Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model

Due to their convenience, water measuring structures have become an important means of measuring water in irrigation canal systems However, relevant research on upstream and downstream water-depth monitoring point locations is scarce. Our study aims to determine the functional relationship between t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Hu Xu, Zhenhua Wang, Wenhao Li, Qiuliang Wang
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/474982c276b04cddb8d25931775c741c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:474982c276b04cddb8d25931775c741c
record_format dspace
spelling oai:doaj.org-article:474982c276b04cddb8d25931775c741c2021-11-11T19:57:18ZAssessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model10.3390/w132131022073-4441https://doaj.org/article/474982c276b04cddb8d25931775c741c2021-11-01T00:00:00Zhttps://www.mdpi.com/2073-4441/13/21/3102https://doaj.org/toc/2073-4441Due to their convenience, water measuring structures have become an important means of measuring water in irrigation canal systems However, relevant research on upstream and downstream water-depth monitoring point locations is scarce. Our study aims to determine the functional relationship between the locations of the water-depth monitoring points and the opening width of the sluice. We established 14 trunk-channel and branch-channel hydrodynamic models. The locations of the water-depth monitoring points for the upstream and downstream reaches and their hydraulic characteristics were assessed using a numerical simulation and hydraulic test. The results showed that the locations of the upstream and downstream water-depth monitoring points were, respectively, 16.26 and 15.51 times the width of the sluice. The average error between the calculated flow rate and the simulated value was 14.37%; the average error between the flow rates calculated by the modified and the simulated values was 3.36%. To further verify the accuracy of the modified discharge calculation formula, by comparing the measured values, we reduced the average error of the modified formula by 19.29% compared with the standard formula. This research provides new insights into optimizing water measurements in irrigation canal systems. The results provide an engineering basis for the site selection of water-depth monitoring points that is suitable to be widely applied in the field.Hu XuZhenhua WangWenhao LiQiuliang WangMDPI AGarticlespecific location for measuringsimulation and field testirrigation canal systemmeasurement accuracyflow rate correction coefficientHydraulic engineeringTC1-978Water supply for domestic and industrial purposesTD201-500ENWater, Vol 13, Iss 3102, p 3102 (2021)
institution DOAJ
collection DOAJ
language EN
topic specific location for measuring
simulation and field test
irrigation canal system
measurement accuracy
flow rate correction coefficient
Hydraulic engineering
TC1-978
Water supply for domestic and industrial purposes
TD201-500
spellingShingle specific location for measuring
simulation and field test
irrigation canal system
measurement accuracy
flow rate correction coefficient
Hydraulic engineering
TC1-978
Water supply for domestic and industrial purposes
TD201-500
Hu Xu
Zhenhua Wang
Wenhao Li
Qiuliang Wang
Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model
description Due to their convenience, water measuring structures have become an important means of measuring water in irrigation canal systems However, relevant research on upstream and downstream water-depth monitoring point locations is scarce. Our study aims to determine the functional relationship between the locations of the water-depth monitoring points and the opening width of the sluice. We established 14 trunk-channel and branch-channel hydrodynamic models. The locations of the water-depth monitoring points for the upstream and downstream reaches and their hydraulic characteristics were assessed using a numerical simulation and hydraulic test. The results showed that the locations of the upstream and downstream water-depth monitoring points were, respectively, 16.26 and 15.51 times the width of the sluice. The average error between the calculated flow rate and the simulated value was 14.37%; the average error between the flow rates calculated by the modified and the simulated values was 3.36%. To further verify the accuracy of the modified discharge calculation formula, by comparing the measured values, we reduced the average error of the modified formula by 19.29% compared with the standard formula. This research provides new insights into optimizing water measurements in irrigation canal systems. The results provide an engineering basis for the site selection of water-depth monitoring points that is suitable to be widely applied in the field.
format article
author Hu Xu
Zhenhua Wang
Wenhao Li
Qiuliang Wang
author_facet Hu Xu
Zhenhua Wang
Wenhao Li
Qiuliang Wang
author_sort Hu Xu
title Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model
title_short Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model
title_full Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model
title_fullStr Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model
title_full_unstemmed Assessment of Water Measurements in an Irrigation Canal System Based on Experimental Data and the CFD Model
title_sort assessment of water measurements in an irrigation canal system based on experimental data and the cfd model
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/474982c276b04cddb8d25931775c741c
work_keys_str_mv AT huxu assessmentofwatermeasurementsinanirrigationcanalsystembasedonexperimentaldataandthecfdmodel
AT zhenhuawang assessmentofwatermeasurementsinanirrigationcanalsystembasedonexperimentaldataandthecfdmodel
AT wenhaoli assessmentofwatermeasurementsinanirrigationcanalsystembasedonexperimentaldataandthecfdmodel
AT qiuliangwang assessmentofwatermeasurementsinanirrigationcanalsystembasedonexperimentaldataandthecfdmodel
_version_ 1718431343672557568