Determination of Glucose with Cellulose Acetate/Glucose Oxidase Modified Carbon Paste Electrodes

An amperometric biosensor for glucose determination was developed using a carbon paste electrode (CPE) modified with cellulose acetate (CA)/glucose oxidase (GOx) bilayer membrane through the electrostatic interaction between them. The CA membrane was used as matrix for enzyme immobilization via micr...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Rochmad Kris Sanjaya, Datin An Nisa Sukmawati, Nurul Ismillayli, Dhony Hermanto
Formato: article
Lenguaje:EN
ID
Publicado: Jenderal Soedirman University 2021
Materias:
Acceso en línea:https://doaj.org/article/4ae056386991483b8ef3ef2a613d2580
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:4ae056386991483b8ef3ef2a613d2580
record_format dspace
spelling oai:doaj.org-article:4ae056386991483b8ef3ef2a613d25802021-11-22T01:13:54ZDetermination of Glucose with Cellulose Acetate/Glucose Oxidase Modified Carbon Paste Electrodes1907-97612503-031010.20884/1.jm.2021.16.3.679https://doaj.org/article/4ae056386991483b8ef3ef2a613d25802021-11-01T00:00:00Zhttps://ojs.jmolekul.com/ojs/index.php/jm/article/view/679https://doaj.org/toc/1907-9761https://doaj.org/toc/2503-0310An amperometric biosensor for glucose determination was developed using a carbon paste electrode (CPE) modified with cellulose acetate (CA)/glucose oxidase (GOx) bilayer membrane through the electrostatic interaction between them. The CA membrane was used as matrix for enzyme immobilization via microencapsulation technique, is enzyme placed between two membranes. CA/GOx membrane was attached to CPE surface containing ferrocene (Fc). By using proposed amperometric biosensor, glucose concentration was determined as well as its characteristic. The modified Fc–graphite electrode with CA/GOx bilayer membrane for glucose had optimum measurement conditions at work emf of 874 mV, CA concentration of 10% and amount Fc of 0.021 mg. The biosensor showed good performance at glucose concentration range of 0.05–3 mM and limit of detection was 0.024 mM. Proposed biosensor has good reproducibility with relative standard deviation (RSD) was less than 5% up to 7 times use (in the defined condition 4 ˚C). Glucose measurement result in human serum of diabetes mellitus patients showed conformity with result of reference method, MediSense Optium glucose test kit.Rochmad Kris SanjayaDatin An Nisa SukmawatiNurul IsmillayliDhony HermantoJenderal Soedirman UniversityarticleChemistryQD1-999ENIDMolekul, Vol 16, Iss 3, Pp 176-183 (2021)
institution DOAJ
collection DOAJ
language EN
ID
topic Chemistry
QD1-999
spellingShingle Chemistry
QD1-999
Rochmad Kris Sanjaya
Datin An Nisa Sukmawati
Nurul Ismillayli
Dhony Hermanto
Determination of Glucose with Cellulose Acetate/Glucose Oxidase Modified Carbon Paste Electrodes
description An amperometric biosensor for glucose determination was developed using a carbon paste electrode (CPE) modified with cellulose acetate (CA)/glucose oxidase (GOx) bilayer membrane through the electrostatic interaction between them. The CA membrane was used as matrix for enzyme immobilization via microencapsulation technique, is enzyme placed between two membranes. CA/GOx membrane was attached to CPE surface containing ferrocene (Fc). By using proposed amperometric biosensor, glucose concentration was determined as well as its characteristic. The modified Fc–graphite electrode with CA/GOx bilayer membrane for glucose had optimum measurement conditions at work emf of 874 mV, CA concentration of 10% and amount Fc of 0.021 mg. The biosensor showed good performance at glucose concentration range of 0.05–3 mM and limit of detection was 0.024 mM. Proposed biosensor has good reproducibility with relative standard deviation (RSD) was less than 5% up to 7 times use (in the defined condition 4 ˚C). Glucose measurement result in human serum of diabetes mellitus patients showed conformity with result of reference method, MediSense Optium glucose test kit.
format article
author Rochmad Kris Sanjaya
Datin An Nisa Sukmawati
Nurul Ismillayli
Dhony Hermanto
author_facet Rochmad Kris Sanjaya
Datin An Nisa Sukmawati
Nurul Ismillayli
Dhony Hermanto
author_sort Rochmad Kris Sanjaya
title Determination of Glucose with Cellulose Acetate/Glucose Oxidase Modified Carbon Paste Electrodes
title_short Determination of Glucose with Cellulose Acetate/Glucose Oxidase Modified Carbon Paste Electrodes
title_full Determination of Glucose with Cellulose Acetate/Glucose Oxidase Modified Carbon Paste Electrodes
title_fullStr Determination of Glucose with Cellulose Acetate/Glucose Oxidase Modified Carbon Paste Electrodes
title_full_unstemmed Determination of Glucose with Cellulose Acetate/Glucose Oxidase Modified Carbon Paste Electrodes
title_sort determination of glucose with cellulose acetate/glucose oxidase modified carbon paste electrodes
publisher Jenderal Soedirman University
publishDate 2021
url https://doaj.org/article/4ae056386991483b8ef3ef2a613d2580
work_keys_str_mv AT rochmadkrissanjaya determinationofglucosewithcelluloseacetateglucoseoxidasemodifiedcarbonpasteelectrodes
AT datinannisasukmawati determinationofglucosewithcelluloseacetateglucoseoxidasemodifiedcarbonpasteelectrodes
AT nurulismillayli determinationofglucosewithcelluloseacetateglucoseoxidasemodifiedcarbonpasteelectrodes
AT dhonyhermanto determinationofglucosewithcelluloseacetateglucoseoxidasemodifiedcarbonpasteelectrodes
_version_ 1718418280083881984