Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model
Abstract Solid fusion at the bone-implant interface (BII) is considered one of the indicators of a satisfactory clinical outcome for spine surgery. Although the mechanical and physical properties of nanohydroxyapatite/polyamide66 (n-HA/PA66) offers many advantages, the results of long-term follow-up...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/4e58996ed99442b0953fe1e0368f1553 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:4e58996ed99442b0953fe1e0368f1553 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:4e58996ed99442b0953fe1e0368f15532021-12-02T18:01:40ZEnhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model10.1038/s41598-021-99494-42045-2322https://doaj.org/article/4e58996ed99442b0953fe1e0368f15532021-10-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-99494-4https://doaj.org/toc/2045-2322Abstract Solid fusion at the bone-implant interface (BII) is considered one of the indicators of a satisfactory clinical outcome for spine surgery. Although the mechanical and physical properties of nanohydroxyapatite/polyamide66 (n-HA/PA66) offers many advantages, the results of long-term follow-up for BIIs remain limited. This study aimed to improve the BII of n-HA/PA66 by applying plasma-sprayed titanium (PST) and assessing the mechanical and histological properties. After the PST coating was applied to n-HA/PA66 implants, the coating had uneven, porous surfaces. The compression results were not significantly different between the two groups. The micro-CT results demonstrated that at 6 weeks and 12 weeks, the bone volume (BV), BV/tissue volume (TV) and trabecular number (Tb.N) values of the n-HA/PA66-PST group were significantly higher than those of the n-HA/PA66 group. The results of undecalcified bone slicing showed that more new bone appeared to form around n-HA/PA66-PST implant than around n-HA/PA66 implant. The bone-implant contact (BIC) and push-out test results of the n-HA/PA66-PST group were better than those of the n-HA/PA66 group. In conclusion, after PST coating, direct and additional new bone-to-implant bonding could be achieved, improving the BII of n-HA/PA66 implants. The n-HA/PA66-PST implants could be promising for repair purposes.Weiyang ZhongJianxiao LiChenbo HuZhengxue QuanDianming JiangNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Weiyang Zhong Jianxiao Li Chenbo Hu Zhengxue Quan Dianming Jiang Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model |
description |
Abstract Solid fusion at the bone-implant interface (BII) is considered one of the indicators of a satisfactory clinical outcome for spine surgery. Although the mechanical and physical properties of nanohydroxyapatite/polyamide66 (n-HA/PA66) offers many advantages, the results of long-term follow-up for BIIs remain limited. This study aimed to improve the BII of n-HA/PA66 by applying plasma-sprayed titanium (PST) and assessing the mechanical and histological properties. After the PST coating was applied to n-HA/PA66 implants, the coating had uneven, porous surfaces. The compression results were not significantly different between the two groups. The micro-CT results demonstrated that at 6 weeks and 12 weeks, the bone volume (BV), BV/tissue volume (TV) and trabecular number (Tb.N) values of the n-HA/PA66-PST group were significantly higher than those of the n-HA/PA66 group. The results of undecalcified bone slicing showed that more new bone appeared to form around n-HA/PA66-PST implant than around n-HA/PA66 implant. The bone-implant contact (BIC) and push-out test results of the n-HA/PA66-PST group were better than those of the n-HA/PA66 group. In conclusion, after PST coating, direct and additional new bone-to-implant bonding could be achieved, improving the BII of n-HA/PA66 implants. The n-HA/PA66-PST implants could be promising for repair purposes. |
format |
article |
author |
Weiyang Zhong Jianxiao Li Chenbo Hu Zhengxue Quan Dianming Jiang |
author_facet |
Weiyang Zhong Jianxiao Li Chenbo Hu Zhengxue Quan Dianming Jiang |
author_sort |
Weiyang Zhong |
title |
Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model |
title_short |
Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model |
title_full |
Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model |
title_fullStr |
Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model |
title_full_unstemmed |
Enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model |
title_sort |
enhancement of the bone-implant interface by applying a plasma-sprayed titanium coating on nanohydroxyapatite/polyamide66 implants in a rabbit model |
publisher |
Nature Portfolio |
publishDate |
2021 |
url |
https://doaj.org/article/4e58996ed99442b0953fe1e0368f1553 |
work_keys_str_mv |
AT weiyangzhong enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel AT jianxiaoli enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel AT chenbohu enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel AT zhengxuequan enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel AT dianmingjiang enhancementoftheboneimplantinterfacebyapplyingaplasmasprayedtitaniumcoatingonnanohydroxyapatitepolyamide66implantsinarabbitmodel |
_version_ |
1718378986885611520 |