Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS

Abstract To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups de...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Carlos Palomino-Bautista, Rubén Sánchez-Jean, David Carmona-Gonzalez, David P. Piñero, Ainhoa Molina-Martín
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/492cf1468b9741069b6900c8a1a009eb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:Abstract To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups depending on the IOL implanted: AT.LISA Tri (Carl Zeiss Meditec), FineVision (PhysIOL), PanOptix (Alcon Laboratories), Tecnis Symfony (Johnson & Johnson Vision), Miniwell (SIFI MedTech) and Tecnis Synergy (Johnson & Johnson Vision). Subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance of 0.1 logMAR. Aberrometry was also measured and the visual strehl optical transference function (VSOTF) with percentage of degradation of 90%, 80% and 60% was used to quantify objectively the DOF. Tecnis Symfony, Tecnis Synergy and Panoptix IOL groups showed better subjective and objective DOF compared to the rest of IOL groups, being these differences statistically significant differences (p < 0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being also these differences statistically significant for all groups (p < 0.001). A moderate significant correlation was found between absolute subjective criteria and VSOTF60% (r = 0.73, p < 0.05). Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation tolerance. Nevertheless, both objective and subjective measures showed a trend to a greater DOF for Tecnis Symfony and Tecnis Synergy IOLs compared to most of trifocal diffractive designs, with the exception of PanOptix.