Copper Surface Treatment in Metal-Polymer Direct Molding Technology

The preparation technology of micro-nano structure on copper surface is studied and optimized. Aqueous solution containing sodium carbonate and sodium molybdate is used as electrolyte, and the copper sample is anodized at a constant voltage to form a layer of oxidation on the copper surface. Then, t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: GUO Rongsheng, HU Guanghong, RONG Jian, WANG Yuanlong
Formato: article
Lenguaje:ZH
Publicado: Editorial Office of Journal of Shanghai Jiao Tong University 2021
Materias:
Acceso en línea:https://doaj.org/article/46ddab8adea24df78147d8b740fffe01
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:46ddab8adea24df78147d8b740fffe01
record_format dspace
spelling oai:doaj.org-article:46ddab8adea24df78147d8b740fffe012021-11-04T09:35:15ZCopper Surface Treatment in Metal-Polymer Direct Molding Technology1006-246710.16183/j.cnki.jsjtu.2019.185https://doaj.org/article/46ddab8adea24df78147d8b740fffe012021-01-01T00:00:00Zhttp://xuebao.sjtu.edu.cn/CN/10.16183/j.cnki.jsjtu.2019.185https://doaj.org/toc/1006-2467The preparation technology of micro-nano structure on copper surface is studied and optimized. Aqueous solution containing sodium carbonate and sodium molybdate is used as electrolyte, and the copper sample is anodized at a constant voltage to form a layer of oxidation on the copper surface. Then, the copper surface is treated with aqueous solution containing phosphate and sodium dihydrogen phosphate as corrosion solution to obtain a micro-nano structure on the copper. The surface is observed by using a scanning electron microscope. Finally, the analysis software is used to analyze the scanning electron microscope image to calculate the micro-nano structure pores on the copper surface. The results show that when the anodizing voltage is 15 V, the anodizing time is 20 min, the phosphoric acid mass fraction is 20%, and the corrosion time is 30 min, the copper surface is relatively smooth, and the porosity reaches 25.77%. Orthogonal experiments demonstrate that the type, concentration of the corrosive solution, and etching time have a great effect, while the anodizing electrolyte, voltage and electrolysis have no significant effect on the porosity. Using a combination of anodic oxidation and chemical corrosion, micro and nano junctions with uniform and high porosity can be prepared on the copper surface.GUO RongshengHU GuanghongRONG JianWANG YuanlongEditorial Office of Journal of Shanghai Jiao Tong Universityarticlecoppersurface treatmentnano injection moldinganodic oxidationmicro-nano structureEngineering (General). Civil engineering (General)TA1-2040Chemical engineeringTP155-156Naval architecture. Shipbuilding. Marine engineeringVM1-989ZHShanghai Jiaotong Daxue xuebao, Vol 55, Iss 01, Pp 96-102 (2021)
institution DOAJ
collection DOAJ
language ZH
topic copper
surface treatment
nano injection molding
anodic oxidation
micro-nano structure
Engineering (General). Civil engineering (General)
TA1-2040
Chemical engineering
TP155-156
Naval architecture. Shipbuilding. Marine engineering
VM1-989
spellingShingle copper
surface treatment
nano injection molding
anodic oxidation
micro-nano structure
Engineering (General). Civil engineering (General)
TA1-2040
Chemical engineering
TP155-156
Naval architecture. Shipbuilding. Marine engineering
VM1-989
GUO Rongsheng
HU Guanghong
RONG Jian
WANG Yuanlong
Copper Surface Treatment in Metal-Polymer Direct Molding Technology
description The preparation technology of micro-nano structure on copper surface is studied and optimized. Aqueous solution containing sodium carbonate and sodium molybdate is used as electrolyte, and the copper sample is anodized at a constant voltage to form a layer of oxidation on the copper surface. Then, the copper surface is treated with aqueous solution containing phosphate and sodium dihydrogen phosphate as corrosion solution to obtain a micro-nano structure on the copper. The surface is observed by using a scanning electron microscope. Finally, the analysis software is used to analyze the scanning electron microscope image to calculate the micro-nano structure pores on the copper surface. The results show that when the anodizing voltage is 15 V, the anodizing time is 20 min, the phosphoric acid mass fraction is 20%, and the corrosion time is 30 min, the copper surface is relatively smooth, and the porosity reaches 25.77%. Orthogonal experiments demonstrate that the type, concentration of the corrosive solution, and etching time have a great effect, while the anodizing electrolyte, voltage and electrolysis have no significant effect on the porosity. Using a combination of anodic oxidation and chemical corrosion, micro and nano junctions with uniform and high porosity can be prepared on the copper surface.
format article
author GUO Rongsheng
HU Guanghong
RONG Jian
WANG Yuanlong
author_facet GUO Rongsheng
HU Guanghong
RONG Jian
WANG Yuanlong
author_sort GUO Rongsheng
title Copper Surface Treatment in Metal-Polymer Direct Molding Technology
title_short Copper Surface Treatment in Metal-Polymer Direct Molding Technology
title_full Copper Surface Treatment in Metal-Polymer Direct Molding Technology
title_fullStr Copper Surface Treatment in Metal-Polymer Direct Molding Technology
title_full_unstemmed Copper Surface Treatment in Metal-Polymer Direct Molding Technology
title_sort copper surface treatment in metal-polymer direct molding technology
publisher Editorial Office of Journal of Shanghai Jiao Tong University
publishDate 2021
url https://doaj.org/article/46ddab8adea24df78147d8b740fffe01
work_keys_str_mv AT guorongsheng coppersurfacetreatmentinmetalpolymerdirectmoldingtechnology
AT huguanghong coppersurfacetreatmentinmetalpolymerdirectmoldingtechnology
AT rongjian coppersurfacetreatmentinmetalpolymerdirectmoldingtechnology
AT wangyuanlong coppersurfacetreatmentinmetalpolymerdirectmoldingtechnology
_version_ 1718444956845080576