Mechanical thrombectomy with the AVP II device

Seven-year-old male with single ventricle in the postoperative of a fenestrated extracardiac Fontan procedure. The echocardiography performed 7 days after the procedure confirmed the presence of a 20 mm pedunculated thrombus attached to the wall of the inferior vena cava (video 1 of the supplementar...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Alberto Mendoza, Marta Flores, María Dolores Herrera, Miguel Ángel Granados
Formato: article
Lenguaje:EN
ES
Publicado: Permanyer 2021
Materias:
R
Acceso en línea:https://doaj.org/article/484364e3a6224f8a8ef20d8dd03fa78d
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:484364e3a6224f8a8ef20d8dd03fa78d
record_format dspace
spelling oai:doaj.org-article:484364e3a6224f8a8ef20d8dd03fa78d2021-11-08T09:11:54ZMechanical thrombectomy with the AVP II device10.24875/RECICE.M200001822604-7322https://doaj.org/article/484364e3a6224f8a8ef20d8dd03fa78d2021-11-01T00:00:00Zhttps://recintervcardiol.org/en/index.php?option=com_content&view=article&id=546https://doaj.org/toc/2604-7322Seven-year-old male with single ventricle in the postoperative of a fenestrated extracardiac Fontan procedure. The echocardiography performed 7 days after the procedure confirmed the presence of a 20 mm pedunculated thrombus attached to the wall of the inferior vena cava (video 1 of the supplementary data). Due to the risk of systemic embolism through the Fontan fenestration, the percutaneous extraction of the thrombus was attempted using an Amplatzer Vascular Plug II (AVP II) device (Abbott, United States). A 6-Fr introducer sheath and a 10-Fr sheath were used for the catheterization of the right jugular vein and right femoral vein, respectively. The fenestration was found in the Fontan conduit using an angiography (figure 1). It was catheterized via jugular access and occluded by inflating the balloon of a 6-Fr Wedge-Pressure Catheter (Arrow, United States) to protect an eventual paradoxical embolism (figure 2). The transesophageal echocardiography performed revealed the location of the thrombus in the inferior vena cava and the diameter of the cava was measured at that level (15 mm). The introducer sheath was advanced via femoral access until it landed right underneath the insertion of the thrombus. Through this sheath a folded 16 mm AVP II device was advanced inside an 8-Fr...Alberto MendozaMarta FloresMaría Dolores HerreraMiguel Ángel GranadosPermanyerarticleMedicineRENESREC: Interventional Cardiology (English Ed.), Vol 3, Iss 4, Pp 326-327 (2021)
institution DOAJ
collection DOAJ
language EN
ES
topic Medicine
R
spellingShingle Medicine
R
Alberto Mendoza
Marta Flores
María Dolores Herrera
Miguel Ángel Granados
Mechanical thrombectomy with the AVP II device
description Seven-year-old male with single ventricle in the postoperative of a fenestrated extracardiac Fontan procedure. The echocardiography performed 7 days after the procedure confirmed the presence of a 20 mm pedunculated thrombus attached to the wall of the inferior vena cava (video 1 of the supplementary data). Due to the risk of systemic embolism through the Fontan fenestration, the percutaneous extraction of the thrombus was attempted using an Amplatzer Vascular Plug II (AVP II) device (Abbott, United States). A 6-Fr introducer sheath and a 10-Fr sheath were used for the catheterization of the right jugular vein and right femoral vein, respectively. The fenestration was found in the Fontan conduit using an angiography (figure 1). It was catheterized via jugular access and occluded by inflating the balloon of a 6-Fr Wedge-Pressure Catheter (Arrow, United States) to protect an eventual paradoxical embolism (figure 2). The transesophageal echocardiography performed revealed the location of the thrombus in the inferior vena cava and the diameter of the cava was measured at that level (15 mm). The introducer sheath was advanced via femoral access until it landed right underneath the insertion of the thrombus. Through this sheath a folded 16 mm AVP II device was advanced inside an 8-Fr...
format article
author Alberto Mendoza
Marta Flores
María Dolores Herrera
Miguel Ángel Granados
author_facet Alberto Mendoza
Marta Flores
María Dolores Herrera
Miguel Ángel Granados
author_sort Alberto Mendoza
title Mechanical thrombectomy with the AVP II device
title_short Mechanical thrombectomy with the AVP II device
title_full Mechanical thrombectomy with the AVP II device
title_fullStr Mechanical thrombectomy with the AVP II device
title_full_unstemmed Mechanical thrombectomy with the AVP II device
title_sort mechanical thrombectomy with the avp ii device
publisher Permanyer
publishDate 2021
url https://doaj.org/article/484364e3a6224f8a8ef20d8dd03fa78d
work_keys_str_mv AT albertomendoza mechanicalthrombectomywiththeavpiidevice
AT martaflores mechanicalthrombectomywiththeavpiidevice
AT mariadoloresherrera mechanicalthrombectomywiththeavpiidevice
AT miguelangelgranados mechanicalthrombectomywiththeavpiidevice
_version_ 1718442709066186752