Aerosolization and Fluid Spillage During Phacoemulsification in Human Subjects

Jasper Ka Wai Wong,1 Jeremy Sze Wai John Kwok,1 Jonathan Cheuk Hung Chan,1 Kendrick Co Shih,1 ‪Renyuan Qin,2 Denvid Lau,2 Jimmy Shiu Ming Lai1 1Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong; 2Department of Architecture and Civil Engineering, College...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Wong JKW, Kwok JSWJ, Chan JCH, Shih KC, Qin, Lau D, Lai JSM
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2021
Materias:
Acceso en línea:https://doaj.org/article/468b3b645da34ca6982367b9fe565609
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:468b3b645da34ca6982367b9fe565609
record_format dspace
spelling oai:doaj.org-article:468b3b645da34ca6982367b9fe5656092021-12-02T14:08:52ZAerosolization and Fluid Spillage During Phacoemulsification in Human Subjects1177-5483https://doaj.org/article/468b3b645da34ca6982367b9fe5656092021-01-01T00:00:00Zhttps://www.dovepress.com/aerosolization-and-fluid-spillage-during-phacoemulsification-in-human--peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Jasper Ka Wai Wong,1 Jeremy Sze Wai John Kwok,1 Jonathan Cheuk Hung Chan,1 Kendrick Co Shih,1 ‪Renyuan Qin,2 Denvid Lau,2 Jimmy Shiu Ming Lai1 1Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong; 2Department of Architecture and Civil Engineering, College of Engineering, City University of Hong Kong, Hong KongCorrespondence: Jimmy Shiu Ming LaiDepartment of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Room 301, Block B, Cyberport 4, 100 Cyberport Road, Hong KongTel +852 39621405Email smjlai@netvigator.comBackground: Concerns had been raised for the potential hazard of SARS-CoV-2 transmissions via aerosols and fluid droplets during cataract surgeries amid the COVID-19 pandemic. This study aims to evaluate the rate of visible aerosol generation and fluid spillage from surgical wounds during phacoemulsification in human subjects.Methods: This is a prospective consecutive interventional case series. High-resolution video captures of 30 consecutive uncomplicated phacoemulsification surgeries, performed by 3 board-certified specialists in ophthalmology, were assessed by 2 independent and masked investigators for intraoperative aerosolization and fluid spillage. Water-contact indicator tape was mounted on the base of the operating microscope, around the objective lens, to detect any fluid contact.Results: No visible intraoperative aerosolization was detected in any of the cases, irrespective of different surgical practices among the surgeons with regard to wound size and position, lens fragmentation technique, power settings and means of ocular lubrication, or the different densities of cataract encountered. Large droplets spillage was noted from the paracentesis wounds in 70% of the cases. For all cases where fluid spill was detected on video, there was no fluid contact detected on the water-contact indicator tape.Conclusion: Visible aerosolization was not detected during phacoemulsification in our case series. Although the rate of fluid spillage was high, the lack of detectable contact with the indicator tape suggested that these large droplets posed no significant infectious risks to members of the surgical team.Keywords: phacoemulsification, aerosols, aerosolization, droplets, COVIDWong JKWKwok JSWJChan JCHShih KCQinLau DLai JSMDove Medical PressarticlephacoemulsificationaerosolsaerosolizationdropletscovidOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 15, Pp 307-313 (2021)
institution DOAJ
collection DOAJ
language EN
topic phacoemulsification
aerosols
aerosolization
droplets
covid
Ophthalmology
RE1-994
spellingShingle phacoemulsification
aerosols
aerosolization
droplets
covid
Ophthalmology
RE1-994
Wong JKW
Kwok JSWJ
Chan JCH
Shih KC
Qin
Lau D
Lai JSM
Aerosolization and Fluid Spillage During Phacoemulsification in Human Subjects
description Jasper Ka Wai Wong,1 Jeremy Sze Wai John Kwok,1 Jonathan Cheuk Hung Chan,1 Kendrick Co Shih,1 ‪Renyuan Qin,2 Denvid Lau,2 Jimmy Shiu Ming Lai1 1Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong; 2Department of Architecture and Civil Engineering, College of Engineering, City University of Hong Kong, Hong KongCorrespondence: Jimmy Shiu Ming LaiDepartment of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Room 301, Block B, Cyberport 4, 100 Cyberport Road, Hong KongTel +852 39621405Email smjlai@netvigator.comBackground: Concerns had been raised for the potential hazard of SARS-CoV-2 transmissions via aerosols and fluid droplets during cataract surgeries amid the COVID-19 pandemic. This study aims to evaluate the rate of visible aerosol generation and fluid spillage from surgical wounds during phacoemulsification in human subjects.Methods: This is a prospective consecutive interventional case series. High-resolution video captures of 30 consecutive uncomplicated phacoemulsification surgeries, performed by 3 board-certified specialists in ophthalmology, were assessed by 2 independent and masked investigators for intraoperative aerosolization and fluid spillage. Water-contact indicator tape was mounted on the base of the operating microscope, around the objective lens, to detect any fluid contact.Results: No visible intraoperative aerosolization was detected in any of the cases, irrespective of different surgical practices among the surgeons with regard to wound size and position, lens fragmentation technique, power settings and means of ocular lubrication, or the different densities of cataract encountered. Large droplets spillage was noted from the paracentesis wounds in 70% of the cases. For all cases where fluid spill was detected on video, there was no fluid contact detected on the water-contact indicator tape.Conclusion: Visible aerosolization was not detected during phacoemulsification in our case series. Although the rate of fluid spillage was high, the lack of detectable contact with the indicator tape suggested that these large droplets posed no significant infectious risks to members of the surgical team.Keywords: phacoemulsification, aerosols, aerosolization, droplets, COVID
format article
author Wong JKW
Kwok JSWJ
Chan JCH
Shih KC
Qin
Lau D
Lai JSM
author_facet Wong JKW
Kwok JSWJ
Chan JCH
Shih KC
Qin
Lau D
Lai JSM
author_sort Wong JKW
title Aerosolization and Fluid Spillage During Phacoemulsification in Human Subjects
title_short Aerosolization and Fluid Spillage During Phacoemulsification in Human Subjects
title_full Aerosolization and Fluid Spillage During Phacoemulsification in Human Subjects
title_fullStr Aerosolization and Fluid Spillage During Phacoemulsification in Human Subjects
title_full_unstemmed Aerosolization and Fluid Spillage During Phacoemulsification in Human Subjects
title_sort aerosolization and fluid spillage during phacoemulsification in human subjects
publisher Dove Medical Press
publishDate 2021
url https://doaj.org/article/468b3b645da34ca6982367b9fe565609
work_keys_str_mv AT wongjkw aerosolizationandfluidspillageduringphacoemulsificationinhumansubjects
AT kwokjswj aerosolizationandfluidspillageduringphacoemulsificationinhumansubjects
AT chanjch aerosolizationandfluidspillageduringphacoemulsificationinhumansubjects
AT shihkc aerosolizationandfluidspillageduringphacoemulsificationinhumansubjects
AT qin aerosolizationandfluidspillageduringphacoemulsificationinhumansubjects
AT laud aerosolizationandfluidspillageduringphacoemulsificationinhumansubjects
AT laijsm aerosolizationandfluidspillageduringphacoemulsificationinhumansubjects
_version_ 1718391903016189952