Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof

Abstract     This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season.     The numerical results of this paper showed that th...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autor principal: Ahmed A. M. Saleh
Formato: article
Lenguaje:EN
Publicado: Al-Khwarizmi College of Engineering – University of Baghdad 2014
Materias:
Acceso en línea:https://doaj.org/article/47cd7543aed24e7da49f221980fb45b2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:47cd7543aed24e7da49f221980fb45b2
record_format dspace
spelling oai:doaj.org-article:47cd7543aed24e7da49f221980fb45b22021-12-02T05:27:15ZEnergy Saving of Heat Gain by Using Buried Pipe Inside a Roof1818-11712312-0789https://doaj.org/article/47cd7543aed24e7da49f221980fb45b22014-12-01T00:00:00Zhttp://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/212https://doaj.org/toc/1818-1171https://doaj.org/toc/2312-0789 Abstract     This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season.     The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per meter of roof length is 3.0 , the ratio of pipe diameter to the wall thickness (D/W) is 0.20, and the water inlet temperature is 30°C, while the minimum ratio of reduction 24% is achieved when the number of pipes per meter, the ratio of pipe diameter to the wall thickness, and the water inlet temperature are 27, 30 and 33 °C, respectively. The results also showed that there is a very small effect of pipe centre position inside the wall on the final heat transmission. Keyword: Water pipe, Roof heat gain, Solar-air temperature. Ahmed A. M. SalehAl-Khwarizmi College of Engineering – University of BaghdadarticleWater pipe, Roof heat gain, Solar-air temperature.Chemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 11, Iss 1 (2014)
institution DOAJ
collection DOAJ
language EN
topic Water pipe, Roof heat gain, Solar-air temperature.
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle Water pipe, Roof heat gain, Solar-air temperature.
Chemical engineering
TP155-156
Engineering (General). Civil engineering (General)
TA1-2040
Ahmed A. M. Saleh
Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
description Abstract     This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season.     The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per meter of roof length is 3.0 , the ratio of pipe diameter to the wall thickness (D/W) is 0.20, and the water inlet temperature is 30°C, while the minimum ratio of reduction 24% is achieved when the number of pipes per meter, the ratio of pipe diameter to the wall thickness, and the water inlet temperature are 27, 30 and 33 °C, respectively. The results also showed that there is a very small effect of pipe centre position inside the wall on the final heat transmission. Keyword: Water pipe, Roof heat gain, Solar-air temperature.
format article
author Ahmed A. M. Saleh
author_facet Ahmed A. M. Saleh
author_sort Ahmed A. M. Saleh
title Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
title_short Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
title_full Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
title_fullStr Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
title_full_unstemmed Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
title_sort energy saving of heat gain by using buried pipe inside a roof
publisher Al-Khwarizmi College of Engineering – University of Baghdad
publishDate 2014
url https://doaj.org/article/47cd7543aed24e7da49f221980fb45b2
work_keys_str_mv AT ahmedamsaleh energysavingofheatgainbyusingburiedpipeinsidearoof
_version_ 1718400407502323712