Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model
Due to their convenience, water measuring structures have become an important means of measuring water in irrigation canal systems However, relevant research on upstream and downstream water-depth monitoring point locations is scarce. Our study aims to determine the functional relationship between t...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/474982c276b04cddb8d25931775c741c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:474982c276b04cddb8d25931775c741c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:474982c276b04cddb8d25931775c741c2021-11-11T19:57:18ZAssessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model10.3390/w132131022073-4441https://doaj.org/article/474982c276b04cddb8d25931775c741c2021-11-01T00:00:00Zhttps://www.mdpi.com/2073-4441/13/21/3102https://doaj.org/toc/2073-4441Due to their convenience, water measuring structures have become an important means of measuring water in irrigation canal systems However, relevant research on upstream and downstream water-depth monitoring point locations is scarce. Our study aims to determine the functional relationship between the locations of the water-depth monitoring points and the opening width of the sluice. We established 14 trunk-channel and branch-channel hydrodynamic models. The locations of the water-depth monitoring points for the upstream and downstream reaches and their hydraulic characteristics were assessed using a numerical simulation and hydraulic test. The results showed that the locations of the upstream and downstream water-depth monitoring points were, respectively, 16.26 and 15.51 times the width of the sluice. The average error between the calculated flow rate and the simulated value was 14.37%; the average error between the flow rates calculated by the modified and the simulated values was 3.36%. To further verify the accuracy of the modified discharge calculation formula, by comparing the measured values, we reduced the average error of the modified formula by 19.29% compared with the standard formula. This research provides new insights into optimizing water measurements in irrigation canal systems. The results provide an engineering basis for the site selection of water-depth monitoring points that is suitable to be widely applied in the field.Hu XuZhenhua WangWenhao LiQiuliang WangMDPI AGarticlespecific location for measuringsimulation and field testirrigation canal systemmeasurement accuracyflow rate correction coefficientHydraulic engineeringTC1-978Water supply for domestic and industrial purposesTD201-500ENWater, Vol 13, Iss 3102, p 3102 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
specific location for measuring simulation and field test irrigation canal system measurement accuracy flow rate correction coefficient Hydraulic engineering TC1-978 Water supply for domestic and industrial purposes TD201-500 |
spellingShingle |
specific location for measuring simulation and field test irrigation canal system measurement accuracy flow rate correction coefficient Hydraulic engineering TC1-978 Water supply for domestic and industrial purposes TD201-500 Hu Xu Zhenhua Wang Wenhao Li Qiuliang Wang Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model |
description |
Due to their convenience, water measuring structures have become an important means of measuring water in irrigation canal systems However, relevant research on upstream and downstream water-depth monitoring point locations is scarce. Our study aims to determine the functional relationship between the locations of the water-depth monitoring points and the opening width of the sluice. We established 14 trunk-channel and branch-channel hydrodynamic models. The locations of the water-depth monitoring points for the upstream and downstream reaches and their hydraulic characteristics were assessed using a numerical simulation and hydraulic test. The results showed that the locations of the upstream and downstream water-depth monitoring points were, respectively, 16.26 and 15.51 times the width of the sluice. The average error between the calculated flow rate and the simulated value was 14.37%; the average error between the flow rates calculated by the modified and the simulated values was 3.36%. To further verify the accuracy of the modified discharge calculation formula, by comparing the measured values, we reduced the average error of the modified formula by 19.29% compared with the standard formula. This research provides new insights into optimizing water measurements in irrigation canal systems. The results provide an engineering basis for the site selection of water-depth monitoring points that is suitable to be widely applied in the field. |
format |
article |
author |
Hu Xu Zhenhua Wang Wenhao Li Qiuliang Wang |
author_facet |
Hu Xu Zhenhua Wang Wenhao Li Qiuliang Wang |
author_sort |
Hu Xu |
title |
Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model |
title_short |
Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model |
title_full |
Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model |
title_fullStr |
Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model |
title_full_unstemmed |
Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model |
title_sort |
assessment of water measurements in an irrigation canal system based on experimental data and the cfd model |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/474982c276b04cddb8d25931775c741c |
work_keys_str_mv |
AT huxu assessmentofwatermeasurementsinanirrigationcanalsystembasedonexperimentaldataandthecfdmodel AT zhenhuawang assessmentofwatermeasurementsinanirrigationcanalsystembasedonexperimentaldataandthecfdmodel AT wenhaoli assessmentofwatermeasurementsinanirrigationcanalsystembasedonexperimentaldataandthecfdmodel AT qiuliangwang assessmentofwatermeasurementsinanirrigationcanalsystembasedonexperimentaldataandthecfdmodel |
_version_ |
1718431343672557568 |