ANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT WITH A COMMON MODULATOR PHASE CONNECTION UNDER OPERATION TO AN INDUCTION MOTORS SITE
By means of a mathematical experiment, electromagnetic and electromechanical processes in an independent electric power supply system based on an asynchronized generator with a three-phase modulated exciter are investigated. The processes are analyzed to specify the working capacity of the power sup...
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN RU UK |
Publicado: |
National Technical University "Kharkiv Polytechnic Institute"
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/4cf37956d96c4711abdcd780c2439452 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:4cf37956d96c4711abdcd780c2439452 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:4cf37956d96c4711abdcd780c24394522021-12-02T16:33:01ZANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT WITH A COMMON MODULATOR PHASE CONNECTION UNDER OPERATION TO AN INDUCTION MOTORS SITE 2074-272Xhttps://doaj.org/article/4cf37956d96c4711abdcd780c24394522013-04-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/12939/10812https://doaj.org/toc/2074-272XBy means of a mathematical experiment, electromagnetic and electromechanical processes in an independent electric power supply system based on an asynchronized generator with a three-phase modulated exciter are investigated. The processes are analyzed to specify the working capacity of the power supply system during its operation to an induction motors site. Regularities of the electromagnetic and electromechanical processes behavior versus load intensity and the switch control system parameters are identified. K.M. VasylivNational Technical University "Kharkiv Polytechnic Institute"articleasynchronized generatornoncontact modulated exciterindependent power supply systemcommutatorinduction motorelectromagnetic and electromechanical processesmathematical experimentElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 2, Pp 23-28 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN RU UK |
topic |
asynchronized generator noncontact modulated exciter independent power supply system commutator induction motor electromagnetic and electromechanical processes mathematical experiment Electrical engineering. Electronics. Nuclear engineering TK1-9971 |
spellingShingle |
asynchronized generator noncontact modulated exciter independent power supply system commutator induction motor electromagnetic and electromechanical processes mathematical experiment Electrical engineering. Electronics. Nuclear engineering TK1-9971 K.M. Vasyliv ANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT WITH A COMMON MODULATOR PHASE CONNECTION UNDER OPERATION TO AN INDUCTION MOTORS SITE |
description |
By means of a mathematical experiment, electromagnetic and electromechanical processes in an independent electric power supply system based on an asynchronized generator with a three-phase modulated exciter are investigated. The processes are analyzed to specify the working capacity of the power supply system during its operation to an induction motors site. Regularities of the electromagnetic and electromechanical processes behavior versus load intensity and the switch control system parameters are identified. |
format |
article |
author |
K.M. Vasyliv |
author_facet |
K.M. Vasyliv |
author_sort |
K.M. Vasyliv |
title |
ANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT WITH A COMMON MODULATOR PHASE CONNECTION UNDER OPERATION TO AN INDUCTION MOTORS SITE |
title_short |
ANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT WITH A COMMON MODULATOR PHASE CONNECTION UNDER OPERATION TO AN INDUCTION MOTORS SITE |
title_full |
ANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT WITH A COMMON MODULATOR PHASE CONNECTION UNDER OPERATION TO AN INDUCTION MOTORS SITE |
title_fullStr |
ANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT WITH A COMMON MODULATOR PHASE CONNECTION UNDER OPERATION TO AN INDUCTION MOTORS SITE |
title_full_unstemmed |
ANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT WITH A COMMON MODULATOR PHASE CONNECTION UNDER OPERATION TO AN INDUCTION MOTORS SITE |
title_sort |
analysis of processes in an independent generator with a noncontact cascade three-phase modulated exciter via a star-connected circuit with a common modulator phase connection under operation to an induction motors site |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
publishDate |
2013 |
url |
https://doaj.org/article/4cf37956d96c4711abdcd780c2439452 |
work_keys_str_mv |
AT kmvasyliv analysisofprocessesinanindependentgeneratorwithanoncontactcascadethreephasemodulatedexciterviaastarconnectedcircuitwithacommonmodulatorphaseconnectionunderoperationtoaninductionmotorssite |
_version_ |
1718383750501367808 |