Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients

Simin Asadian,1 Alireza Khatony,1 Gholamreza Moradi,2 Alireza Abdi,1 Mansour Rezaei,3 1Nursing and Midwifery School, Kermanshah University of Medical Sciences, 2Department of Anesthesiology, 3Biostatistics & Epidemiology Department, Kermanshah University of Medical Sciences, Kermans...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Asadian S, Khatony A, Moradi G, Abdi A, Rezaei M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://doaj.org/article/50444da1fd6c4beebc2cfce5a9a4cd93
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:50444da1fd6c4beebc2cfce5a9a4cd93
record_format dspace
spelling oai:doaj.org-article:50444da1fd6c4beebc2cfce5a9a4cd932021-12-02T07:54:17ZAccuracy and precision of four common peripheral temperature measurement methods in intensive care patients1179-1470https://doaj.org/article/50444da1fd6c4beebc2cfce5a9a4cd932016-09-01T00:00:00Zhttps://www.dovepress.com/accuracy-and-precision-of-four-common-peripheral-temperature-measureme-peer-reviewed-article-MDERhttps://doaj.org/toc/1179-1470Simin Asadian,1 Alireza Khatony,1 Gholamreza Moradi,2 Alireza Abdi,1 Mansour Rezaei,3 1Nursing and Midwifery School, Kermanshah University of Medical Sciences, 2Department of Anesthesiology, 3Biostatistics & Epidemiology Department, Kermanshah University of Medical Sciences, Kermanshah, Iran Introduction: An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. Methods: In this observational prospective study, 237 patients were recruited from the intensive care unit of Imam Ali Hospital of Kermanshah. The patients’ body temperatures were measured by four peripheral methods; oral, axillary, tympanic, and forehead along with a standard central nasopharyngeal measurement. After data collection, the results were analyzed by paired t-test, kappa coefficient, receiver operating characteristic curve, and using Statistical Package for the Social Sciences, version 19, software. Results: There was a significant meaningful correlation between all the peripheral methods when compared with the central measurement (P<0.001). Kappa coefficients showed good agreement between the temperatures of right and left tympanic membranes and the standard central nasopharyngeal measurement (88%). Paired t-test demonstrated an acceptable precision with forehead (P=0.132), left (P=0.18) and right (P=0.318) tympanic membranes, oral (P=1.00), and axillary (P=1.00) methods. Sensitivity and specificity of both the left and right tympanic membranes were more than for other methods. Conclusion: The tympanic and forehead methods had the highest and lowest accuracy for measuring body temperature, respectively. It is recommended to use the tympanic method (right and left) for assessing a patient’s body temperature in the intensive care units because of high accuracy and acceptable precision. Keywords: body temperature, thermometers, intensive care units, sensitivity and specificity, tympanic membraneAsadian SKhatony AMoradi GAbdi ARezaei MDove Medical Pressarticlebody temperatureThermometersIntensive Care UnitsSensitivity and Specificitytympanic membraneFeverMedical technologyR855-855.5ENMedical Devices: Evidence and Research, Vol Volume 9, Pp 301-308 (2016)
institution DOAJ
collection DOAJ
language EN
topic body temperature
Thermometers
Intensive Care Units
Sensitivity and Specificity
tympanic membrane
Fever
Medical technology
R855-855.5
spellingShingle body temperature
Thermometers
Intensive Care Units
Sensitivity and Specificity
tympanic membrane
Fever
Medical technology
R855-855.5
Asadian S
Khatony A
Moradi G
Abdi A
Rezaei M
Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients
description Simin Asadian,1 Alireza Khatony,1 Gholamreza Moradi,2 Alireza Abdi,1 Mansour Rezaei,3 1Nursing and Midwifery School, Kermanshah University of Medical Sciences, 2Department of Anesthesiology, 3Biostatistics & Epidemiology Department, Kermanshah University of Medical Sciences, Kermanshah, Iran Introduction: An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. Methods: In this observational prospective study, 237 patients were recruited from the intensive care unit of Imam Ali Hospital of Kermanshah. The patients’ body temperatures were measured by four peripheral methods; oral, axillary, tympanic, and forehead along with a standard central nasopharyngeal measurement. After data collection, the results were analyzed by paired t-test, kappa coefficient, receiver operating characteristic curve, and using Statistical Package for the Social Sciences, version 19, software. Results: There was a significant meaningful correlation between all the peripheral methods when compared with the central measurement (P<0.001). Kappa coefficients showed good agreement between the temperatures of right and left tympanic membranes and the standard central nasopharyngeal measurement (88%). Paired t-test demonstrated an acceptable precision with forehead (P=0.132), left (P=0.18) and right (P=0.318) tympanic membranes, oral (P=1.00), and axillary (P=1.00) methods. Sensitivity and specificity of both the left and right tympanic membranes were more than for other methods. Conclusion: The tympanic and forehead methods had the highest and lowest accuracy for measuring body temperature, respectively. It is recommended to use the tympanic method (right and left) for assessing a patient’s body temperature in the intensive care units because of high accuracy and acceptable precision. Keywords: body temperature, thermometers, intensive care units, sensitivity and specificity, tympanic membrane
format article
author Asadian S
Khatony A
Moradi G
Abdi A
Rezaei M
author_facet Asadian S
Khatony A
Moradi G
Abdi A
Rezaei M
author_sort Asadian S
title Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients
title_short Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients
title_full Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients
title_fullStr Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients
title_full_unstemmed Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients
title_sort accuracy and precision of four common peripheral temperature measurement methods in intensive care patients
publisher Dove Medical Press
publishDate 2016
url https://doaj.org/article/50444da1fd6c4beebc2cfce5a9a4cd93
work_keys_str_mv AT asadians accuracyandprecisionoffourcommonperipheraltemperaturemeasurementmethodsinintensivecarepatients
AT khatonya accuracyandprecisionoffourcommonperipheraltemperaturemeasurementmethodsinintensivecarepatients
AT moradig accuracyandprecisionoffourcommonperipheraltemperaturemeasurementmethodsinintensivecarepatients
AT abdia accuracyandprecisionoffourcommonperipheraltemperaturemeasurementmethodsinintensivecarepatients
AT rezaeim accuracyandprecisionoffourcommonperipheraltemperaturemeasurementmethodsinintensivecarepatients
_version_ 1718399102189830144