Sustainable operation analysis of the mining industry power supply system
The paper presents an analysis of operating currents and torques during self-starting of motors with a voltage of 6 kV for cases of short circuit in the head feeders from the main step-down substation and in the feeders to the most distant substations of mining enterprises. For the network under con...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN FR |
Publicado: |
EDP Sciences
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/4a6704f2fcac479397abf6f210c548e5 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:4a6704f2fcac479397abf6f210c548e5 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:4a6704f2fcac479397abf6f210c548e52021-12-02T17:12:02ZSustainable operation analysis of the mining industry power supply system2267-124210.1051/e3sconf/202132600016https://doaj.org/article/4a6704f2fcac479397abf6f210c548e52021-01-01T00:00:00Zhttps://www.e3s-conferences.org/articles/e3sconf/pdf/2021/102/e3sconf_ipdme2021_00016.pdfhttps://doaj.org/toc/2267-1242The paper presents an analysis of operating currents and torques during self-starting of motors with a voltage of 6 kV for cases of short circuit in the head feeders from the main step-down substation and in the feeders to the most distant substations of mining enterprises. For the network under consideration, the characteristic modes are: short circuit on the buses of shop substations. For the mining industry when selfstarting asynchronous motors with a squirrel-cage rotor and synchronous motors with asynchronous startup, the current multiplicity will be determined by the duration of the power failure (run-down duration). It has been established that the acceleration of motors during self-start will be somewhat slower than the usual start, since self-start begins at a speed of 0.89–0.94 of the synchronous speed and a resistance torque is equal to 0.65–0.75 of the maximum motor torque. The self-starting time of the motors is from 9 s to 42 s. To ensure self-starting conditions in the most severe modes in mountain conditions, it is necessary to make changes to the protection settings presented in the work.Klyuev RomanTekiev MaratSilaev VadimBosikov IgorGavrina OksanaEDP SciencesarticleEnvironmental sciencesGE1-350ENFRE3S Web of Conferences, Vol 326, p 00016 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN FR |
topic |
Environmental sciences GE1-350 |
spellingShingle |
Environmental sciences GE1-350 Klyuev Roman Tekiev Marat Silaev Vadim Bosikov Igor Gavrina Oksana Sustainable operation analysis of the mining industry power supply system |
description |
The paper presents an analysis of operating currents and torques during self-starting of motors with a voltage of 6 kV for cases of short circuit in the head feeders from the main step-down substation and in the feeders to the most distant substations of mining enterprises. For the network under consideration, the characteristic modes are: short circuit on the buses of shop substations. For the mining industry when selfstarting asynchronous motors with a squirrel-cage rotor and synchronous motors with asynchronous startup, the current multiplicity will be determined by the duration of the power failure (run-down duration). It has been established that the acceleration of motors during self-start will be somewhat slower than the usual start, since self-start begins at a speed of 0.89–0.94 of the synchronous speed and a resistance torque is equal to 0.65–0.75 of the maximum motor torque. The self-starting time of the motors is from 9 s to 42 s. To ensure self-starting conditions in the most severe modes in mountain conditions, it is necessary to make changes to the protection settings presented in the work. |
format |
article |
author |
Klyuev Roman Tekiev Marat Silaev Vadim Bosikov Igor Gavrina Oksana |
author_facet |
Klyuev Roman Tekiev Marat Silaev Vadim Bosikov Igor Gavrina Oksana |
author_sort |
Klyuev Roman |
title |
Sustainable operation analysis of the mining industry power supply system |
title_short |
Sustainable operation analysis of the mining industry power supply system |
title_full |
Sustainable operation analysis of the mining industry power supply system |
title_fullStr |
Sustainable operation analysis of the mining industry power supply system |
title_full_unstemmed |
Sustainable operation analysis of the mining industry power supply system |
title_sort |
sustainable operation analysis of the mining industry power supply system |
publisher |
EDP Sciences |
publishDate |
2021 |
url |
https://doaj.org/article/4a6704f2fcac479397abf6f210c548e5 |
work_keys_str_mv |
AT klyuevroman sustainableoperationanalysisoftheminingindustrypowersupplysystem AT tekievmarat sustainableoperationanalysisoftheminingindustrypowersupplysystem AT silaevvadim sustainableoperationanalysisoftheminingindustrypowersupplysystem AT bosikovigor sustainableoperationanalysisoftheminingindustrypowersupplysystem AT gavrinaoksana sustainableoperationanalysisoftheminingindustrypowersupplysystem |
_version_ |
1718381431749607424 |