Experimental and Calculation Studies of Main Line Oil Pumps Efficiency Change Due to Smooth Coatings

The study is dedicated to investigation of impact made by smooth coatings applied on the flow part surfaces of main line oil pumps with reference to energy efficiency performance of the said pumps. Loctite 7227 and Belzona 1341 were used as coatings which allowed to significantly reduce the roughnes...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Akimov S. V.
Formato: article
Lenguaje:EN
FR
Publicado: EDP Sciences 2021
Materias:
Acceso en línea:https://doaj.org/article/43fffd933c774909a02be7657804858d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:43fffd933c774909a02be7657804858d
record_format dspace
spelling oai:doaj.org-article:43fffd933c774909a02be7657804858d2021-11-12T11:44:23ZExperimental and Calculation Studies of Main Line Oil Pumps Efficiency Change Due to Smooth Coatings2267-124210.1051/e3sconf/202132004012https://doaj.org/article/43fffd933c774909a02be7657804858d2021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/96/e3sconf_esei2021_04012.pdfhttps://doaj.org/toc/2267-1242The study is dedicated to investigation of impact made by smooth coatings applied on the flow part surfaces of main line oil pumps with reference to energy efficiency performance of the said pumps. Loctite 7227 and Belzona 1341 were used as coatings which allowed to significantly reduce the roughness of the coated surfaces. Distinctive features of the abovementioned coatings are low cost and easy application (by spraying or using a brush) which is, despite lack of hydrophobic behavior, makes them applicable for use in operating conditions at oil pumping stations. Experimental studies have been carried out including coatings testing on full-scale pumps MOL 1250-60 and MOL 10000-210. The results of the experimental studies have been compared with the results of analytic calculations. Based on the results of the studies the applicability of smooth non-hydrophobic coatings was confirmed on condition of their application on the surfaces of volute flow parts of mainline oil pumps. Besides, the suggested analytical procedure for coatings efficiency evaluation was validated.Akimov S. V.EDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 320, p 04012 (2021)
institution DOAJ
collection DOAJ
language EN
FR
topic Environmental sciences
GE1-350
spellingShingle Environmental sciences
GE1-350
Akimov S. V.
Experimental and Calculation Studies of Main Line Oil Pumps Efficiency Change Due to Smooth Coatings
description The study is dedicated to investigation of impact made by smooth coatings applied on the flow part surfaces of main line oil pumps with reference to energy efficiency performance of the said pumps. Loctite 7227 and Belzona 1341 were used as coatings which allowed to significantly reduce the roughness of the coated surfaces. Distinctive features of the abovementioned coatings are low cost and easy application (by spraying or using a brush) which is, despite lack of hydrophobic behavior, makes them applicable for use in operating conditions at oil pumping stations. Experimental studies have been carried out including coatings testing on full-scale pumps MOL 1250-60 and MOL 10000-210. The results of the experimental studies have been compared with the results of analytic calculations. Based on the results of the studies the applicability of smooth non-hydrophobic coatings was confirmed on condition of their application on the surfaces of volute flow parts of mainline oil pumps. Besides, the suggested analytical procedure for coatings efficiency evaluation was validated.
format article
author Akimov S. V.
author_facet Akimov S. V.
author_sort Akimov S. V.
title Experimental and Calculation Studies of Main Line Oil Pumps Efficiency Change Due to Smooth Coatings
title_short Experimental and Calculation Studies of Main Line Oil Pumps Efficiency Change Due to Smooth Coatings
title_full Experimental and Calculation Studies of Main Line Oil Pumps Efficiency Change Due to Smooth Coatings
title_fullStr Experimental and Calculation Studies of Main Line Oil Pumps Efficiency Change Due to Smooth Coatings
title_full_unstemmed Experimental and Calculation Studies of Main Line Oil Pumps Efficiency Change Due to Smooth Coatings