An ideal dielectric coat to avoid prosthesis RF-artefacts in Magnetic Resonance Imaging

Abstract The number of people submitted to total hip or knee arthroplasty increased in the last years and it is likely to grow further. Hence, the importance of a proper investigation tool that allows to determine and recognize the potential presence of perioperative and/or postoperative diseases be...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: U. Zanovello, L. Matekovits, L. Zilberti
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/45c62b041dd74287b7c48a40db272cde
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:45c62b041dd74287b7c48a40db272cde
record_format dspace
spelling oai:doaj.org-article:45c62b041dd74287b7c48a40db272cde2021-12-02T11:40:15ZAn ideal dielectric coat to avoid prosthesis RF-artefacts in Magnetic Resonance Imaging10.1038/s41598-017-00215-72045-2322https://doaj.org/article/45c62b041dd74287b7c48a40db272cde2017-03-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-00215-7https://doaj.org/toc/2045-2322Abstract The number of people submitted to total hip or knee arthroplasty increased in the last years and it is likely to grow further. Hence, the importance of a proper investigation tool that allows to determine and recognize the potential presence of perioperative and/or postoperative diseases becomes clear. Although the Magnetic Resonance Imaging (MRI) technique demonstrated several advantages over the other common tomography tools, it suffers from the arise of image artefacts if it is performed in presence of metallic prostheses. In particular, the so-called RF-artefacts are caused by the inhomogeneity in the radiofrequency magnetic field of MRI, due to the electric currents induced on the metal surface by the field itself. In this work, a near-zero permittivity dielectric coat is simulated to reduce those currents and, therefore, the RF-artefacts onset in the final image. Numerical results confirm that the dielectric coat strongly reduces the magnetic field inhomogeneity, suggesting a possible solution to a well-known problem in the MRI field.U. ZanovelloL. MatekovitsL. ZilbertiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-12 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
U. Zanovello
L. Matekovits
L. Zilberti
An ideal dielectric coat to avoid prosthesis RF-artefacts in Magnetic Resonance Imaging
description Abstract The number of people submitted to total hip or knee arthroplasty increased in the last years and it is likely to grow further. Hence, the importance of a proper investigation tool that allows to determine and recognize the potential presence of perioperative and/or postoperative diseases becomes clear. Although the Magnetic Resonance Imaging (MRI) technique demonstrated several advantages over the other common tomography tools, it suffers from the arise of image artefacts if it is performed in presence of metallic prostheses. In particular, the so-called RF-artefacts are caused by the inhomogeneity in the radiofrequency magnetic field of MRI, due to the electric currents induced on the metal surface by the field itself. In this work, a near-zero permittivity dielectric coat is simulated to reduce those currents and, therefore, the RF-artefacts onset in the final image. Numerical results confirm that the dielectric coat strongly reduces the magnetic field inhomogeneity, suggesting a possible solution to a well-known problem in the MRI field.
format article
author U. Zanovello
L. Matekovits
L. Zilberti
author_facet U. Zanovello
L. Matekovits
L. Zilberti
author_sort U. Zanovello
title An ideal dielectric coat to avoid prosthesis RF-artefacts in Magnetic Resonance Imaging
title_short An ideal dielectric coat to avoid prosthesis RF-artefacts in Magnetic Resonance Imaging
title_full An ideal dielectric coat to avoid prosthesis RF-artefacts in Magnetic Resonance Imaging
title_fullStr An ideal dielectric coat to avoid prosthesis RF-artefacts in Magnetic Resonance Imaging
title_full_unstemmed An ideal dielectric coat to avoid prosthesis RF-artefacts in Magnetic Resonance Imaging
title_sort ideal dielectric coat to avoid prosthesis rf-artefacts in magnetic resonance imaging
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/45c62b041dd74287b7c48a40db272cde
work_keys_str_mv AT uzanovello anidealdielectriccoattoavoidprosthesisrfartefactsinmagneticresonanceimaging
AT lmatekovits anidealdielectriccoattoavoidprosthesisrfartefactsinmagneticresonanceimaging
AT lzilberti anidealdielectriccoattoavoidprosthesisrfartefactsinmagneticresonanceimaging
AT uzanovello idealdielectriccoattoavoidprosthesisrfartefactsinmagneticresonanceimaging
AT lmatekovits idealdielectriccoattoavoidprosthesisrfartefactsinmagneticresonanceimaging
AT lzilberti idealdielectriccoattoavoidprosthesisrfartefactsinmagneticresonanceimaging
_version_ 1718395639124983808