Intraocular lens intracapsular fixation with unilateral loop suture for 180 degree Zinn’s zonule dialysis
Yukihiko Suzuki, Kobu Adachi, Yoshihiro Jinnai, Kaori Suzuki, Mitsuru Nakazawa Department of Ophthalmology, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori, Japan Abstract: We developed intraocular lens (IOL) fixation procedure that only uses one suture during Zinn’s zo...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://doaj.org/article/4e500f478949441ab5cca52c0a47dd97 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:4e500f478949441ab5cca52c0a47dd97 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:4e500f478949441ab5cca52c0a47dd972021-12-02T03:24:38ZIntraocular lens intracapsular fixation with unilateral loop suture for 180 degree Zinn’s zonule dialysis1177-5483https://doaj.org/article/4e500f478949441ab5cca52c0a47dd972018-10-01T00:00:00Zhttps://www.dovepress.com/intraocular-lens-intracapsular-fixation-with-unilateral-loop-suture-fo-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Yukihiko Suzuki, Kobu Adachi, Yoshihiro Jinnai, Kaori Suzuki, Mitsuru Nakazawa Department of Ophthalmology, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori, Japan Abstract: We developed intraocular lens (IOL) fixation procedure that only uses one suture during Zinn’s zonule dialysis portion of the combined surgery for IOL intracapsular fixation and unilateral loop suture for preserving the lens capsule. We treated 15 eyes in 15 patients which were confirmed to have almost 180° zonular dialysis during cataract surgery. After removing the lens, a scleral flap was created on the dialysis side. A straight needle for suturing was then inserted into the anterior chamber from the opposite side of the dialysis. The needle was used to attach the equatorial segment of the capsule on the dialysis side from the inside to the outside and then pull the suture thread under the scleral flap. After the thread was bound to a preceding loop of IOL, the IOL was inserted into the bag. Our procedure was found to be simple and less invasive, as our technique required no vitrectomy to be performed. Keywords: intraocular lens, zonular dialysis, IOL scleral suturing, cataract surgerySuzuki YAdachi KJinnai YSuzuki KNakazawa MDove Medical Pressarticleintraocular lenszonular dialysisIOL scleral suturingcataract surgeryOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 2087-2093 (2018) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
intraocular lens zonular dialysis IOL scleral suturing cataract surgery Ophthalmology RE1-994 |
spellingShingle |
intraocular lens zonular dialysis IOL scleral suturing cataract surgery Ophthalmology RE1-994 Suzuki Y Adachi K Jinnai Y Suzuki K Nakazawa M Intraocular lens intracapsular fixation with unilateral loop suture for 180 degree Zinn’s zonule dialysis |
description |
Yukihiko Suzuki, Kobu Adachi, Yoshihiro Jinnai, Kaori Suzuki, Mitsuru Nakazawa Department of Ophthalmology, Hirosaki University Graduate School of Medicine, Hirosaki, Aomori, Japan Abstract: We developed intraocular lens (IOL) fixation procedure that only uses one suture during Zinn’s zonule dialysis portion of the combined surgery for IOL intracapsular fixation and unilateral loop suture for preserving the lens capsule. We treated 15 eyes in 15 patients which were confirmed to have almost 180° zonular dialysis during cataract surgery. After removing the lens, a scleral flap was created on the dialysis side. A straight needle for suturing was then inserted into the anterior chamber from the opposite side of the dialysis. The needle was used to attach the equatorial segment of the capsule on the dialysis side from the inside to the outside and then pull the suture thread under the scleral flap. After the thread was bound to a preceding loop of IOL, the IOL was inserted into the bag. Our procedure was found to be simple and less invasive, as our technique required no vitrectomy to be performed. Keywords: intraocular lens, zonular dialysis, IOL scleral suturing, cataract surgery |
format |
article |
author |
Suzuki Y Adachi K Jinnai Y Suzuki K Nakazawa M |
author_facet |
Suzuki Y Adachi K Jinnai Y Suzuki K Nakazawa M |
author_sort |
Suzuki Y |
title |
Intraocular lens intracapsular fixation with unilateral loop suture for 180 degree Zinn’s zonule dialysis |
title_short |
Intraocular lens intracapsular fixation with unilateral loop suture for 180 degree Zinn’s zonule dialysis |
title_full |
Intraocular lens intracapsular fixation with unilateral loop suture for 180 degree Zinn’s zonule dialysis |
title_fullStr |
Intraocular lens intracapsular fixation with unilateral loop suture for 180 degree Zinn’s zonule dialysis |
title_full_unstemmed |
Intraocular lens intracapsular fixation with unilateral loop suture for 180 degree Zinn’s zonule dialysis |
title_sort |
intraocular lens intracapsular fixation with unilateral loop suture for 180 degree zinn’s zonule dialysis |
publisher |
Dove Medical Press |
publishDate |
2018 |
url |
https://doaj.org/article/4e500f478949441ab5cca52c0a47dd97 |
work_keys_str_mv |
AT suzukiy intraocularlensintracapsularfixationwithunilateralloopsuturefor180degreezinnrsquoszonuledialysis AT adachik intraocularlensintracapsularfixationwithunilateralloopsuturefor180degreezinnrsquoszonuledialysis AT jinnaiy intraocularlensintracapsularfixationwithunilateralloopsuturefor180degreezinnrsquoszonuledialysis AT suzukik intraocularlensintracapsularfixationwithunilateralloopsuturefor180degreezinnrsquoszonuledialysis AT nakazawam intraocularlensintracapsularfixationwithunilateralloopsuturefor180degreezinnrsquoszonuledialysis |
_version_ |
1718401791985451008 |