VISCOMETRY OF NANODISPERSE MAGNETIC LIQUIDS AND LUBRICATING OILS. 2. METROLOGICAL ANALYSIS OF A DEVICE FOR RHEOLOGICAL STUDIES OF MAGNETIC NANODISPERSE LIQUID MEDIA
An analysis is carried out of the main sources of methodological errors of the magnetic rotary viscometer. The analysis allowed to improve design and to eliminate critical modes of the research. Theoretical evaluations of the systematic error of the device showed that the value of the relative measu...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | RU |
Publicado: |
Tver State University
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/4f70516b2aa14bc996143d63c492efb5 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:4f70516b2aa14bc996143d63c492efb5 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:4f70516b2aa14bc996143d63c492efb52021-12-03T08:31:54ZVISCOMETRY OF NANODISPERSE MAGNETIC LIQUIDS AND LUBRICATING OILS. 2. METROLOGICAL ANALYSIS OF A DEVICE FOR RHEOLOGICAL STUDIES OF MAGNETIC NANODISPERSE LIQUID MEDIA10.26456/pcascnn/2021.13.0562226-44422658-4360https://doaj.org/article/4f70516b2aa14bc996143d63c492efb52021-12-01T00:00:00Zhttps://physchemaspects.ru/2021/doi-10-26456-pcascnn-2021-13-056/?lang=enhttps://doaj.org/toc/2226-4442https://doaj.org/toc/2658-4360An analysis is carried out of the main sources of methodological errors of the magnetic rotary viscometer. The analysis allowed to improve design and to eliminate critical modes of the research. Theoretical evaluations of the systematic error of the device showed that the value of the relative measurement error can be brought to a value of less than 1%. The greatest contribution to the systematic error of the device is made by the instability of the temperature regime of the nanofluid under study and by the inaccuracy of determining the height of the liquid layer in contact with the measuring cylinder. The measurement of the viscosity of the reference liquids on the magnetic viscometer showed that experimental values are slightly, by about 0.9% overestimated. Calibration of the device on various reference liquids allowed reducing the total measurement error down to tenths of a percent. The magnetic rotary viscometer can be used in non-standard scientific studies of the structure and rheological characteristics of nanofluids, for operational control of the processes of synthesis of magnetic liquids and certification of magnetic nanofluids intended for technical use.A.N. BolotovO.O. NovikovaV.V. MeshkovTver State Universityarticlemagnetic nanofluidrheologyviscometershear stressshear ratePhysical and theoretical chemistryQD450-801RUФизико-химические аспекты изучения кластеров, наноструктур и наноматериалов, Iss 13, Pp 56-64 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
RU |
topic |
magnetic nanofluid rheology viscometer shear stress shear rate Physical and theoretical chemistry QD450-801 |
spellingShingle |
magnetic nanofluid rheology viscometer shear stress shear rate Physical and theoretical chemistry QD450-801 A.N. Bolotov O.O. Novikova V.V. Meshkov VISCOMETRY OF NANODISPERSE MAGNETIC LIQUIDS AND LUBRICATING OILS. 2. METROLOGICAL ANALYSIS OF A DEVICE FOR RHEOLOGICAL STUDIES OF MAGNETIC NANODISPERSE LIQUID MEDIA |
description |
An analysis is carried out of the main sources of methodological errors of the magnetic rotary viscometer. The analysis allowed to improve design and to eliminate critical modes of the research. Theoretical evaluations of the systematic error of the device showed that the value of the relative measurement error can be brought to a value of less than 1%. The greatest contribution to the systematic error of the device is made by the instability of the temperature regime of the nanofluid under study and by the inaccuracy of determining the height of the liquid layer in contact with the measuring cylinder. The measurement of the viscosity of the reference liquids on the magnetic viscometer showed that experimental values are slightly, by about 0.9% overestimated. Calibration of the device on various reference liquids allowed reducing the total measurement error down to tenths of a percent. The magnetic rotary viscometer can be used in non-standard scientific studies of the structure and rheological characteristics of nanofluids, for operational control of the processes of synthesis of magnetic liquids and certification of magnetic nanofluids intended for technical use. |
format |
article |
author |
A.N. Bolotov O.O. Novikova V.V. Meshkov |
author_facet |
A.N. Bolotov O.O. Novikova V.V. Meshkov |
author_sort |
A.N. Bolotov |
title |
VISCOMETRY OF NANODISPERSE MAGNETIC LIQUIDS AND LUBRICATING OILS. 2. METROLOGICAL ANALYSIS OF A DEVICE FOR RHEOLOGICAL STUDIES OF MAGNETIC NANODISPERSE LIQUID MEDIA |
title_short |
VISCOMETRY OF NANODISPERSE MAGNETIC LIQUIDS AND LUBRICATING OILS. 2. METROLOGICAL ANALYSIS OF A DEVICE FOR RHEOLOGICAL STUDIES OF MAGNETIC NANODISPERSE LIQUID MEDIA |
title_full |
VISCOMETRY OF NANODISPERSE MAGNETIC LIQUIDS AND LUBRICATING OILS. 2. METROLOGICAL ANALYSIS OF A DEVICE FOR RHEOLOGICAL STUDIES OF MAGNETIC NANODISPERSE LIQUID MEDIA |
title_fullStr |
VISCOMETRY OF NANODISPERSE MAGNETIC LIQUIDS AND LUBRICATING OILS. 2. METROLOGICAL ANALYSIS OF A DEVICE FOR RHEOLOGICAL STUDIES OF MAGNETIC NANODISPERSE LIQUID MEDIA |
title_full_unstemmed |
VISCOMETRY OF NANODISPERSE MAGNETIC LIQUIDS AND LUBRICATING OILS. 2. METROLOGICAL ANALYSIS OF A DEVICE FOR RHEOLOGICAL STUDIES OF MAGNETIC NANODISPERSE LIQUID MEDIA |
title_sort |
viscometry of nanodisperse magnetic liquids and lubricating oils. 2. metrological analysis of a device for rheological studies of magnetic nanodisperse liquid media |
publisher |
Tver State University |
publishDate |
2021 |
url |
https://doaj.org/article/4f70516b2aa14bc996143d63c492efb5 |
work_keys_str_mv |
AT anbolotov viscometryofnanodispersemagneticliquidsandlubricatingoils2metrologicalanalysisofadeviceforrheologicalstudiesofmagneticnanodisperseliquidmedia AT oonovikova viscometryofnanodispersemagneticliquidsandlubricatingoils2metrologicalanalysisofadeviceforrheologicalstudiesofmagneticnanodisperseliquidmedia AT vvmeshkov viscometryofnanodispersemagneticliquidsandlubricatingoils2metrologicalanalysisofadeviceforrheologicalstudiesofmagneticnanodisperseliquidmedia |
_version_ |
1718373388394692608 |