Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320

Background: Computed tomography angiography (CTA) in infants is considered one of the most challenging radiological examinations due to difficulties in balancing start delay, contrast agent (CA) volume and flow in order to achieve optimal opacification of the large vessels. This study aimed to compa...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Marian Pop
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/44e985d3d3364bebb412e6accdcc6daf
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Background: Computed tomography angiography (CTA) in infants is considered one of the most challenging radiological examinations due to difficulties in balancing start delay, contrast agent (CA) volume and flow in order to achieve optimal opacification of the large vessels. This study aimed to compare the contrast enhancement achieved by four CAs when taking into consideration CA injection parameters and patient characteristics. Methods: We performed a retrospective assessment of forty-eight consecutive cardiothoracic CTAs performed for aortic arch evaluation on children aged 0–1 year. All examinations were performed using the same 64-slice scanner and power injector using the bolus tracking technique. Axial 0.6 mm slices were used to measure large vessel enhancement using regions of interest at the level of the main pulmonary artery, ascending and descending aorta. The recorded variables included anthropometric measurements, CA type, flow rate, volume, and the average Hounsfield unit (HU) values of the blood pool. Descriptive statistics are presented as averages and standard deviations (SD) for normal distributed data or otherwise as medians and interquartile ranges (IQRs). Results: We found no statistically significant differences between age and anthropometric parameters when looking at different CAs. The median CA volume was 7 (IQR, 7–9) mL with the average flow rate of 0.94 (SD, 0.23) mL/s. Ascending aorta average HU values were 605.9 (SD, 177.23) for Iomeprol 350, 626 (SD, 183.83) for Ioversol 350, 530.83 (SD, 175.56) for Iopromide 370 and 354.91 (SD, 115.81) for Iodixanol 320. The difference in HU value for Iodixanol 320 compared to the other CAs was statistically significant. Similar differences were found for the other vascular structures. Conclusion: In CTA of infants suspected of aortic arch hypoplasia/coarctation, Iodixanol 320 provided up to 40% less enhancement of the great vessels when compared to Iomeprol 350, Ioversol 350 and Iopromide 370.