Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes

Abstract The purpose of this study was to compare the performance of arrival-time-insensitive (ATI) and arrival-time-sensitive (ATS) computed tomography perfusion (CTP) algorithms in Philips IntelliSpace Portal (v9, ISP) and to investigate optimal thresholds for ATI regarding the prediction of final...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Lenhard Pennig, Frank Thiele, Lukas Goertz, Kai Roman Laukamp, Michael Perkuhn, Christoph Kabbasch, Marc Schlamann, Gereon Rudolf Fink, Jan Borggrefe
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2020
Materias:
R
Q
Acceso en línea:https://doaj.org/article/46d26f65adfa47dd9a12a362a803f3fe
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:46d26f65adfa47dd9a12a362a803f3fe
record_format dspace
spelling oai:doaj.org-article:46d26f65adfa47dd9a12a362a803f3fe2021-12-02T17:52:23ZComparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes10.1038/s41598-020-66041-62045-2322https://doaj.org/article/46d26f65adfa47dd9a12a362a803f3fe2020-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-66041-6https://doaj.org/toc/2045-2322Abstract The purpose of this study was to compare the performance of arrival-time-insensitive (ATI) and arrival-time-sensitive (ATS) computed tomography perfusion (CTP) algorithms in Philips IntelliSpace Portal (v9, ISP) and to investigate optimal thresholds for ATI regarding the prediction of final infarct volume (FIV). Retrospective, single-center study with 54 patients (mean 67.0 ± 13.1 years, 68.5% male) who received Stroke-CT/CTP-imaging between 2010 and 2018 with occlusion of the middle cerebral artery in the M1-/proximal M2-segment or terminal internal carotid artery. FIV was determined on short-term follow-up imaging in two patient groups: A) not attempted or failed mechanical thrombectomy (MT) and B) successful MT. ATS (default settings) and ATI (full-range of threshold settings regarding FIV prediction) maps were coregistered in 3D with FIV using voxel-wise overlap measurement. Based on an average imaging follow-up of 2.6 ± 2.1 days, the estimation regarding penumbra (group A, ATI: r = 0.63/0.69, ATS: r = 0.64) and infarct core (group B, ATI: r = 0.60/0.68, ATS: r = 0.63) was slightly higher in ATI but the effect was not significant (p > 0.05). Regarding ATI, Tmax (AUC 0.9) was the best estimator of the penumbra (group A), CBF relative to the contralateral hemisphere (AUC 0.80) showed the best estimation of the infarct core (group B). There was a broad range of thresholds of optimal ATI settings in both groups. Prediction of FIV with ATI was slightly better compared to ATS. However, this difference was not significant. Since ATI showed a broad range of optimal thresholds, exact thresholds regarding the ATI algorithm should be evaluated in further prospective, clinical studies.Lenhard PennigFrank ThieleLukas GoertzKai Roman LaukampMichael PerkuhnChristoph KabbaschMarc SchlamannGereon Rudolf FinkJan BorggrefeNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 10, Iss 1, Pp 1-9 (2020)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Lenhard Pennig
Frank Thiele
Lukas Goertz
Kai Roman Laukamp
Michael Perkuhn
Christoph Kabbasch
Marc Schlamann
Gereon Rudolf Fink
Jan Borggrefe
Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes
description Abstract The purpose of this study was to compare the performance of arrival-time-insensitive (ATI) and arrival-time-sensitive (ATS) computed tomography perfusion (CTP) algorithms in Philips IntelliSpace Portal (v9, ISP) and to investigate optimal thresholds for ATI regarding the prediction of final infarct volume (FIV). Retrospective, single-center study with 54 patients (mean 67.0 ± 13.1 years, 68.5% male) who received Stroke-CT/CTP-imaging between 2010 and 2018 with occlusion of the middle cerebral artery in the M1-/proximal M2-segment or terminal internal carotid artery. FIV was determined on short-term follow-up imaging in two patient groups: A) not attempted or failed mechanical thrombectomy (MT) and B) successful MT. ATS (default settings) and ATI (full-range of threshold settings regarding FIV prediction) maps were coregistered in 3D with FIV using voxel-wise overlap measurement. Based on an average imaging follow-up of 2.6 ± 2.1 days, the estimation regarding penumbra (group A, ATI: r = 0.63/0.69, ATS: r = 0.64) and infarct core (group B, ATI: r = 0.60/0.68, ATS: r = 0.63) was slightly higher in ATI but the effect was not significant (p > 0.05). Regarding ATI, Tmax (AUC 0.9) was the best estimator of the penumbra (group A), CBF relative to the contralateral hemisphere (AUC 0.80) showed the best estimation of the infarct core (group B). There was a broad range of thresholds of optimal ATI settings in both groups. Prediction of FIV with ATI was slightly better compared to ATS. However, this difference was not significant. Since ATI showed a broad range of optimal thresholds, exact thresholds regarding the ATI algorithm should be evaluated in further prospective, clinical studies.
format article
author Lenhard Pennig
Frank Thiele
Lukas Goertz
Kai Roman Laukamp
Michael Perkuhn
Christoph Kabbasch
Marc Schlamann
Gereon Rudolf Fink
Jan Borggrefe
author_facet Lenhard Pennig
Frank Thiele
Lukas Goertz
Kai Roman Laukamp
Michael Perkuhn
Christoph Kabbasch
Marc Schlamann
Gereon Rudolf Fink
Jan Borggrefe
author_sort Lenhard Pennig
title Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes
title_short Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes
title_full Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes
title_fullStr Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes
title_full_unstemmed Comparison of Accuracy of Arrival-Time-Insensitive and Arrival-Time-Sensitive CTP Algorithms for Prediction of Infarct Tissue Volumes
title_sort comparison of accuracy of arrival-time-insensitive and arrival-time-sensitive ctp algorithms for prediction of infarct tissue volumes
publisher Nature Portfolio
publishDate 2020
url https://doaj.org/article/46d26f65adfa47dd9a12a362a803f3fe
work_keys_str_mv AT lenhardpennig comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes
AT frankthiele comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes
AT lukasgoertz comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes
AT kairomanlaukamp comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes
AT michaelperkuhn comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes
AT christophkabbasch comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes
AT marcschlamann comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes
AT gereonrudolffink comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes
AT janborggrefe comparisonofaccuracyofarrivaltimeinsensitiveandarrivaltimesensitivectpalgorithmsforpredictionofinfarcttissuevolumes
_version_ 1718379222739714048