Refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes

Paul J Dougherty,1,2 Taylor Priver1 1Dougherty Laser Vision, Westlake Village, CA, USA; 2Jules Stein Eye Institute at the David Geffen School of Medicine at UCLA, Los Angeles, CA, USA Purpose: To evaluate visual and refractive outcomes and safety of implantable collamer lens (ICL) implantation in...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Dougherty PJ, Priver T
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2017
Materias:
ICL
Acceso en línea:https://doaj.org/article/4cb272e06d1f48b885573abda62ce0f8
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:4cb272e06d1f48b885573abda62ce0f8
record_format dspace
spelling oai:doaj.org-article:4cb272e06d1f48b885573abda62ce0f82021-12-02T00:13:28ZRefractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes1177-5483https://doaj.org/article/4cb272e06d1f48b885573abda62ce0f82017-01-01T00:00:00Zhttps://www.dovepress.com/refractive-outcomes-and-safety-of-the-implantable-collamer-lens-in-you-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Paul J Dougherty,1,2 Taylor Priver1 1Dougherty Laser Vision, Westlake Village, CA, USA; 2Jules Stein Eye Institute at the David Geffen School of Medicine at UCLA, Los Angeles, CA, USA Purpose: To evaluate visual and refractive outcomes and safety of implantable collamer lens (ICL) implantation in low-to-moderate myopia. Setting: Private Practice – Dougherty Laser Vision, Westlake Village, CA, USA. Methods: A chart review was performed in 56 (104 eyes) consecutive patients who underwent implantation of the Visian ICL V4 model. Inclusion criteria were age between 21 and 40 years, spherical equivalent between -3.00 D and -10.00 D, and cylinder up to -5 D. Data on visual acuity, refraction, and complications were collected. Results: The mean time to the last postoperative visit was 13.1±14.0 months (range, 2 to 50 months). The mean preoperative spherical equivalent was -6.96±1.60 D and the mean preoperative cylinder was -1.03±0.88 D. The mean preoperative corrected distance visual acuity (CDVA) was 20/20 (range, 20/15 to 20/80) that remained unchanged at last postoperative visit. At the last postoperative visit, the spherical equivalent was -0.08±0.01 D and the cylinder was 0.29±0.71 D. Comparison of postoperative uncorrected distance visual acuity (UCDVA) to preoperative CDVA indicated that 27 eyes (26%) had better postoperative UCDVA and 61 eyes (59%) had UDVA equivalent to the preoperative CDVA. Postoperatively, 4 eyes lost 1 line of CDVA and no eyes lost >1 line of CDVA. There were 32 eyes that gained at least ≥1 of CDVA. There were no intraoperative complications. Postoperatively, 3 patients (6 eyes) had dry eye, and 1 patient complained of nighttime halos in 1 eye. At the last postoperative visit, there were no eyes with lens opacity or glaucoma. Conclusion: ICL implantation for low and moderate myopia up to -10 D in patients up to 40 years of age was safe, accurate, and efficacious. ICL implantation may be a good alternative to laser in situ keratomileusis for young myopes less than -10.00 D. Keywords: ICL, low myopia, Costa Rica, Dougherty Laser VisionDougherty PJPriver TDove Medical PressarticleICLlow myopiacosta ricaDougherty Laser VisionOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 11, Pp 273-277 (2017)
institution DOAJ
collection DOAJ
language EN
topic ICL
low myopia
costa rica
Dougherty Laser Vision
Ophthalmology
RE1-994
spellingShingle ICL
low myopia
costa rica
Dougherty Laser Vision
Ophthalmology
RE1-994
Dougherty PJ
Priver T
Refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes
description Paul J Dougherty,1,2 Taylor Priver1 1Dougherty Laser Vision, Westlake Village, CA, USA; 2Jules Stein Eye Institute at the David Geffen School of Medicine at UCLA, Los Angeles, CA, USA Purpose: To evaluate visual and refractive outcomes and safety of implantable collamer lens (ICL) implantation in low-to-moderate myopia. Setting: Private Practice – Dougherty Laser Vision, Westlake Village, CA, USA. Methods: A chart review was performed in 56 (104 eyes) consecutive patients who underwent implantation of the Visian ICL V4 model. Inclusion criteria were age between 21 and 40 years, spherical equivalent between -3.00 D and -10.00 D, and cylinder up to -5 D. Data on visual acuity, refraction, and complications were collected. Results: The mean time to the last postoperative visit was 13.1±14.0 months (range, 2 to 50 months). The mean preoperative spherical equivalent was -6.96±1.60 D and the mean preoperative cylinder was -1.03±0.88 D. The mean preoperative corrected distance visual acuity (CDVA) was 20/20 (range, 20/15 to 20/80) that remained unchanged at last postoperative visit. At the last postoperative visit, the spherical equivalent was -0.08±0.01 D and the cylinder was 0.29±0.71 D. Comparison of postoperative uncorrected distance visual acuity (UCDVA) to preoperative CDVA indicated that 27 eyes (26%) had better postoperative UCDVA and 61 eyes (59%) had UDVA equivalent to the preoperative CDVA. Postoperatively, 4 eyes lost 1 line of CDVA and no eyes lost >1 line of CDVA. There were 32 eyes that gained at least ≥1 of CDVA. There were no intraoperative complications. Postoperatively, 3 patients (6 eyes) had dry eye, and 1 patient complained of nighttime halos in 1 eye. At the last postoperative visit, there were no eyes with lens opacity or glaucoma. Conclusion: ICL implantation for low and moderate myopia up to -10 D in patients up to 40 years of age was safe, accurate, and efficacious. ICL implantation may be a good alternative to laser in situ keratomileusis for young myopes less than -10.00 D. Keywords: ICL, low myopia, Costa Rica, Dougherty Laser Vision
format article
author Dougherty PJ
Priver T
author_facet Dougherty PJ
Priver T
author_sort Dougherty PJ
title Refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes
title_short Refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes
title_full Refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes
title_fullStr Refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes
title_full_unstemmed Refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes
title_sort refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes
publisher Dove Medical Press
publishDate 2017
url https://doaj.org/article/4cb272e06d1f48b885573abda62ce0f8
work_keys_str_mv AT doughertypj refractiveoutcomesandsafetyoftheimplantablecollamerlensinyounglowtomoderatemyopes
AT privert refractiveoutcomesandsafetyoftheimplantablecollamerlensinyounglowtomoderatemyopes
_version_ 1718403863506059264