Repair of local damages to precast prestressed slab elements at a parking garage
The durability of precast structures often depends on quality of execution of the connections between the structural elements. Essential also is their design and proper exploitation. This paper focuses on the magnitude of damages as well as repair methods used for a precast slab, which consists of p...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN FR |
Publicado: |
EDP Sciences
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/4c99a5f6fbd64996a546531eed75f5df |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:4c99a5f6fbd64996a546531eed75f5df |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:4c99a5f6fbd64996a546531eed75f5df2021-12-02T17:13:46ZRepair of local damages to precast prestressed slab elements at a parking garage2261-236X10.1051/matecconf/202134904013https://doaj.org/article/4c99a5f6fbd64996a546531eed75f5df2021-01-01T00:00:00Zhttps://www.matec-conferences.org/articles/matecconf/pdf/2021/18/matecconf_iceaf2021_04013.pdfhttps://doaj.org/toc/2261-236XThe durability of precast structures often depends on quality of execution of the connections between the structural elements. Essential also is their design and proper exploitation. This paper focuses on the magnitude of damages as well as repair methods used for a precast slab, which consists of prestressed double T slab elements supported on prestressed inverted T girders. It was found that during execution, the girders were forced to fit dowel bars, which resulted in their initial deformation. Moreover, those connection zones were subjected to unpredicted loading coming from delivery trucks. It resulted in crushing of the elastomeric bearings, uncontrolled rotation of double T precast elements, and further deformation of dowel bars. Numerous cracks, splits, concrete spalling, surface rust stains, and efflorescence were observed. To prevent failure, a project for repair was developed. The slab was lifted with the use of a jacks to provide necessary space for work. Damaged dowel bars and elastomeric bearings were removed. The concrete surface of double T beams and the inverted T girder was cleaned, refilled, prepared, and strengthened with FRP wraps. Additionally, steel angles were used to protect the edges of the inverted T girder.Lutomirska MartaLutomirski TomaszSakowski ArturEDP SciencesarticleEngineering (General). Civil engineering (General)TA1-2040ENFRMATEC Web of Conferences, Vol 349, p 04013 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN FR |
topic |
Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
Engineering (General). Civil engineering (General) TA1-2040 Lutomirska Marta Lutomirski Tomasz Sakowski Artur Repair of local damages to precast prestressed slab elements at a parking garage |
description |
The durability of precast structures often depends on quality of execution of the connections between the structural elements. Essential also is their design and proper exploitation. This paper focuses on the magnitude of damages as well as repair methods used for a precast slab, which consists of prestressed double T slab elements supported on prestressed inverted T girders. It was found that during execution, the girders were forced to fit dowel bars, which resulted in their initial deformation. Moreover, those connection zones were subjected to unpredicted loading coming from delivery trucks. It resulted in crushing of the elastomeric bearings, uncontrolled rotation of double T precast elements, and further deformation of dowel bars. Numerous cracks, splits, concrete spalling, surface rust stains, and efflorescence were observed. To prevent failure, a project for repair was developed. The slab was lifted with the use of a jacks to provide necessary space for work. Damaged dowel bars and elastomeric bearings were removed. The concrete surface of double T beams and the inverted T girder was cleaned, refilled, prepared, and strengthened with FRP wraps. Additionally, steel angles were used to protect the edges of the inverted T girder. |
format |
article |
author |
Lutomirska Marta Lutomirski Tomasz Sakowski Artur |
author_facet |
Lutomirska Marta Lutomirski Tomasz Sakowski Artur |
author_sort |
Lutomirska Marta |
title |
Repair of local damages to precast prestressed slab elements at a parking garage |
title_short |
Repair of local damages to precast prestressed slab elements at a parking garage |
title_full |
Repair of local damages to precast prestressed slab elements at a parking garage |
title_fullStr |
Repair of local damages to precast prestressed slab elements at a parking garage |
title_full_unstemmed |
Repair of local damages to precast prestressed slab elements at a parking garage |
title_sort |
repair of local damages to precast prestressed slab elements at a parking garage |
publisher |
EDP Sciences |
publishDate |
2021 |
url |
https://doaj.org/article/4c99a5f6fbd64996a546531eed75f5df |
work_keys_str_mv |
AT lutomirskamarta repairoflocaldamagestoprecastprestressedslabelementsataparkinggarage AT lutomirskitomasz repairoflocaldamagestoprecastprestressedslabelementsataparkinggarage AT sakowskiartur repairoflocaldamagestoprecastprestressedslabelementsataparkinggarage |
_version_ |
1718381316729208832 |