Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model

Abstract Solid fusion at the bone-implant interface (BII) is considered one of the indicators of a satisfactory clinical outcome for spine surgery. Although the mechanical and physical properties of nanohydroxyapatite/polyamide66 (n-HA/PA66) offers many advantages, the results of long-term follow-up...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Weiyang Zhong, Jianxiao Li, Chenbo Hu, Zhengxue Quan, Dianming Jiang
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/4e58996ed99442b0953fe1e0368f1553
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:4e58996ed99442b0953fe1e0368f1553
record_format dspace
spelling oai:doaj.org-article:4e58996ed99442b0953fe1e0368f15532021-12-02T18:01:40ZEnhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model10.1038/s41598-021-99494-42045-2322https://doaj.org/article/4e58996ed99442b0953fe1e0368f15532021-10-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-99494-4https://doaj.org/toc/2045-2322Abstract Solid fusion at the bone-implant interface (BII) is considered one of the indicators of a satisfactory clinical outcome for spine surgery. Although the mechanical and physical properties of nanohydroxyapatite/polyamide66 (n-HA/PA66) offers many advantages, the results of long-term follow-up for BIIs remain limited. This study aimed to improve the BII of n-HA/PA66 by applying plasma-sprayed titanium (PST) and assessing the mechanical and histological properties. After the PST coating was applied to n-HA/PA66 implants, the coating had uneven, porous surfaces. The compression results were not significantly different between the two groups. The micro-CT results demonstrated that at 6 weeks and 12 weeks, the bone volume (BV), BV/tissue volume (TV) and trabecular number (Tb.N) values of the n-HA/PA66-PST group were significantly higher than those of the n-HA/PA66 group. The results of undecalcified bone slicing showed that more new bone appeared to form around n-HA/PA66-PST implant than around n-HA/PA66 implant. The bone-implant contact (BIC) and push-out test results of the n-HA/PA66-PST group were better than those of the n-HA/PA66 group. In conclusion, after PST coating, direct and additional new bone-to-implant bonding could be achieved, improving the BII of n-HA/PA66 implants. The n-HA/PA66-PST implants could be promising for repair purposes.Weiyang ZhongJianxiao LiChenbo HuZhengxue QuanDianming JiangNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Weiyang Zhong
Jianxiao Li
Chenbo Hu
Zhengxue Quan
Dianming Jiang
Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
description Abstract Solid fusion at the bone-implant interface (BII) is considered one of the indicators of a satisfactory clinical outcome for spine surgery. Although the mechanical and physical properties of nanohydroxyapatite/polyamide66 (n-HA/PA66) offers many advantages, the results of long-term follow-up for BIIs remain limited. This study aimed to improve the BII of n-HA/PA66 by applying plasma-sprayed titanium (PST) and assessing the mechanical and histological properties. After the PST coating was applied to n-HA/PA66 implants, the coating had uneven, porous surfaces. The compression results were not significantly different between the two groups. The micro-CT results demonstrated that at 6 weeks and 12 weeks, the bone volume (BV), BV/tissue volume (TV) and trabecular number (Tb.N) values of the n-HA/PA66-PST group were significantly higher than those of the n-HA/PA66 group. The results of undecalcified bone slicing showed that more new bone appeared to form around n-HA/PA66-PST implant than around n-HA/PA66 implant. The bone-implant contact (BIC) and push-out test results of the n-HA/PA66-PST group were better than those of the n-HA/PA66 group. In conclusion, after PST coating, direct and additional new bone-to-implant bonding could be achieved, improving the BII of n-HA/PA66 implants. The n-HA/PA66-PST implants could be promising for repair purposes.
format article
author Weiyang Zhong
Jianxiao Li
Chenbo Hu
Zhengxue Quan
Dianming Jiang
author_facet Weiyang Zhong
Jianxiao Li
Chenbo Hu
Zhengxue Quan
Dianming Jiang
author_sort Weiyang Zhong
title Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
title_short Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
title_full Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
title_fullStr Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
title_full_unstemmed Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
title_sort enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/4e58996ed99442b0953fe1e0368f1553
work_keys_str_mv AT weiyangzhong enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel
AT jianxiaoli enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel
AT chenbohu enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel
AT zhengxuequan enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel
AT dianmingjiang enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel
_version_ 1718378986885611520