A prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation

Gernot IW Duncker, Anna C Sasse, Tobias Duncker Institute of Ophthalmology, Halle, GermanyCorrespondence: Tobias DunckerInstitute of Ophthalmology, Rathenauplatz 12, 06114 Halle, GermanyEmail tobias.duncker@augenheilkunde.dePurpose: To assess whether residual refractive error after in-the-bag multif...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Duncker GIW, Sasse AC, Duncker T
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
icl
Acceso en línea:https://doaj.org/article/4dc88f7293414ae6925fac2168fc7fd9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:4dc88f7293414ae6925fac2168fc7fd9
record_format dspace
spelling oai:doaj.org-article:4dc88f7293414ae6925fac2168fc7fd92021-12-02T02:16:51ZA prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation1177-5483https://doaj.org/article/4dc88f7293414ae6925fac2168fc7fd92019-09-01T00:00:00Zhttps://www.dovepress.com/a-prospective-pilot-study-using-a-low-power-piggy-back-toric-implantab-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Gernot IW Duncker, Anna C Sasse, Tobias Duncker Institute of Ophthalmology, Halle, GermanyCorrespondence: Tobias DunckerInstitute of Ophthalmology, Rathenauplatz 12, 06114 Halle, GermanyEmail tobias.duncker@augenheilkunde.dePurpose: To assess whether residual refractive error after in-the-bag multifocal intraocular lens (mIOL) implantation can efficaciously and safely be corrected with a piggy-back low power Visian Toric Implantable Collamer Lens® (VTICL, STAAR Surgical) placed in the ciliary sulcus.Patients and methods: Twenty-four eyes of 23 patients (mean age: 57.5 years) with diminished uncorrected distance visual acuity (UDVA) of ≥2 lines due to residual refractive error after mIOL implantation were included in the study. VTICL size was calculated using the standard STAAR Visian ICL calculation software for phakic eyes. Postoperative study visits (1 day, 1 week, 3 months and 6 months after VTICL implantation) included UDVA, corrected distance visual acuity (CDVA), VTICL axis alignment, vault (space between mIOL and VTICL), IOP and documentation of adverse events.Results: At 6 months, mean UDVA (logMAR) increased from 0.26 preoperatively to −0.01 (P<0.001) while mean CDVA remained unchanged. Mean VTICL misalignment from the preoperative target axis was 5.3° and mean vault was 1385 μm. In the initial phase of the study, 2 VTICL had to be exchanged due to oversizing.Conclusion: Piggy-back low power VTICL can efficaciously correct residual refractive error after mIOL implantation and significantly increase UDVA. Advantages of this novel surgical approach include: VTICL availability in small diopter steps, no significant surgical-induced astigmatism, atraumatic and reversible procedure.Keywords: multifocal intraocular lens, ICL, Visian Implantable Collamer Lens®; piggy-back, add-on, residual refractive error  Duncker GIWSasse ACDuncker TDove Medical Pressarticlemultifocal intraocular lensiclimplantable collamer lenspiggy-backadd-onresidual refractive errorOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 1689-1702 (2019)
institution DOAJ
collection DOAJ
language EN
topic multifocal intraocular lens
icl
implantable collamer lens
piggy-back
add-on
residual refractive error
Ophthalmology
RE1-994
spellingShingle multifocal intraocular lens
icl
implantable collamer lens
piggy-back
add-on
residual refractive error
Ophthalmology
RE1-994
Duncker GIW
Sasse AC
Duncker T
A prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation
description Gernot IW Duncker, Anna C Sasse, Tobias Duncker Institute of Ophthalmology, Halle, GermanyCorrespondence: Tobias DunckerInstitute of Ophthalmology, Rathenauplatz 12, 06114 Halle, GermanyEmail tobias.duncker@augenheilkunde.dePurpose: To assess whether residual refractive error after in-the-bag multifocal intraocular lens (mIOL) implantation can efficaciously and safely be corrected with a piggy-back low power Visian Toric Implantable Collamer Lens® (VTICL, STAAR Surgical) placed in the ciliary sulcus.Patients and methods: Twenty-four eyes of 23 patients (mean age: 57.5 years) with diminished uncorrected distance visual acuity (UDVA) of ≥2 lines due to residual refractive error after mIOL implantation were included in the study. VTICL size was calculated using the standard STAAR Visian ICL calculation software for phakic eyes. Postoperative study visits (1 day, 1 week, 3 months and 6 months after VTICL implantation) included UDVA, corrected distance visual acuity (CDVA), VTICL axis alignment, vault (space between mIOL and VTICL), IOP and documentation of adverse events.Results: At 6 months, mean UDVA (logMAR) increased from 0.26 preoperatively to −0.01 (P<0.001) while mean CDVA remained unchanged. Mean VTICL misalignment from the preoperative target axis was 5.3° and mean vault was 1385 μm. In the initial phase of the study, 2 VTICL had to be exchanged due to oversizing.Conclusion: Piggy-back low power VTICL can efficaciously correct residual refractive error after mIOL implantation and significantly increase UDVA. Advantages of this novel surgical approach include: VTICL availability in small diopter steps, no significant surgical-induced astigmatism, atraumatic and reversible procedure.Keywords: multifocal intraocular lens, ICL, Visian Implantable Collamer Lens®; piggy-back, add-on, residual refractive error  
format article
author Duncker GIW
Sasse AC
Duncker T
author_facet Duncker GIW
Sasse AC
Duncker T
author_sort Duncker GIW
title A prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation
title_short A prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation
title_full A prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation
title_fullStr A prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation
title_full_unstemmed A prospective pilot study using a low power piggy-back toric implantable Collamer lens to correct residual refractive error after multifocal IOL implantation
title_sort prospective pilot study using a low power piggy-back toric implantable collamer lens to correct residual refractive error after multifocal iol implantation
publisher Dove Medical Press
publishDate 2019
url https://doaj.org/article/4dc88f7293414ae6925fac2168fc7fd9
work_keys_str_mv AT dunckergiw aprospectivepilotstudyusingalowpowerpiggybacktoricimplantablecollamerlenstocorrectresidualrefractiveerroraftermultifocaliolimplantation
AT sasseac aprospectivepilotstudyusingalowpowerpiggybacktoricimplantablecollamerlenstocorrectresidualrefractiveerroraftermultifocaliolimplantation
AT dunckert aprospectivepilotstudyusingalowpowerpiggybacktoricimplantablecollamerlenstocorrectresidualrefractiveerroraftermultifocaliolimplantation
AT dunckergiw prospectivepilotstudyusingalowpowerpiggybacktoricimplantablecollamerlenstocorrectresidualrefractiveerroraftermultifocaliolimplantation
AT sasseac prospectivepilotstudyusingalowpowerpiggybacktoricimplantablecollamerlenstocorrectresidualrefractiveerroraftermultifocaliolimplantation
AT dunckert prospectivepilotstudyusingalowpowerpiggybacktoricimplantablecollamerlenstocorrectresidualrefractiveerroraftermultifocaliolimplantation
_version_ 1718402593017823232