Comparing the mechanical strength of wooden chairs constructed using two patterns and mortise and tenon and dowel joints

Member joints and furniture designs are very important in the production of these elements and the strength of the structure is affected by both the joints and designs. The performance of the chairs made from poplar wood against the front to back load test and also, mechanical strength of mortise an...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ali Bayatkashkoli, Mehdi Jamshedzadeh
Formato: article
Lenguaje:FA
Publicado: Regional Information Center for Science and Technology (RICeST) 2014
Materias:
Acceso en línea:https://doaj.org/article/4a5cf7f05fda435ca02a9d2b77af490c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:4a5cf7f05fda435ca02a9d2b77af490c
record_format dspace
spelling oai:doaj.org-article:4a5cf7f05fda435ca02a9d2b77af490c2021-12-02T09:11:26ZComparing the mechanical strength of wooden chairs constructed using two patterns and mortise and tenon and dowel joints1735-09132383-112X10.22092/ijwpr.2014.4930https://doaj.org/article/4a5cf7f05fda435ca02a9d2b77af490c2014-03-01T00:00:00Zhttp://ijwpr.areeo.ac.ir/article_4930_dae2c5bc48741eae0453d51428eb8fcc.pdfhttps://doaj.org/toc/1735-0913https://doaj.org/toc/2383-112XMember joints and furniture designs are very important in the production of these elements and the strength of the structure is affected by both the joints and designs. The performance of the chairs made from poplar wood against the front to back load test and also, mechanical strength of mortise and tenon and dowel joints were evaluated and compared. Two types common wooden chairs having side stretcher or without side stretcher, and also the chairs structured by common joints and poly vinyl acetate (PVA) adhesive are evaluated and their maximum strength were measured. The results showed that treatments and intercept treatments were statistically significant with the 95% confidence. Duncan analysis for comparison of the averages showed that maximum load of different treatments can be classified into four category; A; Pattern of side stretcher with mortise and tenon joint (984.5 N), B; Pattern of side stretcher with dowel joint (892.4 N), C; Pattern without side stretcher with mortise and tenon joint (303.3 N), D;  Pattern without side stretcher with dowel joint (260.2 N). Since, all treatments showed statistically significant differences, it can be conclude that the maximum strength of the chairs is significantly influenced by the pattern of side stretcher and the other factor is the mortise and tenon joint.Ali BayatkashkoliMehdi JamshedzadehRegional Information Center for Science and Technology (RICeST)articleMaximum strengthstructure patternjoint of mortise and tenondowel jointsForestrySD1-669.5FAتحقیقات علوم چوب و کاغذ ایران, Vol 29, Iss 1, Pp 67-78 (2014)
institution DOAJ
collection DOAJ
language FA
topic Maximum strength
structure pattern
joint of mortise and tenon
dowel joints
Forestry
SD1-669.5
spellingShingle Maximum strength
structure pattern
joint of mortise and tenon
dowel joints
Forestry
SD1-669.5
Ali Bayatkashkoli
Mehdi Jamshedzadeh
Comparing the mechanical strength of wooden chairs constructed using two patterns and mortise and tenon and dowel joints
description Member joints and furniture designs are very important in the production of these elements and the strength of the structure is affected by both the joints and designs. The performance of the chairs made from poplar wood against the front to back load test and also, mechanical strength of mortise and tenon and dowel joints were evaluated and compared. Two types common wooden chairs having side stretcher or without side stretcher, and also the chairs structured by common joints and poly vinyl acetate (PVA) adhesive are evaluated and their maximum strength were measured. The results showed that treatments and intercept treatments were statistically significant with the 95% confidence. Duncan analysis for comparison of the averages showed that maximum load of different treatments can be classified into four category; A; Pattern of side stretcher with mortise and tenon joint (984.5 N), B; Pattern of side stretcher with dowel joint (892.4 N), C; Pattern without side stretcher with mortise and tenon joint (303.3 N), D;  Pattern without side stretcher with dowel joint (260.2 N). Since, all treatments showed statistically significant differences, it can be conclude that the maximum strength of the chairs is significantly influenced by the pattern of side stretcher and the other factor is the mortise and tenon joint.
format article
author Ali Bayatkashkoli
Mehdi Jamshedzadeh
author_facet Ali Bayatkashkoli
Mehdi Jamshedzadeh
author_sort Ali Bayatkashkoli
title Comparing the mechanical strength of wooden chairs constructed using two patterns and mortise and tenon and dowel joints
title_short Comparing the mechanical strength of wooden chairs constructed using two patterns and mortise and tenon and dowel joints
title_full Comparing the mechanical strength of wooden chairs constructed using two patterns and mortise and tenon and dowel joints
title_fullStr Comparing the mechanical strength of wooden chairs constructed using two patterns and mortise and tenon and dowel joints
title_full_unstemmed Comparing the mechanical strength of wooden chairs constructed using two patterns and mortise and tenon and dowel joints
title_sort comparing the mechanical strength of wooden chairs constructed using two patterns and mortise and tenon and dowel joints
publisher Regional Information Center for Science and Technology (RICeST)
publishDate 2014
url https://doaj.org/article/4a5cf7f05fda435ca02a9d2b77af490c
work_keys_str_mv AT alibayatkashkoli comparingthemechanicalstrengthofwoodenchairsconstructedusingtwopatternsandmortiseandtenonanddoweljoints
AT mehdijamshedzadeh comparingthemechanicalstrengthofwoodenchairsconstructedusingtwopatternsandmortiseandtenonanddoweljoints
_version_ 1718398182604406784