Combined use of LS-PIV and CFD for the characterization of turbulent flow in the contact chamber of ‘COSTA AZUL’ wastewater treatment plant, Carlos Paz
The Costa Azul wastewater treatment plant is situated in Carlos Paz city (Córdoba, Argentina). The treated water is discharged to the San Roque reservoir, which is the source of water for the city of Córdoba and surrounding towns. Consequently, it is of great importance to evaluate the potential imp...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
IWA Publishing
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/49558f303a7e4695bfb5dfe49c7e31e7 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:49558f303a7e4695bfb5dfe49c7e31e7 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:49558f303a7e4695bfb5dfe49c7e31e72021-11-05T17:51:29ZCombined use of LS-PIV and CFD for the characterization of turbulent flow in the contact chamber of ‘COSTA AZUL’ wastewater treatment plant, Carlos Paz1464-71411465-173410.2166/hydro.2021.024https://doaj.org/article/49558f303a7e4695bfb5dfe49c7e31e72021-09-01T00:00:00Zhttp://jh.iwaponline.com/content/23/5/1083https://doaj.org/toc/1464-7141https://doaj.org/toc/1465-1734The Costa Azul wastewater treatment plant is situated in Carlos Paz city (Córdoba, Argentina). The treated water is discharged to the San Roque reservoir, which is the source of water for the city of Córdoba and surrounding towns. Consequently, it is of great importance to evaluate the potential impact on the water quality reservoir for the preservation of public health. Currently, the WWTP lacks an accurate flow monitoring system at the last treatment: disinfection. This problem led to the development of a methodology in which experimental in-situ work and computational fluid dynamics (CFD) were applied, in a combined way, to calibrate the flow measurement system. First, large-scale particle image velocimetry (LS-PIV) was applied. The results made it possible to obtain characteristic parameters of the average flow: cross-sectional velocity profiles, recirculation and flow stagnation zones, flow discharge and characteristic parameters of the contact chamber. Second, numerical models, based on the Reynolds-average Navier–Stokes equations with the k–ε turbulent closure model were used. Based on the simulation results, it was possible to calibrate the discharge equation for a rectangular weir, and elaborate recommendations to improve the discharge measurement system and hydraulics in the area of the contact chamber curves. HIGHLIGHTS CFD simulation was used to build a head-flow curve and obtain a detail characterization of flow hydrodynamics.; Five design alternatives were modeled to improve the flow hydraulics in order to achieve the most uniform possible distribution of residence time.; Large-scale particle image velocimetry (LS-PIV) was applied to characterize of turbulent flow in prototype scale contact chamber.;Ragessi I. MatiasLeyria Rainieri GianinaGanancias FacundoGarcía C. MarceloDi Buo MelinaBalangero Bottazzi GerardoIWA Publishingarticlecfdcontact chamberls-pivturbulent flowwwtpInformation technologyT58.5-58.64Environmental technology. Sanitary engineeringTD1-1066ENJournal of Hydroinformatics, Vol 23, Iss 5, Pp 1083-1097 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
cfd contact chamber ls-piv turbulent flow wwtp Information technology T58.5-58.64 Environmental technology. Sanitary engineering TD1-1066 |
spellingShingle |
cfd contact chamber ls-piv turbulent flow wwtp Information technology T58.5-58.64 Environmental technology. Sanitary engineering TD1-1066 Ragessi I. Matias Leyria Rainieri Gianina Ganancias Facundo García C. Marcelo Di Buo Melina Balangero Bottazzi Gerardo Combined use of LS-PIV and CFD for the characterization of turbulent flow in the contact chamber of ‘COSTA AZUL’ wastewater treatment plant, Carlos Paz |
description |
The Costa Azul wastewater treatment plant is situated in Carlos Paz city (Córdoba, Argentina). The treated water is discharged to the San Roque reservoir, which is the source of water for the city of Córdoba and surrounding towns. Consequently, it is of great importance to evaluate the potential impact on the water quality reservoir for the preservation of public health. Currently, the WWTP lacks an accurate flow monitoring system at the last treatment: disinfection. This problem led to the development of a methodology in which experimental in-situ work and computational fluid dynamics (CFD) were applied, in a combined way, to calibrate the flow measurement system. First, large-scale particle image velocimetry (LS-PIV) was applied. The results made it possible to obtain characteristic parameters of the average flow: cross-sectional velocity profiles, recirculation and flow stagnation zones, flow discharge and characteristic parameters of the contact chamber. Second, numerical models, based on the Reynolds-average Navier–Stokes equations with the k–ε turbulent closure model were used. Based on the simulation results, it was possible to calibrate the discharge equation for a rectangular weir, and elaborate recommendations to improve the discharge measurement system and hydraulics in the area of the contact chamber curves. HIGHLIGHTS
CFD simulation was used to build a head-flow curve and obtain a detail characterization of flow hydrodynamics.;
Five design alternatives were modeled to improve the flow hydraulics in order to achieve the most uniform possible distribution of residence time.;
Large-scale particle image velocimetry (LS-PIV) was applied to characterize of turbulent flow in prototype scale contact chamber.; |
format |
article |
author |
Ragessi I. Matias Leyria Rainieri Gianina Ganancias Facundo García C. Marcelo Di Buo Melina Balangero Bottazzi Gerardo |
author_facet |
Ragessi I. Matias Leyria Rainieri Gianina Ganancias Facundo García C. Marcelo Di Buo Melina Balangero Bottazzi Gerardo |
author_sort |
Ragessi I. Matias |
title |
Combined use of LS-PIV and CFD for the characterization of turbulent flow in the contact chamber of ‘COSTA AZUL’ wastewater treatment plant, Carlos Paz |
title_short |
Combined use of LS-PIV and CFD for the characterization of turbulent flow in the contact chamber of ‘COSTA AZUL’ wastewater treatment plant, Carlos Paz |
title_full |
Combined use of LS-PIV and CFD for the characterization of turbulent flow in the contact chamber of ‘COSTA AZUL’ wastewater treatment plant, Carlos Paz |
title_fullStr |
Combined use of LS-PIV and CFD for the characterization of turbulent flow in the contact chamber of ‘COSTA AZUL’ wastewater treatment plant, Carlos Paz |
title_full_unstemmed |
Combined use of LS-PIV and CFD for the characterization of turbulent flow in the contact chamber of ‘COSTA AZUL’ wastewater treatment plant, Carlos Paz |
title_sort |
combined use of ls-piv and cfd for the characterization of turbulent flow in the contact chamber of ‘costa azul’ wastewater treatment plant, carlos paz |
publisher |
IWA Publishing |
publishDate |
2021 |
url |
https://doaj.org/article/49558f303a7e4695bfb5dfe49c7e31e7 |
work_keys_str_mv |
AT ragessiimatias combineduseoflspivandcfdforthecharacterizationofturbulentflowinthecontactchamberofcostaazulwastewatertreatmentplantcarlospaz AT leyriarainierigianina combineduseoflspivandcfdforthecharacterizationofturbulentflowinthecontactchamberofcostaazulwastewatertreatmentplantcarlospaz AT gananciasfacundo combineduseoflspivandcfdforthecharacterizationofturbulentflowinthecontactchamberofcostaazulwastewatertreatmentplantcarlospaz AT garciacmarcelo combineduseoflspivandcfdforthecharacterizationofturbulentflowinthecontactchamberofcostaazulwastewatertreatmentplantcarlospaz AT dibuomelina combineduseoflspivandcfdforthecharacterizationofturbulentflowinthecontactchamberofcostaazulwastewatertreatmentplantcarlospaz AT balangerobottazzigerardo combineduseoflspivandcfdforthecharacterizationofturbulentflowinthecontactchamberofcostaazulwastewatertreatmentplantcarlospaz |
_version_ |
1718444099684532224 |