Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320
Background: Computed tomography angiography (CTA) in infants is considered one of the most challenging radiological examinations due to difficulties in balancing start delay, contrast agent (CA) volume and flow in order to achieve optimal opacification of the large vessels. This study aimed to compa...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/44e985d3d3364bebb412e6accdcc6daf |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:44e985d3d3364bebb412e6accdcc6daf |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:44e985d3d3364bebb412e6accdcc6daf2021-11-25T17:13:50ZCardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 32010.3390/children81109492227-9067https://doaj.org/article/44e985d3d3364bebb412e6accdcc6daf2021-10-01T00:00:00Zhttps://www.mdpi.com/2227-9067/8/11/949https://doaj.org/toc/2227-9067Background: Computed tomography angiography (CTA) in infants is considered one of the most challenging radiological examinations due to difficulties in balancing start delay, contrast agent (CA) volume and flow in order to achieve optimal opacification of the large vessels. This study aimed to compare the contrast enhancement achieved by four CAs when taking into consideration CA injection parameters and patient characteristics. Methods: We performed a retrospective assessment of forty-eight consecutive cardiothoracic CTAs performed for aortic arch evaluation on children aged 0–1 year. All examinations were performed using the same 64-slice scanner and power injector using the bolus tracking technique. Axial 0.6 mm slices were used to measure large vessel enhancement using regions of interest at the level of the main pulmonary artery, ascending and descending aorta. The recorded variables included anthropometric measurements, CA type, flow rate, volume, and the average Hounsfield unit (HU) values of the blood pool. Descriptive statistics are presented as averages and standard deviations (SD) for normal distributed data or otherwise as medians and interquartile ranges (IQRs). Results: We found no statistically significant differences between age and anthropometric parameters when looking at different CAs. The median CA volume was 7 (IQR, 7–9) mL with the average flow rate of 0.94 (SD, 0.23) mL/s. Ascending aorta average HU values were 605.9 (SD, 177.23) for Iomeprol 350, 626 (SD, 183.83) for Ioversol 350, 530.83 (SD, 175.56) for Iopromide 370 and 354.91 (SD, 115.81) for Iodixanol 320. The difference in HU value for Iodixanol 320 compared to the other CAs was statistically significant. Similar differences were found for the other vascular structures. Conclusion: In CTA of infants suspected of aortic arch hypoplasia/coarctation, Iodixanol 320 provided up to 40% less enhancement of the great vessels when compared to Iomeprol 350, Ioversol 350 and Iopromide 370.Marian PopMDPI AGarticlecontrast agentscomputed tomography angiography(CTA)congenital cardiovascular malformationsaortic archPediatricsRJ1-570ENChildren, Vol 8, Iss 949, p 949 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
contrast agents computed tomography angiography(CTA) congenital cardiovascular malformations aortic arch Pediatrics RJ1-570 |
spellingShingle |
contrast agents computed tomography angiography(CTA) congenital cardiovascular malformations aortic arch Pediatrics RJ1-570 Marian Pop Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320 |
description |
Background: Computed tomography angiography (CTA) in infants is considered one of the most challenging radiological examinations due to difficulties in balancing start delay, contrast agent (CA) volume and flow in order to achieve optimal opacification of the large vessels. This study aimed to compare the contrast enhancement achieved by four CAs when taking into consideration CA injection parameters and patient characteristics. Methods: We performed a retrospective assessment of forty-eight consecutive cardiothoracic CTAs performed for aortic arch evaluation on children aged 0–1 year. All examinations were performed using the same 64-slice scanner and power injector using the bolus tracking technique. Axial 0.6 mm slices were used to measure large vessel enhancement using regions of interest at the level of the main pulmonary artery, ascending and descending aorta. The recorded variables included anthropometric measurements, CA type, flow rate, volume, and the average Hounsfield unit (HU) values of the blood pool. Descriptive statistics are presented as averages and standard deviations (SD) for normal distributed data or otherwise as medians and interquartile ranges (IQRs). Results: We found no statistically significant differences between age and anthropometric parameters when looking at different CAs. The median CA volume was 7 (IQR, 7–9) mL with the average flow rate of 0.94 (SD, 0.23) mL/s. Ascending aorta average HU values were 605.9 (SD, 177.23) for Iomeprol 350, 626 (SD, 183.83) for Ioversol 350, 530.83 (SD, 175.56) for Iopromide 370 and 354.91 (SD, 115.81) for Iodixanol 320. The difference in HU value for Iodixanol 320 compared to the other CAs was statistically significant. Similar differences were found for the other vascular structures. Conclusion: In CTA of infants suspected of aortic arch hypoplasia/coarctation, Iodixanol 320 provided up to 40% less enhancement of the great vessels when compared to Iomeprol 350, Ioversol 350 and Iopromide 370. |
format |
article |
author |
Marian Pop |
author_facet |
Marian Pop |
author_sort |
Marian Pop |
title |
Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320 |
title_short |
Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320 |
title_full |
Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320 |
title_fullStr |
Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320 |
title_full_unstemmed |
Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320 |
title_sort |
cardiothoracic cta in infants referred for aortic arch evaluation—retrospective comparison of iomeprol 350, ioversol 350, iopromide 370 and iodixanol 320 |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/44e985d3d3364bebb412e6accdcc6daf |
work_keys_str_mv |
AT marianpop cardiothoracicctaininfantsreferredforaorticarchevaluationretrospectivecomparisonofiomeprol350ioversol350iopromide370andiodixanol320 |
_version_ |
1718412583630798848 |