High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients

Tomris Sengor, Sevda Aydin Kurna, Suat Aki, Yelda ÖzkurtFatih Sultan Mehmet Training and Research Hospital, Istanbul, TurkeyBackground: The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of c...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Tomris Sengor, Sevda Aydin Kurna, Suat Aki, et al
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2011
Materias:
Acceso en línea:https://doaj.org/article/49a99e6e9ab64d08ae5d759df0d3b2ec
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:49a99e6e9ab64d08ae5d759df0d3b2ec
record_format dspace
spelling oai:doaj.org-article:49a99e6e9ab64d08ae5d759df0d3b2ec2021-12-02T00:34:53ZHigh Dk piggyback contact lens system for contact lens-intolerant keratoconus patients1177-54671177-5483https://doaj.org/article/49a99e6e9ab64d08ae5d759df0d3b2ec2011-03-01T00:00:00Zhttp://www.dovepress.com/high-dk-piggyback-contact-lens-system-for-contact-lens-intolerant-kera-a6553https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Tomris Sengor, Sevda Aydin Kurna, Suat Aki, Yelda ÖzkurtFatih Sultan Mehmet Training and Research Hospital, Istanbul, TurkeyBackground: The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of contact lens intolerant keratoconus patients.Methods: Sixteen patients (29 eyes) who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen transmissibility or Dk/t = 150 units) and fluorosilicone methacrylate copolymer (Dk/t = 100 units) lenses were chosen as the PBCL systems. The clinical examinations included visual acuity and corneal observation by biomicroscopy, keratometer reading, and fluorescein staining before and after fitting the PBCL system.Results: Indications for using PBCL system were: lens stabilization and comfort, improving comfort, and adding protection to the cone. Visual acuities increased significantly in all of the patients compared with spectacles (P = 0). Improvement in visual acuity compared with rigid lenses alone was recorded in 89.7% of eyes and no alteration of the visual acuity was observed in 10.3% of the eyes. Wearing time of PBCL systems for most of the patients was limited time (mean 6 months, range 3–12 months); thereafter they tolerated rigid lenses alone except for 2 patients.Conclusion: The PBCL system is a safe and effective method to provide centering and corneal protection against mechanical trauma by the rigid lenses for keratoconus patients and may increase contact lens tolerance.Keywords: piggyback contact lens, keratoconus, irregular astigmatism Tomris SengorSevda Aydin KurnaSuat Akiet alDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2011, Iss default, Pp 331-335 (2011)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Tomris Sengor
Sevda Aydin Kurna
Suat Aki
et al
High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients
description Tomris Sengor, Sevda Aydin Kurna, Suat Aki, Yelda ÖzkurtFatih Sultan Mehmet Training and Research Hospital, Istanbul, TurkeyBackground: The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of contact lens intolerant keratoconus patients.Methods: Sixteen patients (29 eyes) who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen transmissibility or Dk/t = 150 units) and fluorosilicone methacrylate copolymer (Dk/t = 100 units) lenses were chosen as the PBCL systems. The clinical examinations included visual acuity and corneal observation by biomicroscopy, keratometer reading, and fluorescein staining before and after fitting the PBCL system.Results: Indications for using PBCL system were: lens stabilization and comfort, improving comfort, and adding protection to the cone. Visual acuities increased significantly in all of the patients compared with spectacles (P = 0). Improvement in visual acuity compared with rigid lenses alone was recorded in 89.7% of eyes and no alteration of the visual acuity was observed in 10.3% of the eyes. Wearing time of PBCL systems for most of the patients was limited time (mean 6 months, range 3–12 months); thereafter they tolerated rigid lenses alone except for 2 patients.Conclusion: The PBCL system is a safe and effective method to provide centering and corneal protection against mechanical trauma by the rigid lenses for keratoconus patients and may increase contact lens tolerance.Keywords: piggyback contact lens, keratoconus, irregular astigmatism
format article
author Tomris Sengor
Sevda Aydin Kurna
Suat Aki
et al
author_facet Tomris Sengor
Sevda Aydin Kurna
Suat Aki
et al
author_sort Tomris Sengor
title High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients
title_short High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients
title_full High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients
title_fullStr High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients
title_full_unstemmed High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients
title_sort high dk piggyback contact lens system for contact lens-intolerant keratoconus patients
publisher Dove Medical Press
publishDate 2011
url https://doaj.org/article/49a99e6e9ab64d08ae5d759df0d3b2ec
work_keys_str_mv AT tomrissengor highdkpiggybackcontactlenssystemforcontactlensintolerantkeratoconuspatients
AT sevdaaydinkurna highdkpiggybackcontactlenssystemforcontactlensintolerantkeratoconuspatients
AT suataki highdkpiggybackcontactlenssystemforcontactlensintolerantkeratoconuspatients
AT etal highdkpiggybackcontactlenssystemforcontactlensintolerantkeratoconuspatients
_version_ 1718403613290659840