Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger
Many researchers numerically investigated U-tube underground heat exchanger using a two-dimensional simplified pipe. However, a simplified model results in large errors compared to the data from construction sites. This research is carried out using a three-dimensional full-size model. A model valid...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
De Gruyter
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/45d0205a43ba407fa4d74ab95e92c231 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:45d0205a43ba407fa4d74ab95e92c231 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:45d0205a43ba407fa4d74ab95e92c2312021-12-05T14:11:02ZEffect of buried depth on thermal performance of a vertical U-tube underground heat exchanger2391-547110.1515/phys-2021-0033https://doaj.org/article/45d0205a43ba407fa4d74ab95e92c2312021-06-01T00:00:00Zhttps://doi.org/10.1515/phys-2021-0033https://doaj.org/toc/2391-5471Many researchers numerically investigated U-tube underground heat exchanger using a two-dimensional simplified pipe. However, a simplified model results in large errors compared to the data from construction sites. This research is carried out using a three-dimensional full-size model. A model validation is conducted by comparing with experimental data in summer. This article investigates the effects of fluid velocity and buried depth on the heat exchange rate in a vertical U-tube underground heat exchanger based on fluid–structure coupled simulations. Compared with the results at a flow rate of 0.4 m/s, the results of this research show that the heat transfer per buried depth at 1.0 m/s increases by 123.34%. With the increase of the buried depth from 80 to 140 m, the heat transfer per unit depth decreases by 9.72%.Yang LiZhang BoKlemeš Jiří JaromírLiu JieSong MeiyuWang JinDe Gruyterarticleburied depthcomputational fluid dynamicsfluid velocityground source heat pumpu-tube heat exchangerPhysicsQC1-999ENOpen Physics, Vol 19, Iss 1, Pp 327-330 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
buried depth computational fluid dynamics fluid velocity ground source heat pump u-tube heat exchanger Physics QC1-999 |
spellingShingle |
buried depth computational fluid dynamics fluid velocity ground source heat pump u-tube heat exchanger Physics QC1-999 Yang Li Zhang Bo Klemeš Jiří Jaromír Liu Jie Song Meiyu Wang Jin Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger |
description |
Many researchers numerically investigated U-tube underground heat exchanger using a two-dimensional simplified pipe. However, a simplified model results in large errors compared to the data from construction sites. This research is carried out using a three-dimensional full-size model. A model validation is conducted by comparing with experimental data in summer. This article investigates the effects of fluid velocity and buried depth on the heat exchange rate in a vertical U-tube underground heat exchanger based on fluid–structure coupled simulations. Compared with the results at a flow rate of 0.4 m/s, the results of this research show that the heat transfer per buried depth at 1.0 m/s increases by 123.34%. With the increase of the buried depth from 80 to 140 m, the heat transfer per unit depth decreases by 9.72%. |
format |
article |
author |
Yang Li Zhang Bo Klemeš Jiří Jaromír Liu Jie Song Meiyu Wang Jin |
author_facet |
Yang Li Zhang Bo Klemeš Jiří Jaromír Liu Jie Song Meiyu Wang Jin |
author_sort |
Yang Li |
title |
Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger |
title_short |
Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger |
title_full |
Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger |
title_fullStr |
Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger |
title_full_unstemmed |
Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger |
title_sort |
effect of buried depth on thermal performance of a vertical u-tube underground heat exchanger |
publisher |
De Gruyter |
publishDate |
2021 |
url |
https://doaj.org/article/45d0205a43ba407fa4d74ab95e92c231 |
work_keys_str_mv |
AT yangli effectofburieddepthonthermalperformanceofaverticalutubeundergroundheatexchanger AT zhangbo effectofburieddepthonthermalperformanceofaverticalutubeundergroundheatexchanger AT klemesjirijaromir effectofburieddepthonthermalperformanceofaverticalutubeundergroundheatexchanger AT liujie effectofburieddepthonthermalperformanceofaverticalutubeundergroundheatexchanger AT songmeiyu effectofburieddepthonthermalperformanceofaverticalutubeundergroundheatexchanger AT wangjin effectofburieddepthonthermalperformanceofaverticalutubeundergroundheatexchanger |
_version_ |
1718371471580987392 |