reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data10.1038/s41598-021-85193-72045-2322https://doaj.org/article/43ea694be14d41c9a50dd9ca20e78e9a2021-03-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-85193-7https://doaj.org/toc/2045-2322Abstract This study aimed to evaluate (1) the overall reasons for first revision in CoC THAs; (2) whether the reasons for revision differ between third-generation and fourth-generation CoC THAs; and (3) the specific factors associated with bearing-related problems as the reason for revision. We retrospectively reviewed 2045 patients (2194 hips) who underwent first revision THA between 2004 and 2013, among which 146 hips with CoC bearings underwent revision. There were 92 hips with third-generation ceramic bearings and 54 hips with fourth-generation ceramic bearings. The major reasons for CoC THA revisions were ceramic fracture and loosening of the cup or stem. When ceramic fracture, squeaking, incorrect ceramic insertion, and unexplained pain were defined as directly related or potentially related to ceramic use, 28.8% (42/146) of CoC revisions were associated with bearing-related problems. Among the third-generation ceramic bearings, revision was performed in 41.3% (38/92) of cases owing to bearing-related problems whereas revisions were performed for only 7.4% (4/54) of cases with fourth-generation ceramic bearings owing to bearing-related problems (p < 0.001). Younger age, lower American Society of Anesthesiologists (ASA) grade, and preoperative diagnosis of osteonecrosis were factors related to CoC THA revisions due to bearing-related problems.Sang-Min KimKee Hyung RhyuJeong Joon YooSeung-Jae LimJe Hyun YooSuc Hyun KweonKyung-Jae LeeSeung-Beom HanNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Sang-Min Kim
Kee Hyung Rhyu
Jeong Joon Yoo
Seung-Jae Lim
Je Hyun Yoo
Suc Hyun Kweon
Kyung-Jae Lee
Seung-Beom Han
The reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data
description Abstract This study aimed to evaluate (1) the overall reasons for first revision in CoC THAs; (2) whether the reasons for revision differ between third-generation and fourth-generation CoC THAs; and (3) the specific factors associated with bearing-related problems as the reason for revision. We retrospectively reviewed 2045 patients (2194 hips) who underwent first revision THA between 2004 and 2013, among which 146 hips with CoC bearings underwent revision. There were 92 hips with third-generation ceramic bearings and 54 hips with fourth-generation ceramic bearings. The major reasons for CoC THA revisions were ceramic fracture and loosening of the cup or stem. When ceramic fracture, squeaking, incorrect ceramic insertion, and unexplained pain were defined as directly related or potentially related to ceramic use, 28.8% (42/146) of CoC revisions were associated with bearing-related problems. Among the third-generation ceramic bearings, revision was performed in 41.3% (38/92) of cases owing to bearing-related problems whereas revisions were performed for only 7.4% (4/54) of cases with fourth-generation ceramic bearings owing to bearing-related problems (p < 0.001). Younger age, lower American Society of Anesthesiologists (ASA) grade, and preoperative diagnosis of osteonecrosis were factors related to CoC THA revisions due to bearing-related problems.
format article
author Sang-Min Kim
Kee Hyung Rhyu
Jeong Joon Yoo
Seung-Jae Lim
Je Hyun Yoo
Suc Hyun Kweon
Kyung-Jae Lee
Seung-Beom Han
author_facet Sang-Min Kim
Kee Hyung Rhyu
Jeong Joon Yoo
Seung-Jae Lim
Je Hyun Yoo
Suc Hyun Kweon
Kyung-Jae Lee
Seung-Beom Han
author_sort Sang-Min Kim
title The reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data
title_short The reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data
title_full The reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data
title_fullStr The reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data
title_full_unstemmed The reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data
title_sort reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/43ea694be14d41c9a50dd9ca20e78e9a
work_keys_str_mv AT sangminkim thereasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT keehyungrhyu thereasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT jeongjoonyoo thereasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT seungjaelim thereasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT jehyunyoo thereasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT suchyunkweon thereasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT kyungjaelee thereasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT seungbeomhan thereasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT sangminkim reasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT keehyungrhyu reasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT jeongjoonyoo reasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT seungjaelim reasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT jehyunyoo reasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT suchyunkweon reasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT kyungjaelee reasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
AT seungbeomhan reasonsforceramiconceramicrevisionsbetweenthethirdandfourthgenerationbearingsintotalhiparthroplastyfrommulticentricregistrydata
_version_ 1718393267796574208