Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS

Abstract To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups de...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Carlos Palomino-Bautista, Rubén Sánchez-Jean, David Carmona-Gonzalez, David P. Piñero, Ainhoa Molina-Martín
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/492cf1468b9741069b6900c8a1a009eb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:492cf1468b9741069b6900c8a1a009eb
record_format dspace
spelling oai:doaj.org-article:492cf1468b9741069b6900c8a1a009eb2021-12-02T14:58:14ZDepth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS10.1038/s41598-021-91654-w2045-2322https://doaj.org/article/492cf1468b9741069b6900c8a1a009eb2021-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-91654-whttps://doaj.org/toc/2045-2322Abstract To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups depending on the IOL implanted: AT.LISA Tri (Carl Zeiss Meditec), FineVision (PhysIOL), PanOptix (Alcon Laboratories), Tecnis Symfony (Johnson & Johnson Vision), Miniwell (SIFI MedTech) and Tecnis Synergy (Johnson & Johnson Vision). Subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance of 0.1 logMAR. Aberrometry was also measured and the visual strehl optical transference function (VSOTF) with percentage of degradation of 90%, 80% and 60% was used to quantify objectively the DOF. Tecnis Symfony, Tecnis Synergy and Panoptix IOL groups showed better subjective and objective DOF compared to the rest of IOL groups, being these differences statistically significant differences (p < 0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being also these differences statistically significant for all groups (p < 0.001). A moderate significant correlation was found between absolute subjective criteria and VSOTF60% (r = 0.73, p < 0.05). Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation tolerance. Nevertheless, both objective and subjective measures showed a trend to a greater DOF for Tecnis Symfony and Tecnis Synergy IOLs compared to most of trifocal diffractive designs, with the exception of PanOptix.Carlos Palomino-BautistaRubén Sánchez-JeanDavid Carmona-GonzalezDavid P. PiñeroAinhoa Molina-MartínNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Carlos Palomino-Bautista
Rubén Sánchez-Jean
David Carmona-Gonzalez
David P. Piñero
Ainhoa Molina-Martín
Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS
description Abstract To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups depending on the IOL implanted: AT.LISA Tri (Carl Zeiss Meditec), FineVision (PhysIOL), PanOptix (Alcon Laboratories), Tecnis Symfony (Johnson & Johnson Vision), Miniwell (SIFI MedTech) and Tecnis Synergy (Johnson & Johnson Vision). Subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance of 0.1 logMAR. Aberrometry was also measured and the visual strehl optical transference function (VSOTF) with percentage of degradation of 90%, 80% and 60% was used to quantify objectively the DOF. Tecnis Symfony, Tecnis Synergy and Panoptix IOL groups showed better subjective and objective DOF compared to the rest of IOL groups, being these differences statistically significant differences (p < 0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being also these differences statistically significant for all groups (p < 0.001). A moderate significant correlation was found between absolute subjective criteria and VSOTF60% (r = 0.73, p < 0.05). Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation tolerance. Nevertheless, both objective and subjective measures showed a trend to a greater DOF for Tecnis Symfony and Tecnis Synergy IOLs compared to most of trifocal diffractive designs, with the exception of PanOptix.
format article
author Carlos Palomino-Bautista
Rubén Sánchez-Jean
David Carmona-Gonzalez
David P. Piñero
Ainhoa Molina-Martín
author_facet Carlos Palomino-Bautista
Rubén Sánchez-Jean
David Carmona-Gonzalez
David P. Piñero
Ainhoa Molina-Martín
author_sort Carlos Palomino-Bautista
title Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS
title_short Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS
title_full Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS
title_fullStr Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS
title_full_unstemmed Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS
title_sort depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting iols
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/492cf1468b9741069b6900c8a1a009eb
work_keys_str_mv AT carlospalominobautista depthoffieldmeasuresinpseudophakiceyesimplantedwithdifferenttypeofpresbyopiacorrectingiols
AT rubensanchezjean depthoffieldmeasuresinpseudophakiceyesimplantedwithdifferenttypeofpresbyopiacorrectingiols
AT davidcarmonagonzalez depthoffieldmeasuresinpseudophakiceyesimplantedwithdifferenttypeofpresbyopiacorrectingiols
AT davidppinero depthoffieldmeasuresinpseudophakiceyesimplantedwithdifferenttypeofpresbyopiacorrectingiols
AT ainhoamolinamartin depthoffieldmeasuresinpseudophakiceyesimplantedwithdifferenttypeofpresbyopiacorrectingiols
_version_ 1718389323206754304