Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes
Abstract The purpose of this study was to compare the performance of arrival-time-insensitive (ATI) and arrival-time-sensitive (ATS) computed tomography perfusion (CTP) algorithms in Philips IntelliSpace Portal (v9, ISP) and to investigate optimal thresholds for ATI regarding the prediction of final...
Guardado en:
Autores principales: | , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2020
|
Materias: | |
Acceso en línea: | https://doaj.org/article/46d26f65adfa47dd9a12a362a803f3fe |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:46d26f65adfa47dd9a12a362a803f3fe |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:46d26f65adfa47dd9a12a362a803f3fe2021-12-02T17:52:23ZComparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes10.1038/s41598-020-66041-62045-2322https://doaj.org/article/46d26f65adfa47dd9a12a362a803f3fe2020-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-66041-6https://doaj.org/toc/2045-2322Abstract The purpose of this study was to compare the performance of arrival-time-insensitive (ATI) and arrival-time-sensitive (ATS) computed tomography perfusion (CTP) algorithms in Philips IntelliSpace Portal (v9, ISP) and to investigate optimal thresholds for ATI regarding the prediction of final infarct volume (FIV). Retrospective, single-center study with 54 patients (mean 67.0 ± 13.1 years, 68.5% male) who received Stroke-CT/CTP-imaging between 2010 and 2018 with occlusion of the middle cerebral artery in the M1-/proximal M2-segment or terminal internal carotid artery. FIV was determined on short-term follow-up imaging in two patient groups: A) not attempted or failed mechanical thrombectomy (MT) and B) successful MT. ATS (default settings) and ATI (full-range of threshold settings regarding FIV prediction) maps were coregistered in 3D with FIV using voxel-wise overlap measurement. Based on an average imaging follow-up of 2.6 ± 2.1 days, the estimation regarding penumbra (group A, ATI: r = 0.63/0.69, ATS: r = 0.64) and infarct core (group B, ATI: r = 0.60/0.68, ATS: r = 0.63) was slightly higher in ATI but the effect was not significant (p > 0.05). Regarding ATI, Tmax (AUC 0.9) was the best estimator of the penumbra (group A), CBF relative to the contralateral hemisphere (AUC 0.80) showed the best estimation of the infarct core (group B). There was a broad range of thresholds of optimal ATI settings in both groups. Prediction of FIV with ATI was slightly better compared to ATS. However, this difference was not significant. Since ATI showed a broad range of optimal thresholds, exact thresholds regarding the ATI algorithm should be evaluated in further prospective, clinical studies.Lenhard PennigFrank ThieleLukas GoertzKai Roman LaukampMichael PerkuhnChristoph KabbaschMarc SchlamannGereon Rudolf FinkJan BorggrefeNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 10, Iss 1, Pp 1-9 (2020) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Lenhard Pennig Frank Thiele Lukas Goertz Kai Roman Laukamp Michael Perkuhn Christoph Kabbasch Marc Schlamann Gereon Rudolf Fink Jan Borggrefe Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes |
description |
Abstract The purpose of this study was to compare the performance of arrival-time-insensitive (ATI) and arrival-time-sensitive (ATS) computed tomography perfusion (CTP) algorithms in Philips IntelliSpace Portal (v9, ISP) and to investigate optimal thresholds for ATI regarding the prediction of final infarct volume (FIV). Retrospective, single-center study with 54 patients (mean 67.0 ± 13.1 years, 68.5% male) who received Stroke-CT/CTP-imaging between 2010 and 2018 with occlusion of the middle cerebral artery in the M1-/proximal M2-segment or terminal internal carotid artery. FIV was determined on short-term follow-up imaging in two patient groups: A) not attempted or failed mechanical thrombectomy (MT) and B) successful MT. ATS (default settings) and ATI (full-range of threshold settings regarding FIV prediction) maps were coregistered in 3D with FIV using voxel-wise overlap measurement. Based on an average imaging follow-up of 2.6 ± 2.1 days, the estimation regarding penumbra (group A, ATI: r = 0.63/0.69, ATS: r = 0.64) and infarct core (group B, ATI: r = 0.60/0.68, ATS: r = 0.63) was slightly higher in ATI but the effect was not significant (p > 0.05). Regarding ATI, Tmax (AUC 0.9) was the best estimator of the penumbra (group A), CBF relative to the contralateral hemisphere (AUC 0.80) showed the best estimation of the infarct core (group B). There was a broad range of thresholds of optimal ATI settings in both groups. Prediction of FIV with ATI was slightly better compared to ATS. However, this difference was not significant. Since ATI showed a broad range of optimal thresholds, exact thresholds regarding the ATI algorithm should be evaluated in further prospective, clinical studies. |
format |
article |
author |
Lenhard Pennig Frank Thiele Lukas Goertz Kai Roman Laukamp Michael Perkuhn Christoph Kabbasch Marc Schlamann Gereon Rudolf Fink Jan Borggrefe |
author_facet |
Lenhard Pennig Frank Thiele Lukas Goertz Kai Roman Laukamp Michael Perkuhn Christoph Kabbasch Marc Schlamann Gereon Rudolf Fink Jan Borggrefe |
author_sort |
Lenhard Pennig |
title |
Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes |
title_short |
Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes |
title_full |
Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes |
title_fullStr |
Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes |
title_full_unstemmed |
Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes |
title_sort |
comparison of accuracy of arrival-time-insensitive and arrival-time-sensitive ctp algorithms for prediction of infarct tissue volumes |
publisher |
Nature Portfolio |
publishDate |
2020 |
url |
https://doaj.org/article/46d26f65adfa47dd9a12a362a803f3fe |
work_keys_str_mv |
AT lenhardpennig comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes AT frankthiele comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes AT lukasgoertz comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes AT kairomanlaukamp comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes AT michaelperkuhn comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes AT christophkabbasch comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes AT marcschlamann comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes AT gereonrudolffink comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes AT janborggrefe comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes |
_version_ |
1718379222739714048 |